摘要
The influences of residual stress on the piezoelectric ultrasonic sensors having composite membrane structure included PZT (Pb(Zr0.52Ti0.48)O-3) thin film are presented. Due to the different thermal and elastic characteristics of each constitutive layer, a subsequent residual stress and deflection is usually generated on the composite membrane. We discuss the influences of residual stress on the Si-based integrated sensor device in the two point of view; the mechanical behaviors and piezoelectric thin film properties. The composite layer structure and fabrication process especially related to thermal process have significant effects on the stress state of the composite membrane. The relationships among the stress states, deflections of composite membrane and sensitivities of sensor devices are considered.
引用
收藏
页码:1428 / +
页数:2
相关论文
共 50 条
  • [21] INSTRUMENT FOR CONTINUOUS MEASUREMENT OF PLATE DEFLECTION IN RESIDUAL STRESS DETERMINATIONS
    PETROSOV, VI
    PETRYAEV, AI
    INDUSTRIAL LABORATORY, 1969, 35 (03): : 426 - &
  • [22] A comparison of neutron and ultrasonic determinations of residual stress
    Gnäupel-Herold, T
    Prask, HJ
    Clark, AV
    Hehman, CS
    Nguyen, TN
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (04) : 436 - 444
  • [23] RESIDUAL-STRESS MAPPING BY ULTRASONIC TOMOGRAPHY
    HILDEBRAND, BP
    HARRINGTON, TP
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1979, 26 (02): : 159 - 159
  • [24] A POSSIBLE ULTRASONIC RESIDUAL-STRESS STANDARD
    BLESSING, GV
    HSU, NH
    PROCTOR, TM
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (03): : 184 - 185
  • [25] ULTRASONIC MEASUREMENTS OF RESIDUAL-STRESS IN RAILS
    DEPUTAT, J
    BROKOWSKI, A
    MATERIALS EVALUATION, 1985, 43 (10) : 1342 - 1342
  • [26] ULTRASONIC TECHNIQUE FOR MEASUREMENT OF RESIDUAL-STRESS
    NORONHA, PJ
    WERT, JJ
    JOURNAL OF TESTING AND EVALUATION, 1975, 3 (02) : 147 - 152
  • [27] RESIDUAL STRESS MEASUREMENT IN AN ULTRASONIC PEENED SPECIMEN
    Ficquet, Xavier
    Hedmar, Malcolm
    Kingston, Ed J.
    33RD INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2014, VOL 5, 2014,
  • [28] ULTRASONIC DYNAMIC VECTOR STRESS SENSOR
    HEYMAN, JS
    FROGGATT, M
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 93 (06): : 3522 - 3522
  • [29] Vibration of sensor diaphragm with residual stress coupled with liquids: effect of the residual stress
    Wu, Huayong
    Zhou, Shenjie
    SENSOR REVIEW, 2014, 34 (01) : 110 - 116
  • [30] A New Experimental Methodology Using Point Deflection to Quantify Residual Stress of Thin Polymer Membrane Materials in MEMS Devices
    Soulimane, Sofiane
    Pouydebasque, Arnaud
    Bolis, Sebastien
    Jacquet, Fabrice
    Bridoux, Claudine
    Dupont, Florian
    Poulain, Christophe
    Moreau, Stephane
    Fanget, Stephane
    2013 8TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (IEEE NEMS 2013), 2013, : 486 - 489