Predictive functional control based on fuzzy model for heat-exchanger pilot plant

被引:83
|
作者
Skrjanc, I [1 ]
Matko, D [1 ]
机构
[1] Univ Ljubljana, Fac Elect & Comp Engn, Ljubljana 1000, Slovenia
关键词
fuzzy identification; predictive control; real-time control;
D O I
10.1109/91.890329
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper, a new method of predictive control is presented, Tn this approach, a well-known method of predictive functional control is combined with fuzzy model of the process. The prediction Is based on fuzzy model given in the form of Takagi-Sugeno (T-S) type. The proposed fuzzy predictive control has been evaluated by implementation on heat-exchanger plant, which exhibits a strong nonlinear behavior. It has been shown that in the case of nonlinear processes, the approach using fuzzy predictive control gives very promising results. The proposed approach is potentially interesting in the case of batch reactors, heat-exchangers, furnaces, and all the processes that are difficult to model.
引用
收藏
页码:705 / 712
页数:8
相关论文
共 50 条
  • [31] Robust Model Predictive Control of Heat Exchanger Network
    Bakosova, Monika
    Oravec, Juraj
    16TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION (PRES'13), 2013, 35 : 241 - 246
  • [32] Robust model predictive control of a plate heat exchanger
    Oravec J.
    Bakošová M.
    Vasičkaninová A.
    Mészáros A.
    2018, Italian Association of Chemical Engineering - AIDIC (70): : 25 - 30
  • [33] Robust model predictive control for heat exchanger network
    Bakosova, Monika
    Oravec, Juraj
    APPLIED THERMAL ENGINEERING, 2014, 73 (01) : 924 - 930
  • [34] ANALYTICAL MODEL OF SOLAR POND WITH HEAT-EXCHANGER
    RAO, SK
    KAUSHIKA, ND
    ENERGY CONVERSION AND MANAGEMENT, 1983, 23 (01) : 23 - 31
  • [35] Mathematical programming model for heat-exchanger network synthesis including detailed heat-exchanger designs. 1. Shell-and-tube heat-exchanger design
    Mizutani, FT
    Pessoa, FLP
    Queiroz, EM
    Hauan, S
    Grossmann, IE
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2003, 42 (17) : 4009 - 4018
  • [36] A MODEL FOR FIXED-TUBESHEET HEAT-EXCHANGER
    CASCALES, DH
    MILITELLO, C
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 1987, 109 (03): : 289 - 296
  • [37] Fault detection of an industrial heat-exchanger: A model-based approach
    University of Maribor, Faculty of Logistics, Mariborska c. 7, 3000 Celje, Slovenia
    Stroj Vest, 6 (477-484):
  • [38] Multiple modeling and fuzzy predictive control of a tubular heat exchanger system
    Islamic Azad University-Science and Research Branch, Iran
    不详
    WSEAS Trans. Syst. Control, 2008, 4 (249-258):
  • [39] Fault Detection of an Industrial Heat-Exchanger: A Model-Based Approach
    Dragan, Dejan
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2011, 57 (06): : 477 - 484
  • [40] On the application of fuzzy predictive control based on multiple models strategy to a tubular heat exchanger system
    Mazinan, A. H.
    Sadati, N.
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2010, 32 (04) : 395 - 418