Analytical validation of microdialysis analyzer for monitoring glucose, lactate and pyruvate in cerebral microdialysates

被引:14
|
作者
Tholance, Yannick [1 ]
Barcelos, Gleicy [2 ,3 ]
Quadrio, Isabelle [1 ]
Renaud, Bernard [1 ]
Dallier, Frederic [4 ]
Perret-Liaudet, Armand [1 ]
机构
[1] HCL, Ctr Biol & Pathol Est, Neurobiol Lab, Lyon, France
[2] HUG, Dept Anesthesiol Phannacol & Soins Intensifs, Geneva, Switzerland
[3] CNRS, Lab Neurophormacol EAC 5006, Lyon, France
[4] HCL, Hop Neurol & Neurochirurg Pierre Wertheimer, Serv Anesthesie & Reanimat, Lyon, France
关键词
Cerebral microdialysis; Glucose; Lactate/pyruvate ratio; Analytical validation; Brain injury; ANEURYSMAL SUBARACHNOID HEMORRHAGE; CRITICALLY-ILL PATIENTS; INTRACEREBRAL MICRODIALYSIS; BIOLOGICAL VARIATION; NEUROLOGICAL DEFICITS; BEDSIDE MICRODIALYSIS; STATUS EPILEPTICUS; CONTROLLED-TRIAL; AMINO-ACIDS; PHARMACOKINETICS;
D O I
10.1016/j.cca.2010.12.025
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Cerebral microdialysis is a valuable tool for neurochemical monitoring of acute brain injury. We performed an independent analytical validation of glucose, lactate and pyruvate methods on the new ISCUSflex new analyzer developed by CMA Microdialysis. Methods: Evaluation of analytical parameters included limit of detection, limit of quantification, linearity, intra- and inter-assay imprecision expressed as the coefficient of variation (CV), recovery, inter-sample and inter-reagent contamination, drug and bilirubin interferences, sample stability, method comparison. Results: Linearity ranges were 0.1-25 mmol/L, 0.2-12 mmol/L and 19-1500 mu mol/L for glucose, lactate and pyruvate respectively. For critical threshold, intra- and inter-assay CVs were 3.1/4.5% for glucose (1 mmol/L), 3.5/4% for lactate (4 mmol/L) and 3.3/4.3% for pyruvate (100 mu mol/L). Inter-assay CVs for lactate/pyruvate (LPR) and lactate/glucose (LGR) ratios were 5.9% and 6.0% respectively. For glucose, lactate, pyruvate. LPR and LGR, the reference change values (RCV) were 20%, 26%, 20%, 27% and 28% respectively. Practically, variations below 27% between two successive LPR values could not be interpreted as significant. Conclusion: These data prove that ISCUSflex has the qualities required for clinical application in neuro-intensive care. Correct clinical interpretation of data need the implementation of a strict quality control program and strong cooperation between clinicians and biologists. (C) 2010 Elsevier B.V. All rights reserved.