A Versatile FG-MOSFET Inverter Design for X-Ray Radiation Dosimetry Applications

被引:1
|
作者
Yadegari, Behzad [1 ]
Roy, Langis [2 ]
Ghaffar, Farhan A. [3 ]
机构
[1] Carleton Univ, Dept Elect, Ottawa, ON K1S 5B6, Canada
[2] Ontario Tech Univ, Fac Engn & Appl Sci, Oshawa, ON L1H 7K4, Canada
[3] Lakehead Univ, Dept Elect Engn, Ontario, ON L4M 3X9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Blood; Inverters; Radiation effects; MOSFET; Biomedical measurement; Radio frequency; Dosimetry; X-ray; gamma ray; radiation dosimeter; sensor; blood irradiator; blood bag;
D O I
10.1109/TBCAS.2021.3111784
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel inverter-based digital floating-gate MOSFET sensor design for commercial X-ray dosimetry is presented. The biomedical healthcare industry sterilizes blood products for storage purposes using Gamma and X-ray radiations. This requires an ultra-low-power dosimeter that ensures irradiation does not exceed the maximum allowable 50 Gy while providing the required minimum levels of 25 Gy. In this work, minimum-sized MOS transistor devices are employed in an inverter configuration, eliminating the continuous flow of current and reducing power consumption significantly. Maximum measured currents, which flow only during the transition period, are in the nA range, compared to continuous currents of conventional sensor designs in the mu A range. Final measured results show the viability of the proposed design for radiation dosimetry applications.
引用
收藏
页码:1008 / 1016
页数:9
相关论文
共 50 条
  • [1] MOSFET dosimetry of an X-ray microbeam
    Rosenfeld, A.B.
    Kaplan, G.I.
    Kron, T.
    Allen, B.J.
    Dilmanian, A.
    Orion, I.
    Ren, B.
    Lerch, M.L.F.
    Holmes-Siedle, A.
    IEEE Transactions on Nuclear Science, 1999, 46 (6 I): : 1774 - 1780
  • [2] MOSFET dosimetry of an X-ray microbeam.
    Rosenfeld, AB
    Kaplan, GI
    Kron, T
    Allen, BJ
    Dilmanian, A
    Orion, I
    Ren, B
    Lerch, MLF
    Holmes-Siedle, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 1774 - 1780
  • [3] Improved spatial resolution by MOSFET dosimetry of an x-ray microbeam
    Kaplan, GI
    Rosenfeld, AB
    Allen, BJ
    Booth, JT
    Carolan, MG
    Holmes-Siedle, A
    MEDICAL PHYSICS, 2000, 27 (01) : 239 - 244
  • [4] Visualized X-ray Dosimetry for Multienvironment Applications
    Lu, Lan
    Peng, Songcheng
    Zhao, Lei
    Zhang, Meiguang
    Xiao, Jianqiang
    Wen, Hongyu
    Zhang, Peng
    Yakovlev, Alexey Nikolaevich
    Qiu, Jianbei
    Yu, Xue
    Wang, Ting
    Xu, Xuhui
    NANO LETTERS, 2023, 23 (18) : 8753 - 8760
  • [5] MOSFET dosimetry in-vivo at superficial and orthovoltage x-ray energies
    T. Cheung
    M. J. Butson
    P. K. N. Yu
    Australasian Physics & Engineering Sciences in Medicine, 2003, 26 (2): : 81 - 83
  • [6] New X-Ray Radiation Sensor for Dosimetry Imaging
    Pace, Calogero
    Pikhay, Evgeny
    Santaniello, Anna
    Nemirovsky, Yael
    Roizin, Yakov
    APPLICATIONS IN ELECTRONICS PERVADING INDUSTRY, ENVIRONMENT AND SOCIETY, 2017, 409 : 123 - 132
  • [7] The versatile X-ray beamline of the Munich Compact Light Source: design, instrumentation and applications
    Guenther, Benedikt
    Gradl, Regine
    Jud, Christoph
    Eggl, Elena
    Huang, Juanjuan
    Kulpe, Stephanie
    Achterhold, Klaus
    Gleich, Bernhard
    Dierolf, Martin
    Pfeiffer, Franz
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 1395 - 1414
  • [8] Feasibility study of online high-spatial-resolution MOSFET dosimetry in static and pulsed X-ray radiation fields
    Rosenfeld, AB
    Lerch, MLF
    Kron, T
    Brauer-Krisch, E
    Bravin, A
    Holmes-Siedle, A
    Allen, BJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2061 - 2068
  • [9] Evaluation of radiation dosimeters for kilovoltage x-ray beam dosimetry
    Hill, R.
    Me, Z.
    Haque, M.
    Baldock, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2336 - 2337
  • [10] THERMOLUMINESCENT RADIATION DOSIMETRY APPLIED TO DENTAL X-RAY EXPOSURES
    HOWLEY, JR
    ROBBINS, C
    DICKINSO.MB
    HEALTH PHYSICS, 1968, 15 (02): : 181 - +