Performance study of a heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system

被引:61
|
作者
Zhang, Ning [1 ]
Yin, Shao-You [2 ]
Zhang, Li-Zhi [1 ,3 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Educ Minist, Key Lab Enhanced Heat Transfer & Energy Conservat, Guangzhou 510640, Guangdong, Peoples R China
[2] Shunde Polytech, Heat Pump Engn & Technol Dev Ctr Guangdong Univ, Foshan 528333, Peoples R China
[3] South China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Guangdong, Peoples R China
关键词
Heat pump; Hollow fiber membrane; Liquid desiccant; Two-stage; System performance; COOLING SYSTEM; MASS-TRANSFER; HVAC SYSTEMS; ENERGY; REGENERATION; OPTIMIZATION; TEMPERATURE; EXCHANGERS; SIMULATION; CHILLERS;
D O I
10.1016/j.apenergy.2016.07.037
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel compression heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system is presented. The liquid desiccant droplets are prevented from crossing over into the process air by the semi-permeable membranes. The isoenthalpic processes are changed to quasi isothermal processes by the two-stage dehumidification processes. The system is set up and a model is proposed for simulation. Heat and mass capacities in the system, including the membrane modules, the condenser, the evaporator and the heat exchangers are modeled in detail. The model is also validated experimentally. Compared with a single-stage dehumidification system, the two-stage system has a lower solution concentration exiting from the dehumidifier and a lower condensing temperature. Thus, a better thermodynamic system performance is realized and the COP can be increased by about 20% under the typical hot and humid conditions in Southern China. The allocations of heat and mass transfer areas in the system are also investigated. It is found that the optimal regeneration to dehumidification area ratio is 1.33. The optimal first to second stage dehumidification area ratio is 1.4; and the optimal first to second stage regeneration area ratio is 1.286. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:727 / 737
页数:11
相关论文
共 50 条
  • [1] A heat pump driven and hollow fiber membrane-based liquid desiccant air dehumidification system: A transient performance study
    Zhang, Ning
    Zhang, Li-Zhi
    Xu, Jian-Chang
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 143 - 156
  • [2] Investigation on capacity matching in a heat pump and hollow fiber membrane-based two-stage liquid desiccant hybrid air dehumidification system
    Zhang, Ning
    Yin, Shao-You
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 : 128 - 138
  • [3] Model-based optimization for a heat pump driven and hollow fiber membrane hybrid two-stage liquid desiccant air dehumidification system
    Zhang, Ning
    Yin, Shao-You
    Li, Min
    APPLIED ENERGY, 2018, 228 : 12 - 20
  • [4] A heat pump driven and hollow fiber membrane-based liquid desiccant air dehumidification system: Modeling and experimental validation
    Zhang, Li-Zhi
    Zhang, Ning
    ENERGY, 2014, 65 : 441 - 451
  • [5] Performance Investigation of a Hollow Fiber Membrane-Based Desiccant Liquid Air Dehumidification System
    Englart, Sebastian
    Rajski, Krzysztof
    ENERGIES, 2021, 14 (11)
  • [6] Performance study of two-stage liquid desiccant dehumidification system
    Xiong, Zhen-Qin
    Dai, Yan-Jun
    Wang, Ru-Zhu
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2009, 43 (05): : 783 - 788
  • [7] Study of energy matching characteristics of solar energy driven membrane-based liquid desiccant system for air dehumidification
    Yin, Shaoyou
    Zhang, Ning
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (04): : 957 - 962
  • [8] Researches and trends in membrane-based liquid desiccant air dehumidification
    Huang, Si-Min
    Zhang, Li-Zhi
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 28 : 425 - 440
  • [9] Performance of heat pump driven internally cooled liquid desiccant dehumidification system
    Liu, Jun
    Liu, Xiaohua
    Zhang, Tao
    ENERGY CONVERSION AND MANAGEMENT, 2020, 205
  • [10] Performance Study on a Heat Pump Driven Three-stage Liquid Desiccant Deep Dehumidification Processor
    Zhang, Haiqiang
    Liu, Xiaohua
    Jiang, Yi
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 679 - 686