摘要
BACKGROUND. Manual surveillance for central line-associated bloodstream infections (CLABSIs) by infection prevention practitioners is time-consuming and often limited to intensive care units (ICUs). An automated surveillance system using existing databases with patient-level variables and microbiology data was investigated. METHODS. Patients with a positive blood culture in 4 non-ICU wards at Barnes-Jewish Hospital between July 1, 2005, and December 31, 2006, were evaluated. CLABSI determination for these patients was made via 2 sources; a manual chart review and an automated review from electronically available data. Agreement between these 2 sources was used to develop the best-fit electronic algorithm that used a set of rules to identify a CLABSI. Sensitivity, specificity, predictive values, and Pearson's correlation were calculated for the various rule sets, using manual chart review as the reference standard. RESULTS. During the study period, 391 positive blood cultures from 331 patients were evaluated. Eighty-five (22%) of these were confirmed to be CLABSI by manual chart review. The best-fit model included presence of a catheter, blood culture positive for known pathogen or blood culture with a common skin contaminant confirmed by a second positive culture and the presence of fever, and no positive cultures with the same organism from another sterile site. The best-performing rule set had an overall sensitivity of 95.2%, specificity of 97.5%, positive predictive value of 90%, and negative predictive value of 99.2% compared with intensive manual surveillance. CONCLUSIONS. Although CLABSIs were slightly overpredicted by electronic surveillance compared with manual chart review, the method offers the possibility of performing acceptably good surveillance in areas where resources do not allow for traditional manual surveillance. Infect Control Hosp Epidemiol 2011; 32(11): 1086-1090
引用
下载
收藏
页码:1086 / 1090
页数:5
相关论文
共 50 条
  • [31] Costs of healthcare-associated infections in an Intensive Care Unit
    Leal, Michelle Araujo
    de Freitas-Vilela, Ana Amelia
    REVISTA BRASILEIRA DE ENFERMAGEM, 2021, 74 (01)
  • [32] Healthcare-associated infections in the pediatric intensive care unit
    Guzman-Cottrill, Judith A.
    Kirby, Aileen
    JOURNAL OF PEDIATRIC INTENSIVE CARE, 2014, 3 (04) : 281 - 289
  • [33] Use of Six Sigma Strategies to Pull the Line on Central Line-Associated Bloodstream Infections in a Neurotrauma Intensive Care Unit
    Loftus, Kelli
    Tilley, Terry
    Hoffman, Jason
    Bradburn, Eric
    Harvey, Ellen
    JOURNAL OF TRAUMA NURSING, 2015, 22 (02) : 78 - 86
  • [34] Healthcare-associated infections in a neonatal intensive care unit
    Sadowska-Krawczenko, Iwona
    Jankowska, Aldona
    Kurylak, Andrzej
    ARCHIVES OF MEDICAL SCIENCE, 2012, 8 (05) : 854 - 858
  • [35] Risk factors for central line-associated bloodstream infections: Preliminary analysis of the detailed intensive care unit surveillance component study.
    Alonso-Echanove, J
    Edwards, J
    Richards, M
    Gaynes, RP
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2000, 21 (02): : 93 - 93
  • [36] Beyond the bundle - journey of a tertiary care medical intensive care unit to zero central line-associated bloodstream infections
    Exline, Matthew C.
    Ali, Naeem A.
    Zikri, Nancy
    Mangino, Julie E.
    Torrence, Kelly
    Vermillion, Brenda
    St Clair, Jamie
    Lustberg, Mark E.
    Pancholi, Preeti
    Sopirala, Madhuri M.
    CRITICAL CARE, 2013, 17 (02):
  • [37] Minimizing central line-associated bloodstream infections in a high-acuity liver transplant intensive care unit
    Russell, Tara A.
    Fritschel, Elyse
    Do, Jennifer
    Donovan, Melanie
    Keckeisen, Maureen
    Agopian, Vatche G.
    Farmer, Douglas G.
    Wang, Tisha
    Rubin, Zachary
    Busuttil, Ronald W.
    Kaldas, Fady M.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2019, 47 (03) : 305 - 312
  • [38] The Ability of Intensive Care Units to Maintain Zero Central Line-Associated Bloodstream Infections
    Lipitz-Snyderman, Allison
    Needham, Dale M.
    Colantuoni, Elizabeth
    Goeschel, Christine A.
    Marsteller, Jill A.
    Thompson, David A.
    Berenholtz, Sean M.
    Lubomski, Lisa H.
    Watson, Sam
    Pronovost, Peter J.
    ARCHIVES OF INTERNAL MEDICINE, 2011, 171 (09) : 856 - 858
  • [39] Indirect Versus Direct Standardization Methods for Reporting Healthcare-Associated Infections: An Analysis of Central Line-Associated Bloodstream Infections in Maryland
    O'Hara, Lyndsay M.
    Masnick, Max
    Leekha, Surbhi
    Jackson, Sarah S.
    Blanco, Natalia
    Harris, Anthony D.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2017, 38 (08): : 989 - 992
  • [40] Effectiveness of a central line bundle campaign on line-associated infections in the intensive care unit
    Galpern, David
    Guerrero, Alejandro
    Tu, Ann
    Fahoum, Bashar
    Wise, Leslie
    SURGERY, 2008, 144 (04) : 492 - 495