Dual-wavelength photothermal optical coherence tomography for blood oxygen saturation measurement

被引:1
|
作者
Yin, Biwei [1 ]
Kuranov, Roman V. [1 ]
McElroy, Austin B. [1 ]
Milner, Thomas E. [1 ]
机构
[1] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
关键词
DWP-OCT; phase-sensitive; microvasculature; hemoglobin oxygen saturation; phantom microvessel; OCT;
D O I
10.1117/12.2006945
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report design and demonstration of a dual wavelength photothermal (DWP) optical coherence tomography (OCT) system for imaging of a phantom microvessel and measurement of hemoglobin oxygen saturation (SO2) level. The DWP-OCT system contains a swept-source (SS) two-beam phase-sensitive (PhS) OCT system (1060 nm) and two intensity modulated photothermal excitation lasers (770 nm and 800 nm). The PhS-OCT probe beam (1060 nm) and photothermal excitation beams are combined into one single-mode optical fiber. A galvanometer based two-dimensional achromatic scanning system is designed to provide 14 mu m lateral resolution for the PhS-OCT probe beam (1060 nm) and 13 mu m lateral resolution for photothermal excitation beams. DWP-OCT system's sensitivity is 102 dB, axial resolution is 13 mu m in tissue and uses a real-time digital dispersion compensation algorithm. Noise floor for optical pathlength measurements is 300 pm in the signal frequency range (380-400 Hz) of photothermal modulation frequencies. Blood SO2 level is calculated from measured optical pathlength (op) signal in a 300 mu m diameter microvessel phantom introduced by the two photothermal excitation beams. En-face and B-scan images of a phantom microvessel are recorded, and six blood samples' SO2 levels are measured using DWP-OCT and compared with values provided by a commercial blood oximeter. A mathematical model indicates thermal diffusion introduces a systematic artifact that over-estimates SO2 values and is consistent with measured data
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Measurement of the hemoglobin oxygen saturation level with spectroscopic spectral-domain optical coherence tomography
    Lu, Chih-Wei
    Lee, Cheng-Kuang
    Tsai, Meng-Tsan
    Wang, Yih-Ming
    Yang, C. C.
    OPTICS LETTERS, 2008, 33 (05) : 416 - 418
  • [22] Polarisation sensitive dual wavelength spectroscopic optical coherence tomography
    Royset, A
    Storen, T
    Lokberg, OJ
    Lindmo, T
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES, 2003, 5140 : 87 - 94
  • [23] Dual-wavelength retinal images denoising algorithm for improving the accuracy of oxygen saturation calculation
    Xian, Yong-Li
    Dai, Yun
    Gao, Chun-Ming
    Du, Rui
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (01)
  • [24] Dual-Wavelength Diffuse Optical Tomographic System for Direct Concentration Measurement
    Das, Tapan
    Dutta, Pranab K.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (09) : 7043 - 7050
  • [25] Blood oxygen saturation measurement in human retina by using 1060 nm Fourier Domain Optical Coherence Tomography (FD-OCT)
    Reddikumar, Maddipatla
    Bose, Kingshuk
    Poddar, Raju
    2013 Workshop on Recent Advances in Photonics (WRAP), 2013,
  • [26] Dual-wavelength Digital Holography Microscope for BGA Measurement Using Partial Coherence Sources
    Cho, Hyungjun
    Kim, Doocheol
    Yu, Younghun
    Jung, Wonki
    Shin, Sanghoon
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2011, 15 (04) : 352 - 356
  • [27] QUANTIFICATION OF THE HEMATOPORPHYRIN DERIVATIVE BY FLUORESCENCE MEASUREMENT USING DUAL-WAVELENGTH EXCITATION AND DUAL-WAVELENGTH DETECTION
    SINAASAPPEL, M
    STERENBORG, HJCM
    APPLIED OPTICS, 1993, 32 (04): : 541 - 548
  • [28] Dual-wavelength Laser System and Cavity Stabilization Scheme of Dual-wavelength Active Optical Clock
    Pan, Duo
    Shi, Tiantian
    Chen, Jingbiao
    2018 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (IFCS), 2018, : 309 - 311
  • [29] Dual angle Scan Protocol with Doppler Optical Coherence Tomography for Retinal Blood Flow Measurement
    Tan, Ou
    Wang, Yimin
    Huang, David
    MEDICAL IMAGING 2011: COMPUTER-AIDED DIAGNOSIS, 2011, 7963
  • [30] Absolute Retinal Blood Flow Measurement With a Dual-Beam Doppler Optical Coherence Tomography
    Dai, Cuixia
    Liu, Xiaojing
    Zhang, Hao F.
    Puliafito, Carmen A.
    Jiao, Shuliang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (13) : 7998 - 8003