Comparison of air displacement plethysmography with dual-energy X-ray absorptiometry and 3 field methods for estimating body composition in middle-aged men

被引:111
|
作者
Sardinha, LB
Lohman, TG
Teixeira, PJ
Guedes, DP
Going, SB
机构
[1] Univ Arizona, Dept Physiol, Body Composit Res Lab, Tucson, AZ 85721 USA
[2] Univ Tecn Lisboa, Fac Human Movement, Exercise & Hlth Lab, P-1100 Lisbon, Portugal
来源
关键词
bioelectrical impedance analysis; BIA; bioelectrical impedance spectroscopy; dual-energy X-ray absorptiometry; DXA; air displacement plethysmography; percentage body fat; predictive accuracy; reliability; Portugal; men;
D O I
10.1093/ajcn/68.4.786
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
This study was designed to compare air displacement plethysmography with dual-energy X-ray absorptiometry (DXA) and 3 other field methods for estimation of body composition. Subjects were 62 healthy, white men aged 37.6 +/- 2.9 y (weight: 81.8 +/- 11.3 kg; height: 171.5 +/- 4.9 cm). Body composition was also assessed by using body mass index, single-frequency bioelectrical impedance analysis, multifrequency bioelectrical impedance spectroscopy, and the skinfold-thickness equations of Jackson and Pollock and Durnin and Womersley. Percentage body fat (%BF) with the plethysmograph was 23.4 +/- 7.0 and with DXA was 26.0 +/- 7.4. The 2.6% mean difference was significant (P < 0.05). Total error was 3.7%BF As assessed by multiple regression analysis, %BF with the plethysmograph, age, weight, and height yielded a DXA-adjusted R-2 value of 89.5% fat and an SEE of 2.4% fat. All other models had higher SEEs and lower adjusted R-2 values: 4.3% and 66.5% for body mass index, 3.3% and 79.8% for bioelectrical impedance analysis, 3.6% and 76.2% for bioelectrical impedance spectroscopy, 3.7% and 74.55% for the equations of Jackson and Pollock, and 3.9% and 71.6% for the equations of Durnin and Womersley, respectively. The plethysmograph also predicted fat mass and fat-free mass more accurately than all other models, with a lower SEE and higher adjusted R-2 value. In conclusion, although %BF was systematically underestimated, body composition was closely estimated with air displacement plethysmography in middle-aged men.
引用
收藏
页码:786 / 793
页数:8
相关论文
共 50 条
  • [41] Bioelectrical impedance vs air displacement plethysmography and dual-energy X-ray absorptiometry to determine body composition in patients with end-stage renal disease
    Flakoll, PJ
    Kent, P
    Neyra, R
    Levenhagen, D
    Chen, KY
    Ikizler, TA
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2004, 28 (01) : 13 - 21
  • [42] ASSESSMENT OF BODY-COMPOSITION WITH USE OF DUAL-ENERGY X-RAY ABSORPTIOMETRY - EVALUATION AND COMPARISON WITH OTHER METHODS
    JENSEN, MD
    KANALEY, JA
    ROUST, LR
    OBRIEN, PC
    BRAUN, JS
    DUNN, WL
    WAHNER, HW
    MAYO CLINIC PROCEEDINGS, 1993, 68 (09) : 867 - 873
  • [43] The influence of magnetic resonance imaging findings of degenerative disease on dual-energy X-ray absorptiometry measurements in middle-aged men
    Donescu, O. S.
    Battie, M. C.
    Videman, T.
    ACTA RADIOLOGICA, 2007, 48 (02) : 193 - 199
  • [44] Comparing Dual Energy X-ray Absorptiometry and Air-Displacement-Plethysmography Body Composition Evaluations in Male Collegiate Hockey Players
    Insogna, Jessica A.
    Prokop, Neal W.
    Reid, Ryan E. R.
    Bonneau, Jonathan
    Delisle-Houde, Patrick
    Buchan, Tayler A.
    Andersen, Ross E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 389 - 390
  • [45] Estimating lean body mass by dual-energy x-ray absorptiometry -: In reply
    Heimbürger, O
    Stenvinkel, P
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 38 (01) : 221 - 221
  • [46] Agreement Between Different Body Composition Methods And Dual-energy X-ray Absorptiometry In Adults
    Ferreira, Tathiany J.
    Pessanha, Carolina R.
    da Costa, Gabriel G.
    Bittencourt, Victor Z.
    Salvador, Igor C.
    Assumpcao, Ana Clara R.
    Sacom, Joao Pedro B.
    Silva, Renata R. M.
    Souza, Marcio L. R.
    Pierucci, Anna Paola T. R.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 648 - 649
  • [47] Validity and reliability of bioelectrical impedance analysis to estimate body fat percentage against air displacement plethysmography and dual-energy X-ray absorptiometry
    von Hurst, Pamela R.
    Walsh, Daniel C. I.
    Conlon, Cathryn A.
    Ingram, Michelle
    Kruger, Rozanne
    Stonehouse, Welma
    NUTRITION & DIETETICS, 2016, 73 (02) : 197 - 204
  • [48] Body composition assessment by dual-energy X-ray absorptiometry: Comparison of prone and supine measurements
    Lambrinoudaki, I
    Georgiou, E
    Douskas, G
    Tsekes, G
    Kyriakidis, M
    Proukakis, C
    METABOLISM-CLINICAL AND EXPERIMENTAL, 1998, 47 (11): : 1379 - 1382
  • [49] Comparison of Anthropometry, Bioelectrical Impedance, and Dual-energy X-ray Absorptiometry for Body Composition in Cirrhosis
    Grover, Indu
    Singh, Namrata
    Gunjan, Deepak
    Pandey, Ravindra M.
    Sati, Hem Chandra
    Saraya, Anoop
    JOURNAL OF CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2022, 12 (02) : 467 - 474
  • [50] Air Displacment Plethysmography Versus Dual Energy X-ray Absorptiometry For Body Composition Assessment In Female Athletes
    Snarr, Ronald L., Jr.
    Williford, Henry N.
    Esco, Michael R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 618 - 618