Dual-wavelength multifrequency photothermal wave imaging combined with optical coherence tomography for macrophage and lipid detection in atherosclerotic plaques using gold nanoparticles

被引:9
|
作者
Wang, Tianyi [1 ]
Mancuso, J. Jacob [3 ]
Sapozhnikova, Veronika [3 ]
Dwelle, Jordan [1 ]
Ma, Li L. [2 ]
Willsey, Brian [2 ]
Kazmi, S. M. Shams [1 ]
Qiu, Jinze [1 ]
Li, Xiankai [3 ]
Asmis, Reto [3 ]
Johnston, Keith P. [2 ]
Feldman, Marc D. [3 ,4 ]
Milner, Thomas E. [1 ]
机构
[1] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[2] Univ Texas Austin, Dept Chem Engn, Austin, TX 78712 USA
[3] Univ Texas Hlth Sci Ctr San Antonio, Div Cardiol, San Antonio, TX 78229 USA
[4] S Texas Vet Hlth Care Syst, San Antonio, TX 78229 USA
关键词
atherosclerosis; macrophage; lipid; nanorose; photothermal wave imaging; optical coherence tomography; two-photon luminescence microscopy; CENTRAL-NERVOUS-SYSTEM; IRON-OXIDE; IN-VITRO; EXPRESSION; CELLS; INFLAMMATION; RUPTURE; LESIONS; PHARMACOKINETICS; MICROSCOPY;
D O I
10.1117/1.JBO.17.3.036009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The objective of this study was to assess the ability of combined photothermal wave (PTW) imaging and optical coherence tomography (OCT) to detect, and further characterize the distribution of macrophages (having taken up plasmonic gold nanorose as a contrast agent) and lipid deposits in atherosclerotic plaques. Aortas with atherosclerotic plaques were harvested from nine male New Zealand white rabbits divided into nanorose- and saline-injected groups and were imaged by dual-wavelength (800 and 1210 nm) multifrequency (0.1, 1 and 4 Hz) PTW imaging in combination with OCT. Amplitude PTW images suggest that lateral and depth distribution of nanorose-loaded macrophages (confirmed by two-photon luminescence microscopy and RAM-11 macrophage stain) and lipid deposits can be identified at selected modulation frequencies. Radiometric temperature increase and modulation amplitude of superficial nanoroses in response to 4 Hz laser irradiation (800 nm) were significantly higher than native plaque (P < 0.001). Amplitude PTW images (4 Hz) were merged into a coregistered OCT image, suggesting that superficial nanorose-loaded macrophages are distributed at shoulders on the upstream side of atherosclerotic plaques (P < 0.001) at edges of lipid deposits. Results suggest that combined PTW-OCT imaging can simultaneously reveal plaque structure and composition, permitting characterization of nanorose-loaded macrophages and lipid deposits in atherosclerotic plaques. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.3.036009]
引用
收藏
页数:10
相关论文
共 28 条
  • [1] Nanorose and Lipid Detection in Atherosclerotic Plaque Using Dual-wavelength Photothermal Wave Imaging
    Wang, Tianyi
    Qiu, Jinze
    Ma, Li Leo
    Li, Xiankai
    Sun, Jingjing
    Ryoo, Seungyup
    Johnston, Keith P.
    Feldman, Marc D.
    Milner, Thomas E.
    OPTICAL INTERACTIONS WITH TISSUES AND CELLS XXI, 2010, 7562
  • [2] Dual-wavelength photothermal optical coherence tomography for imaging microvasculature blood oxygen saturation
    Yin, Biwei
    Kuranov, Roman V.
    McElroy, Austin B.
    Kazmi, Shams
    Dunn, Andrew K.
    Duong, Timothy Q.
    Milner, Thomas E.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [3] Corneal hydration imaging using dual-wavelength optical coherence tomography
    Jeon, SW
    Shure, MA
    Rollins, AM
    Huang, D
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 113 - 118
  • [4] Dual-wavelength photothermal optical coherence tomography for blood oxygen saturation measurement
    Yin, Biwei
    Kuranov, Roman V.
    McElroy, Austin B.
    Milner, Thomas E.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVII, 2013, 8571
  • [5] Optimization of dual-wavelength intravascular photoacoustic imaging of atherosclerotic plaques using Monte Carlo optical modeling
    Dana, Nicholas
    Sowers, Timothy
    Karpiouk, Andrei
    Vanderlaan, Donald
    Emelianov, Stanislav
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (10)
  • [6] Photothermal detection of gold nanoparticles using phase-sensitive optical coherence tomography
    Adler, Desmond C.
    Huang, Shu-Wei
    Huber, Robert
    Fujimoto, James G.
    OPTICS EXPRESS, 2008, 16 (07): : 4376 - 4393
  • [7] Non-invasive imaging of biological tissue with dual-wavelength optical coherence tomography
    Pan, YT
    Farkas, DL
    OPTICAL INVESTIGATIONS OF CELLS IN VITRO AND IN VIVO, PROCEEDINGS OF, 1998, 3260 : 141 - 149
  • [8] DETECTION OF LIPID IN CORONARY ARTERIES USING PHOTOTHERMAL OPTICAL COHERENCE TOMOGRAPHY
    Katta, Nitesh
    Cabe, Andrew
    Hoyt, Taylor
    McElroy, Austin B.
    Feldman, Marc
    Milner, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1421 - 1421
  • [9] Intravascular optical coherence tomography method for automated detection of macrophage infiltration within atherosclerotic coronary plaques
    Rico-Jimenez, Jose J.
    Campos-Delgado, Daniel U.
    Buja, L. Maximillan
    Vela, Deborah
    Jo, Javier A.
    ATHEROSCLEROSIS, 2019, 290 : 94 - 102
  • [10] Detection of atherosclerotic plaques with HDL-like porphyrin nanoparticles using an intravascular dual-modality optical coherence tomography and fluorescence system
    Chen, Rouyan
    Sandeman, Lauren
    Nankivell, Victoria
    Tan, Joanne T. M.
    Rashidi, Mohammad
    Psaltis, Peter J.
    Zheng, Gang
    Bursill, Christina
    Mclaughlin, Robert A.
    Li, Jiawen
    SCIENTIFIC REPORTS, 2024, 14 (01):