Performance of the Liquid Xenon Scintillation Detector for the MEG Experiment

被引:0
|
作者
Ootani, W. [1 ]
机构
[1] Univ Tokyo, Int Ctr Elementary Particle Phys, Tokyo, Japan
关键词
D O I
10.1109/NSSMIC.2006.356001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A large-volume liquid xenon (LXe) scintillation detector has been developed for the MEG experiment, which will seek evidence for the lepton flavor violating process, mu -> e gamma with a branching ratio sensitivity smaller than 10(-13). A prototype detector with 100 L LXe was constructed to demonstrate that the performance of the proposed full-scale detector fulfills the requirements for the MEG experiment. New photomultipliers with a higher quantum efficiency and better performance under high rate environment were recently developed and employed in the prototype detector. The performance of the detector was measured with high-energy monochromatic photons from pi (0) decays produced in the charge exchange (CEX) process. We obtained an energy resolution of 1.2 +/- 0.1 % in sigma on the right side of the peak for the 55 MeV photons. The timing resolution was also measured to be 65 psec in sigma
引用
收藏
页码:940 / 942
页数:3
相关论文
共 50 条
  • [41] A measurement of the scintillation decay time constant in liquid xenon with the XMASS-I detector
    Ichimura, K.
    16TH INTERNATIONAL CONFERENCE ON TOPICS IN ASTROPARTICLE AND UNDERGROUND PHYSICS (TAUP 2019), 2020, 1468
  • [42] The detector for the new μ → eγ experiment MEG
    Mori, T
    ICHEP 2002, PROCEEDINGS, 2003, : 942 - 944
  • [43] LIQUID XENON SCINTILLATION SPECTROMETER.
    Barabanov, I.R.
    Gavrin, V.N.
    Pshukov, A.M.
    Nuclear instruments and methods in physics research, 1987, A254 (02): : 355 - 360
  • [44] A radioactive point-source lattice for calibrating and monitoring the liquid xenon calorimeter of the MEG experiment
    Baldini, A.
    Bemporad, C.
    Cei, F.
    Dussoni, S.
    Gatti, F.
    Grassi, M.
    Haruyama, T.
    Hisamatsu, Y.
    Iwamoto, T.
    Mihara, S.
    Mori, T.
    Nicolo, D.
    Nishiguchi, H.
    Ootani, W.
    Papa, A.
    Pazzi, R.
    Sawada, R.
    Sergiampietri, F.
    Signorelli, G.
    Valle, R.
    Yamada, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (02): : 589 - 598
  • [45] Performance of prototype liquid xenon scintillation detector system for time-of-flight type positron emission tomography with improved photomultipliers
    Nishikido, F
    Doke, T
    Kikuchi, J
    Mori, T
    Murayama, H
    Ooshita, T
    Takahashi, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (7A): : 5193 - 5198
  • [46] Position Reconstruction in a Dual Phase Xenon Scintillation Detector
    Solovov, V. N.
    Belov, V. A.
    Akimov, D. Yu
    Araujo, H. M.
    Barnes, E. J.
    Burenkov, A. A.
    Chepel, V.
    Currie, A.
    DeViveiros, L.
    Edwards, B.
    Ghag, C.
    Hollingsworth, A.
    Horn, M.
    Kalmus, G. E.
    Kobyakin, A. S.
    Kovalenko, A. G.
    Lebedenko, V. N.
    Lindote, A.
    Lopes, M. I.
    Luescher, R.
    Majewski, P.
    Murphy, A. S. J.
    Neves, F.
    Paling, S. M.
    Pinto da Cunha, J.
    Preece, R.
    Quenby, J. J.
    Reichhart, L.
    Scovell, P. R.
    Silva, C.
    Smith, N. J. T.
    Smith, P. F.
    Stekhanov, V. N.
    Sumner, T. J.
    Thorne, C.
    Walker, R. J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (06) : 3286 - 3293
  • [47] Position Reconstruction in a Dual Phase Xenon Scintillation Detector
    Solovov, V. N.
    Belov, V. A.
    Akimov, D. Yu
    Araujo, H. M.
    Barnes, E. J.
    Burenkov, A. A.
    Chepel, V.
    Currie, A.
    DeViveiros, L.
    Edwards, B.
    Ghag, C.
    Hollingsworth, A.
    Horn, M.
    Kalmus, G. E.
    Kobyakin, A. S.
    Kovalenko, A. G.
    Lebedenko, V. N.
    Lindote, A.
    Lopes, M. I.
    Luescher, R.
    Majewski, P.
    Murphy, A. St J.
    Neves, F.
    Paling, S. M.
    Pinto da Cunha, J.
    Preece, R.
    Quenby, J. J.
    Reichhart, L.
    Scovell, P. R.
    Silva, C.
    Smith, N. J. T.
    Smith, P. F.
    Stekhanov, V. N.
    Sumner, T. J.
    Thorne, C.
    Walker, R. J.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1226 - 1233
  • [48] LIQUID XENON AS A DETECTOR MEDIUM
    INCICCHITTI, A
    BELLI, P
    SCAFI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 289 (1-2): : 236 - 242
  • [49] Background identification system in MEG II experiment based on high-rate scintillation detector with SiPM readout
    Iwai, R.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [50] Performance of a large area avalanche photodiode in a liquid xenon ionization and scintillation chamber
    Ni, K
    Aprile, E
    Day, D
    Giboni, KL
    Lopes, JAM
    Majewski, P
    Yamashita, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 551 (2-3): : 356 - 363