Motion artifact correction in ASL images: an improved automated procedure

被引:0
|
作者
Di Cataldo, Santa [1 ]
Ficarra, Elisa [1 ]
Acquaviva, Andrea [1 ]
Macii, Enrico [1 ]
机构
[1] Politecn Torino, Dept Control & Comp Engn, Turin, Italy
关键词
Image Processing; Motion artifact correction; Magnetic Resonance Imaging; fMRI; Arterial Spin Labelling;
D O I
10.1109/BIBM.2011.106
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Arterial Spin Labelling (ASL) is a perfusion MRI technique with tremendous applications in the study of biological markers and prognostic factors of brain tumors and in the assessment of neural diseases; moreover, it is completely non-invasive as it uses the magnetically inverted blood of the patient as an endogenous tracer. Unfortunately this powerful method is only viable in very limited conditions due to its extreme sensitivity to artifacts originated by head motion, that are not effectively addressed by the current software solutions. This paper presents a motion correction procedure that addresses this issue and provides improved solutions to enhance ASL images of the brain in presence of severe head motion. Experimental results run on a motion-affected pCASL dataset show the concept and demonstrate the superiority of our proposed procedure compared to standard 3D registration.
引用
收藏
页码:410 / 413
页数:4
相关论文
共 50 条
  • [21] EXPERIMENTAL CHARACTERIZATION OF MOTION ARTIFACT IN NMR IMAGES
    NELSON, AD
    ALFIDI, RJ
    KOPIWODA, S
    MIRALDI, F
    CLAMPITT, M
    MAGNETIC RESONANCE IN MEDICINE, 1984, 1 (02) : 285 - 286
  • [22] Ring artifact correction for industrial CT images
    School of Mechanical Engineering and Automation, Beijing University of Aeronautics and Astronautics, Beijing 100083, China
    Beijing Hangkong Hangtian Daxue Xuebao, 2007, 11 (1378-1382):
  • [23] Correction of motion artifact in CL based on MAFusNet
    Jia, Tong
    Shi, Liu
    Wei, Cunfeng
    Shi, Rongjian
    Liu, Baodong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (02) : 393 - 407
  • [24] AUTOMATED ARTIFACT DETECTION PROCEDURE FOR VAGINAL PHOTOPLETHYSMOGRAPH DATA
    Pulverman, C. S.
    Meston, C. M.
    Hixon, J. G.
    JOURNAL OF SEXUAL MEDICINE, 2015, 12 : 281 - 281
  • [25] Automated Artifact-Detection Procedure for Vaginal Photoplethysmography
    Pulverman, Carey S.
    Meston, Cindy M.
    Hixon, J. Gregory
    JOURNAL OF SEX & MARITAL THERAPY, 2018, 44 (06) : 566 - 590
  • [26] Ring artifact correction for industrial CT images
    Zhang, QH
    Lu, HN
    Yang, M
    Wang, LM
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 6, 2005, : 596 - 599
  • [27] Evaluating the Efficacy of an Automated Procedure for EEG Artifact Removal
    Tran, Yvonne
    Thuraisingham, Ranjit A.
    Craig, Ashley
    Nguyen, Hung
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 376 - +
  • [28] A Motion Artifact Correction Procedure for fNIRS Signals Based on Wavelet Transform and Infrared Thermography Video Tracking
    Perpetuini, David
    Cardone, Daniela
    Filippini, Chiara
    Chiarelli, Antonio Maria
    Merla, Arcangelo
    SENSORS, 2021, 21 (15)
  • [29] Motion correction facilitates the automation of cardiac ASL perfusion imaging
    Ahsan Javed
    Terrence R Jao
    Krishna S Nayak
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [30] Speckle noise reduction and motion artifact correction based on modified statistical parameters estimation in OCT images
    Rajabi, H.
    Zirak, A.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (03):