Dual-wavelength photothermal optical coherence tomography for blood oxygen saturation measurement

被引:1
|
作者
Yin, Biwei [1 ]
Kuranov, Roman V. [1 ]
McElroy, Austin B. [1 ]
Milner, Thomas E. [1 ]
机构
[1] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
关键词
DWP-OCT; phase-sensitive; microvasculature; hemoglobin oxygen saturation; phantom microvessel; OCT;
D O I
10.1117/12.2006945
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report design and demonstration of a dual wavelength photothermal (DWP) optical coherence tomography (OCT) system for imaging of a phantom microvessel and measurement of hemoglobin oxygen saturation (SO2) level. The DWP-OCT system contains a swept-source (SS) two-beam phase-sensitive (PhS) OCT system (1060 nm) and two intensity modulated photothermal excitation lasers (770 nm and 800 nm). The PhS-OCT probe beam (1060 nm) and photothermal excitation beams are combined into one single-mode optical fiber. A galvanometer based two-dimensional achromatic scanning system is designed to provide 14 mu m lateral resolution for the PhS-OCT probe beam (1060 nm) and 13 mu m lateral resolution for photothermal excitation beams. DWP-OCT system's sensitivity is 102 dB, axial resolution is 13 mu m in tissue and uses a real-time digital dispersion compensation algorithm. Noise floor for optical pathlength measurements is 300 pm in the signal frequency range (380-400 Hz) of photothermal modulation frequencies. Blood SO2 level is calculated from measured optical pathlength (op) signal in a 300 mu m diameter microvessel phantom introduced by the two photothermal excitation beams. En-face and B-scan images of a phantom microvessel are recorded, and six blood samples' SO2 levels are measured using DWP-OCT and compared with values provided by a commercial blood oximeter. A mathematical model indicates thermal diffusion introduces a systematic artifact that over-estimates SO2 values and is consistent with measured data
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Dual-wavelength photothermal optical coherence tomography for imaging microvasculature blood oxygen saturation
    Yin, Biwei
    Kuranov, Roman V.
    McElroy, Austin B.
    Kazmi, Shams
    Dunn, Andrew K.
    Duong, Timothy Q.
    Milner, Thomas E.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [2] Depth-resolved blood oxygen saturation measurement by dual-wavelength photothermal (DWP) optical coherence tomography
    Kuranov, Roman V.
    Qiu, Jinze
    McElroy, Austin B.
    Estrada, Arnold
    Salvaggio, Anthony
    Kiel, Jeffrey
    Dunn, Andrew K.
    Duong, Timothy Q.
    Milner, Thomas E.
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (03): : 491 - 504
  • [3] Dual-wavelength imaging of blood oxygen saturation in retinal vessels
    Beach, JM
    Srinivas, SR
    Tiedeman, JS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3585 - 3585
  • [4] Corneal hydration imaging using dual-wavelength optical coherence tomography
    Jeon, SW
    Shure, MA
    Rollins, AM
    Huang, D
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 113 - 118
  • [5] Feasibility and Safety of a Coaxial Dual-Wavelength Optical Coherence Tomography Apparatus
    Cedro, Luca
    Hasler, Pascal W.
    Meier, Christoph
    Povazay, Boris
    Burri, Christian
    Mooser, Matthias
    Kaiser, Pascal
    Rothenbuehler, Simon P.
    Muller, Philipp L.
    Zarranz-Ventura, Javier
    Egan, Catherine
    Tufail, Adnan
    Scholl, Hendrik P. N.
    Maloca, Peter M.
    OPHTHALMIC RESEARCH, 2021, 64 (01) : 55 - 61
  • [6] In vivo depth-resolved oxygen saturation by dual-wavelength photothermal (DWP) OCT
    Kuranov, Roman V.
    Kazmi, Shams
    McElroy, Austin B.
    Kiel, Jeffrey W.
    Dunn, Andrew K.
    Milner, Thomas E.
    Duong, Timothy Q.
    OPTICS EXPRESS, 2011, 19 (24): : 23831 - 23844
  • [7] Numerical analysis on oxygen saturation measurement by dual-wavelength optical low-coherence interferometry - art. no. 65342S
    Wang, Ling
    Ding, Zhihua
    Huang, Lina
    Geiser, Martial
    Fifth International Conference on Photonics and Imaging in Biology and Medicine, Pts 1 and 2, 2007, 6534 : S5342 - S5342
  • [8] Extended measuring depth dual-wavelength Fourier domain optical coherence tomography
    Al-Mohamedi, Haroun
    Kelly-Perez, Ismael
    Oltrup, Theo
    Cayless, Alan
    Bende, Thomas
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2021, 66 (06): : 557 - 562
  • [9] In vivo full range dual-wavelength Fourier domain optical coherence tomography
    Al-Mohamedi, Haroun
    Prinz, Andreas
    Oltrup, Theo
    Leitritz, Martin
    Bende, Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [10] Quantitative evaluation of the impact of variation of optical parameters on the estimation of blood hematocrit and oxygen saturation for dual-wavelength photoacoustics
    Paul, Subhadip
    Patel, Hari shankar
    Saha, Ratan k.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2024, 41 (06) : 1128 - 1139