Performance of the Liquid Xenon Scintillation Detector for the MEG Experiment

被引:0
|
作者
Ootani, W. [1 ]
机构
[1] Univ Tokyo, Int Ctr Elementary Particle Phys, Tokyo, Japan
关键词
D O I
10.1109/NSSMIC.2006.356001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A large-volume liquid xenon (LXe) scintillation detector has been developed for the MEG experiment, which will seek evidence for the lepton flavor violating process, mu -> e gamma with a branching ratio sensitivity smaller than 10(-13). A prototype detector with 100 L LXe was constructed to demonstrate that the performance of the proposed full-scale detector fulfills the requirements for the MEG experiment. New photomultipliers with a higher quantum efficiency and better performance under high rate environment were recently developed and employed in the prototype detector. The performance of the detector was measured with high-energy monochromatic photons from pi (0) decays produced in the charge exchange (CEX) process. We obtained an energy resolution of 1.2 +/- 0.1 % in sigma on the right side of the peak for the 55 MeV photons. The timing resolution was also measured to be 65 psec in sigma
引用
收藏
页码:940 / 942
页数:3
相关论文
共 50 条
  • [1] Liquid Xenon scintillation detector for the MEG experiment
    Iwamoto, T
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 130 - 132
  • [2] Performance of the liquid xenon detector for the MEG experiment
    Nishimura, Yasuhiro
    Natori, Hiroaki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 376 - 380
  • [3] Liquid xenon detector for the MEG experiment
    Iwamoto, Toshiyuki
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 172 : 224 - 226
  • [4] Upgrade of the liquid xenon γ-ray detector in the MEG experiment
    Kaneko, Daisuke
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 457 - 462
  • [5] Performance of UV-Sensitive MPPC for Liquid Xenon Detector in MEG Experiment
    Kaneko, Daisuke
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [6] MEG liquid xenon detector
    Mihara, Satoshi
    1ST INTERNATIONAL WORKSHOP TOWARDS THE GIANT LIQUID ARGON CHARGE IMAGING EXPERIMENT, 2011, 308
  • [7] Performance of liquid xenon gamma ray detector for MEG
    Sawada, Ryu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 258 - 260
  • [8] Study on degradation of VUV-sensitivity of MPPC for liquid xenon scintillation detector by radiation damage in MEG II experiment
    Ieki, K.
    Iwamoto, T.
    Kobayashi, S.
    Mori, Toshinori
    Ogawa, S.
    Onda, R.
    Ootani, W.
    Shimada, K.
    Toyoda, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1053
  • [9] Performance of a liquid xenon calorimeter cryogenic system for the MEG experiment
    Haruyama, T.
    Kasami, K.
    Hisamitsu, Y.
    Iwamoto, T.
    Mihara, S.
    Mori, T.
    Nishiguchi, H.
    Otani, W.
    Sawada, R.
    Uchiyama, Y.
    Nishitani, T.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 1193 - +
  • [10] The liquid xenon calorimeter of the MEG experiment
    Cei, Fabrizio
    IFAE 2006: ITALIAN MEETING ON HIGH ENERGY PHYSICS, 2007, : 339 - +