Seven-year prospective clinical study on zirconia-based single crowns and fixed dental prostheses

被引:37
|
作者
Tartaglia, Gianluca M. [1 ,2 ]
Sidoti, Ernesto [2 ]
Sforza, Chiarella [1 ]
机构
[1] Univ Milan, Lab Anat Funz Apparato Stomatognat, Dipartimento Sci Biomed Salute, Fac Med & Chirurg,FARC, I-20133 Milan, Italy
[2] SST Studio Associato Sidoti & Tartaglia, Segrate Mi, Italy
关键词
Zirconia; All ceramic; Single crown; Fixed dental prostheses; Implants; Clinical performance; HEALTHY-YOUNG ADULTS; ALL-CERAMIC CROWNS; ZRSIO4-CERAMIC CROWNS; PARTIAL DENTURES; POSTERIOR FDPS; SURVIVAL; METAL; TRIAL; COMPLICATIONS; FRAMEWORKS;
D O I
10.1007/s00784-014-1330-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives Zirconia-based prostheses are used for esthetic crown and fixed restorations, but follow-ups are still limited. The authors evaluated the 7-year clinical results of 303 zirconia core restorations, performed in a general dental private practice. Materials and methods Clinical events (fracture and loss of retention, gingivitis, tenderness, excess cement, and temporary pain) were recorded in 303 zirconia core restorations positioned in 88 patients. Kaplan-Meier survival probability estimates were computed for failures (needed the replacement or removal of the prosthesis) and complications (resolved without replacing the prosthesis). Results One hundred and fifty single crowns (130 tooth-supported, 20 implant-supported) and 153 multiple units up to 6 elements (49 tooth-supported, 104 implant-supported) were followed-up for 7 years in 88 patients (40 men, 48 women), aged 35-89 years (mean 57). During the follow-up period, there were no complications for 287 (95%) of the restorations. Sixteen restorations/abutment teeth (5 %) had some complication: extraction of abutment tooth (7, 2 %); caries (2, 1 %), porcelain veneer fracture (3, 1 %), loss of retention (4, 1 %). Nine (3 %) restorations were recorded as failures. The overall 7-year survival probability estimate for failures was 0.966 (95 % confidence limits, 0.932 and 0.983), for complications was 0.976 (95 % confidence limits 0.947 and 0.989), with a cumulative survival rate of 94.7 %. Conclusions Within the analyzed follow-up, zirconia core restorations appear a good clinical solution, with favorable functional properties. Clinical relevance All ceramic restorations can be successfully used for both single-and multiple-unit prostheses, either teeth or implants supported.
引用
收藏
页码:1137 / 1145
页数:9
相关论文
共 50 条
  • [21] A PROSPECTIVE EVALUATION OF ZIRCONIA POSTERIOR FIXED DENTAL PROSTHESES: THREE-YEAR CLINICAL RESULTS
    Pelaez, Jesus
    Cogolludo, Pablo G.
    Serrano, Benjamin
    Lozano, Jose F. L.
    Suarez, Maria J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (06): : 373 - 379
  • [22] Prospective Evaluation of Posterior Fixed Zirconia Dental Prostheses: 10-Year Clinical Results
    Rinke, Sven
    Wehle, Jens
    Schulz, Xenia
    Bruegers, Ralf
    Roediger, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (01) : 35 - 42
  • [23] Current Scientific Evidence of Clinical Performance of Veneered Zirconia Crowns and Fixed Dental Prostheses
    Roscoe M.G.
    Cavalero J.G.
    Barboza M.S.T.
    Ballester R.Y.
    Meira J.B.C.
    Current Oral Health Reports, 2020, 7 (4) : 352 - 360
  • [24] COMPLETE AND PARTIAL CONTOUR ZIRCONIA DESIGNS FOR CROWNS AND FIXED DENTAL PROSTHESES: A CLINICAL REPORT
    Marchack, Baldwin W.
    Sato, Shoko
    Marchack, Christopher B.
    White, Shane N.
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (03): : 145 - 152
  • [25] Evaluation of zirconia-based posterior single crowns supported by zirconia implants: preliminary results of a prospective multicenter study
    Spies, Benedikt Christopher
    Kohal, Ralf-Joachim
    Balmer, Marc
    Vach, Kirstin
    Jung, Ronald E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (05) : 613 - 619
  • [26] Five year clinical outcomes of metal ceramic and zirconia-based implant-supported dental prostheses: A retrospective study
    Nejatidanesh, Farahnaz
    Abbasi, Mahsa
    Savabi, Ghazal
    Bonakdarchian, Morteza
    Atash, Ramin
    Savabi, Omid
    JOURNAL OF DENTISTRY, 2020, 100
  • [27] Flexural strength of small connector designs of zirconia-based partial fixed dental prostheses
    Hamza, Tamer A.
    Attia, Mazen A.
    El-Hossary, Mohamed Mahmoud Khalil
    Mosleh, Ihab E.
    Shokry, Tamer E.
    Wee, Alvin G.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (02): : 224 - 229
  • [28] Prospective cohort clinical study assessing the 5-year survival and success of anterior maxillary zirconia-based crowns with customized zirconia copings
    Dogan, Sami
    Raigrodski, Ariel J.
    Zhang, Hai
    Mancl, Lloyd A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (02): : 226 - 232
  • [29] Implant-supported fixed cantilever prostheses in partially edentulous arches. A seven-year prospective study
    Romeo, E
    Lops, D
    Margutti, E
    Ghisolfi, M
    Chiapasco, M
    Vogel, G
    CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (03) : 303 - 311
  • [30] Clinical Evaluation of Tooth-Supported Zirconia-Based Fixed Dental Prostheses: A Retrospective Cohort Study from the AIOP Clinical Research Group
    Monaco, Carlo
    Caldari, Mauro
    Scotti, Roberto
    Agnini, Alessandro
    Barazzutti, Ferruccio
    Bianchessi, Carlo
    Biscaro, Leonello
    Billi, Mauro
    Boni, Federico
    Calesini, Gaetano
    Carboncini, Fabio
    Cortellini, Davide
    Maglione, Michele
    Manicone, Paolo Francesco
    Micarelli, Costanza
    Noe, Gaetano
    Poggio, Carlo
    Risciotti, Emanuele
    Valenti, Marco
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (03) : 236 - 238