Measurement of intracellular pH in cultured cells by flow cytometry with BCECF-AM

被引:50
|
作者
Franck, P
Petitipain, N
Cherlet, M
Dardennes, M
Maachi, F
Schutz, B
Poisson, L
Nabet, P
机构
[1] FAC MED NANCY, LAB BIOCHIM MED 1, F-54505 VANDOEUVRE LES NANCY, FRANCE
[2] IBM CORP, F-54505 VANDOEUVRE LES NANCY, FRANCE
[3] CNRS, LAB SCI GENIE CHIM, F-54500 NANCY, FRANCE
关键词
intracellular pH; flow cytometry; BCECF; hybridoma cells; CARBOXY-SNARF-1;
D O I
10.1016/0168-1656(95)00189-1
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This study evaluates the suitability of flow cytometry with the fluorochrome BCECF for measuring the intracellular pH (pH(i)) of cultured cells, and monitors the changes in pH(i) in murine hybridoma in batch culture and chick embryo fibroblast in monolayer culture (5th passage). The technique produced highly reproducible, repeatable results. The theoretical sensitivity from the calibration curve was 0.0004 pH units. But analysis of the standard deviation of the histogram of the green/red fluorescence ratios indicated a mean sensitivity of 0.08 (0.07-0.09) pH units. Interference due to cell size, fluorochrome incorporation and esterases were minimized by establishing a calibration curve with the cells whose pH(i) was to be measured using the 525/610 nm fluorescence ratio after excitation at 488 nm. The pH(i) of exponentially growing, batch cultured hybridomas was 7.50 at the start of culture. pH(i) increased during the exponential growth phase and dropped towards cell death. The pH(i) of the chick fibroblasts in monolayer culture was 7.30.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 50 条
  • [21] Application of flow cytometry with a fluorescent dye to measurement of intracellular nitric oxide in plant cells
    Jan Kępczyński
    Danuta Cembrowska-Lech
    Planta, 2018, 248 : 279 - 291
  • [22] Application of flow cytometry with a fluorescent dye to measurement of intracellular nitric oxide in plant cells
    Kepczynski, Jan
    Cembrowska-Lech, Danuta
    PLANTA, 2018, 248 (02) : 279 - 291
  • [23] ACCURACY OF INTRACELLULAR PH MEASUREMENT WITH BCECF IN A MALPIGHIAN TUBULE - CAN THE PH(NULL) OR WEAK ACID/BASE METHOD BE USED AS A CONTROL
    VANKERKHOVE, E
    PETZEL, D
    JOURNAL OF PHYSIOLOGY-LONDON, 1995, 482P : P29 - P29
  • [24] Simultaneous detection of cell volume and intracellular pH in isolated rat duodenal cells by confocal microscopy and BCECF
    Weinlich, M
    Heydasch, U
    Mooren, F
    Starlinger, M
    RESEARCH IN EXPERIMENTAL MEDICINE, 1998, 198 (02) : 73 - 82
  • [25] THE MEASUREMENT OF INTRACELLULAR ANTIGENS AND DNA BY MULTIPARAMETRIC FLOW-CYTOMETRY
    CAMPLEJOHN, RS
    JOURNAL OF MICROSCOPY-OXFORD, 1994, 176 : 1 - 7
  • [26] PROLIFERATION AND INTRACELLULAR PH IN CULTURED PROXIMAL TUBULAR CELLS
    LARSSON, SH
    FUKUDA, Y
    KOLARE, S
    APERIA, A
    AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (03): : F697 - F704
  • [27] Measurement of intracellular calcium dynamics with Fluo-4 AM in frozen-thawed boar sperm by flow cytometry
    Fernandez-Gago, R.
    Martinez-Pastor, F.
    Gonzalez-Urdiales, R.
    Martin, D.
    Alegre, B.
    Dominguez, J. C.
    REPRODUCTION IN DOMESTIC ANIMALS, 2011, 46 : 102 - 102
  • [28] Simultaneous Measurement of Changes in Neutrophil Granulocyte Membrane Potential, Intracellular pH, and Cell Size by Multiparametric Flow Cytometry
    Stratmann, Alexander Elias Paul
    Wohlgemuth, Lisa
    Erber, Maike Elisabeth
    Bernhard, Stefan
    Hug, Stefan
    Fauler, Michael
    Vidoni, Laura
    Mohamed, Adam Omar Khalaf
    Thomass, Bertram Dietrich
    Munnich, Frederik
    Stukan, Laura
    Fohr, Karl Josef
    Mannes, Marco
    Huber-Lang, Markus Stefan
    Messerer, David Alexander Christian
    BIOMEDICINES, 2021, 9 (11)
  • [29] Live Cell Measurement of the Intracellular pH of Yeast by Flow Cytometry Using a Genetically-Encoded Fluorescent Reporter
    Triandafillou, Catherine G.
    Drummond, D. Allan
    BIO-PROTOCOL, 2020, 10 (12):
  • [30] Simultaneous measurement of water volume and pH in single cells using BCECF and fluorescence imaging microscopy
    Alvarez-Leefmans, FJ
    Herrera-Pérez, JJ
    Márquez, MS
    Blanco, VM
    BIOPHYSICAL JOURNAL, 2006, 90 (02) : 608 - 618