Effects of sodium hypochlorite and ethylenediaminetetraacetic acid on rotary nickel-titanium instruments evaluated using atomic force microscopy

被引:39
|
作者
Ametrano, G. [1 ]
D'Anto, V. [1 ]
Di Caprio, M. P. [1 ]
Simeone, M. [1 ]
Rengo, S. [1 ]
Spagnuolo, G. [1 ]
机构
[1] Univ Naples Federico II, Dept Oral & Maxillofacial Sci, Naples, Italy
关键词
atomic force microscopy; EDTA; NaOCl; NiTi; ENDODONTIC INSTRUMENTS; CYCLIC FATIGUE; FRACTURE PROPERTIES; STAINLESS-STEEL; CORROSION; SURFACE; RESISTANCE; DEFECTS; TORQUE; FILES;
D O I
10.1111/j.1365-2591.2010.01799.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
P>Aim To use atomic force microscopy (AFM) to evaluate the effects of sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA) on the surface characteristics of ProTaper rotary nickel-titanium instruments. Methodology A total of twenty ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) instruments (S1, S2, F1, F2) were divided into five groups: no immersion, immersion in 5.25% NaOCl for 5 or 10 min and immersion in 17% EDTA for 5 or 10 min. Twenty surface areas along 3- mm sections at the tip of the files (perfect squares of 1 x 1 mu m) were analysed by AFM operating in contact mode under ambient conditions. Three-dimensional images (400 x 400 lines) were processed using Gwyddion software, and the roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova and paired samples t-test. Results Three-dimensional AFM images of the surface of ProTaper instruments, including new and those immersed in NaOCl and EDTA solutions, revealed topographic irregularities at the nanometric scale. RMS and Ra values of instruments treated with NaOCl and EDTA solutions were statistically higher than that of the new ones (P < 0.05). Conclusions Atomic force microscopy three-dimensional images and roughness values indicated that short-term contact between NaOCl and EDTA endodontic irrigants and ProTaper instruments caused alterations in the surface of instruments.
引用
收藏
页码:203 / 209
页数:7
相关论文
共 50 条
  • [1] Structural effects of sodium hypochlorite solution on RaCe rotary nickel-titanium instruments: an atomic force microscopy study
    Topuz, Ozgur
    Aydin, Cumhur
    Uzun, Ozgur
    Inan, Ugur
    Alacam, Tayfun
    Tunca, Yasar M.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (05): : 661 - 665
  • [2] The corrosion of nickel-titanium rotary endodontic instruments in sodium hypochlorite
    Novoa, X. R.
    Martin-Biedma, B.
    Varela-Patino, P.
    Collazo, A.
    Macias-Luaces, A.
    Cantatore, G.
    Perez, M. C.
    Magan-Munoz, F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (01) : 36 - 44
  • [3] Effects of sodium hypochlorite on nickel-titanium Lightspeed® instruments
    Busslinger, A
    Sener, B
    Barbakow, F
    INTERNATIONAL ENDODONTIC JOURNAL, 1998, 31 (04) : 290 - 294
  • [4] Effects of sodium hypochlorite on corrosion of the rotary nickel-titanium endodontic instruments - SEM analysis
    Jovanovic-Medojevic, Milica
    Neskovic, Jelena
    Popovic-Bajic, Marijana
    Stratimirovic, Dorde
    Zivkovic, Slavoljub
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2022, 150 (5-6) : 254 - 260
  • [5] Influence of sodium hypochlorite on mechanical properties of K3 nickel-titanium rotary instruments
    Galvao Barbosa, Fabiola Ormiga
    da Cunha Ponciano Gomes, Jose Antonio
    Pimenta de Araujo, Marcos Cesar
    JOURNAL OF ENDODONTICS, 2007, 33 (08) : 982 - 985
  • [6] Effects of Sodium Hypochlorite Concentration and Temperature on the Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Rotary Instruments
    Alfawaz, Hussam
    Alqedairi, Abdullah
    Alsharekh, Hala
    Almuzaini, Eman
    Alzahrani, Shand
    Jamleh, Ahmed
    JOURNAL OF ENDODONTICS, 2018, 44 (10) : 1563 - 1566
  • [7] Chemical Analysis of Nickel-Titanium Rotary Instruments with and without Electropolishing after Cleaning Procedures with Sodium Hypochlorite
    Bonaccorso, Antonio
    Schaefer, Edgar
    Condorelli, Guglielmo Guido
    Cantatore, Giuseppe
    Tripi, Teresa Roberta
    JOURNAL OF ENDODONTICS, 2008, 34 (11) : 1391 - 1395
  • [8] Pitting corrosion resistance of nickel-titanium rotary instruments with different surface treatments in seventeen percent ethylenediaminetetraacetic acid and sodium chloride solutions
    Bonaccorso, Antonio
    Tripi, Teresa Roberta
    Rondelli, Gianni
    Condorelli, Guglielmo Guido
    Cantatore, Giuseppe
    Schaefer, Edgar
    JOURNAL OF ENDODONTICS, 2008, 34 (02) : 208 - 211
  • [9] Effect of sodium hypochlorite on conventional and heat-treated nickel-titanium endodontic rotary instruments - An in vitro study
    Lin, Jack Han-Hsing
    Karabucak, Bekir
    Lee, Su-Min
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (02) : 738 - 743
  • [10] Wear of nickel-titanium lightspeed instruments evaluated by scanning electron microscopy
    Eggert, C
    Peters, O
    Barbakow, F
    JOURNAL OF ENDODONTICS, 1999, 25 (07) : 494 - 497