Development and Validation of a Dynamic Air Handling Unit Model, Part 2

被引:0
|
作者
Li, Shun [1 ]
Wen, Jin [1 ]
Zhou, Xiaohui [2 ]
Klaassen, Curtis J. [2 ]
机构
[1] Drexel Univ, Dept Civil Architectural & Environm Engn, Philadelphia, PA 19104 USA
[2] Iowa Energy Ctr, Energy Resource Stn, Iowa City, IA USA
来源
ASHRAE TRANSACTIONS 2010, VOL 116, PT 1 | 2010年 / 116卷
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The validation process and result of a dynamic air handling unit (AHU) model (referred to as 1312 model hereafter) are discussed in this paper The development of the 1312 model is summarized in a companion paper Strategies to validate the model using experimental data mostly from common system operations are designed. If problems were identified using system operation data, follow up component model calibration is used to mod and improve the model. A series of experiments were designed and implemented to obtain pressure resistance parameters for the supply duct system and mixing box dampers. Building operation data from winter summer, and spring seasons were used to validate the 1312 model. Good agreements were achieved between experimental data and simulation outputs for the 1312 AHU model, especially for summer and winter seasons. When using 1312 model to simulate AHU operation for spring season conditions, simulated outdoor and supply airflow rates and supply air temperature, while tracking experimental data, showed certain level of oscillation.
引用
收藏
页码:57 / +
页数:3
相关论文
共 50 条
  • [21] Development and validation of a dynamic model of an AUV
    Feng, ZP
    Allen, R
    GUIDANCE AND CONTROL OF UNDERWATER VEHICLES 2003, 2003, : 175 - 180
  • [22] IAQ and air handling unit design
    Henningson, Durham and Richardson, Inc, Dallas, United States
    HPAC Heat Piping Air Cond, 6
  • [23] Control of the outlet air temperature in an Air Handling Unit
    Brath, P
    Rasmussen, H
    Hagglund, T
    UKACC INTERNATIONAL CONFERENCE ON CONTROL '98, VOLS I&II, 1998, : 935 - 940
  • [24] DEVELOPMENT AND VALIDATION OF AN AIRPORT AIR QUALITY MODEL
    THAYER, SD
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1974, 55 (05) : 525 - 525
  • [25] Kinetic model for electrorefining, part I: Model development and validation
    Zhang, Jinsuo
    PROGRESS IN NUCLEAR ENERGY, 2014, 70 : 279 - 286
  • [26] Dynamic Model of Air Handling Units and Effect of Different Influential Factors
    Hu, Shuang
    Ding, Qiang
    Ye, Xiaoping
    Li, Peiyuan
    2016 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2016, : 654 - 658
  • [27] Heat Recovery Unit Failure Detection in Air Handling Unit
    Madhikermi, Manik
    Yousefnezhad, Narges
    Framling, Kary
    ADVANCES IN PRODUCTION MANAGEMENT SYSTEMS: SMART MANUFACTURING FOR INDUSTRY 4.0, APMS 2018, 2018, 536 : 343 - 350
  • [28] Development and experimental validation of a compressor dynamic model
    Venturini, M
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 599 - 608
  • [29] Novel Air Filtration Device for Building Air Handling Unit
    Kwon, Soon-Bark
    Kim, Seyoung
    Park, Duck-Shin
    Cho, Youngmin
    Kim, Jinho
    Kim, Myungjoon
    Kim, Taesung
    AEROSOL AND AIR QUALITY RESEARCH, 2011, 11 (05) : 570 - 577
  • [30] Analysis of exergy demand for air heating of an air handling unit
    Miseviciute, Violeta
    Valancius, Kestutis
    Motuziene, Violeta
    Rynkun, Genrika
    ENERGY EFFICIENCY, 2017, 10 (04) : 989 - 998