Study of the Rotor Screen for a 12 MW Superconducting Direct-Drive Wind Generator

被引:0
|
作者
Liu, Ying Zhen [1 ]
Qu, Rong Hai [1 ]
Zhu, Zhe [1 ]
Wang, Jin [1 ]
Fang, Hai Yang [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
关键词
eddy current losses; mechanical performance; rotor screen; short-circuit fault; shielding performance;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A rotor screen is employed in superconducting machines between field coils and armature windings, which can be made of magnetic or conductive materials. Since superconducting machines have better performances in torque density, efficiency and weight, detailed analysis of rotor screen is needed for the growing interests in superconducting wind generators. In this paper, the rotor screen of a 12 MW superconducting direct-drive wind generator with an air-cored rotor is discussed based on 2D Finite Element (FE) models, such as electromagnetic performances and mechanical performances.
引用
收藏
页码:458 / 459
页数:2
相关论文
共 50 条
  • [21] Structural integrity of a direct-drive generator for a floating wind turbine
    Sethuraman, Latha
    Venugopal, Vengatesan
    Zavvos, Aristeidis
    Mueller, Markus
    Renewable Energy, 2014, 63 : 597 - 616
  • [22] Comparison of direct-drive and geared generator concepts for wind turbines
    Polinder, Henk
    van der Pijl, Frank F. A.
    de Vilder, Gert-Jan
    Tavner, Peter J.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (03) : 725 - 733
  • [23] Design of a 10 MW Multi-Phase PM Synchronous Generator for Direct-Drive Wind Turbines
    Damiano, Alfonso
    Marongiu, Ignazio
    Monni, Andrea
    Porru, Mario
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 5266 - 5270
  • [24] Structural integrity of a direct-drive generator for a floating wind turbine
    Sethuraman, Latha
    Venugopal, Vengatesan
    Zavvos, Aristeidis
    Mueller, Markus
    RENEWABLE ENERGY, 2014, 63 : 597 - 616
  • [25] Promising direct-drive generator system for large wind turbines
    Bang, Deok-Je
    Polinder, Henk
    Shrestha, Ghanshyam
    Ferreira, Jan Abraham
    2008 PROCEEDINGS OF THE EPE WIND ENERGY CHAPTER-1ST SEMINAR, 2008, : 43 - 52
  • [26] 10 MW wind turbine direct-drive generator design with pitch or active speed stall control
    Polinder, H.
    Bang, D.
    van Rooij, R. P. J. O. M.
    McDonald, A. S.
    Mueller, M. A.
    IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, : 1390 - +
  • [27] Comparison of Superconducting Generators and Permanent Magnet Generators for 10-MW Direct-Drive Wind Turbines
    Liu, Dong
    Polinder, Henk
    Abrahamsen, Asger B.
    Wang, Xuezhou
    Ferreira, Jan A.
    2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [28] The effect of the rotor adjustment on the vibration behaviour of the drive-train system for a 5MW direct-drive wind turbine
    Ye, Kan
    Ji, Jinchen
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2018, 232 (17) : 3027 - 3044
  • [29] A 5MW direct-drive generator for floating spar-buoy wind turbine: Drive-train dynamics
    Sethuraman, Latha
    Xing, Yihan
    Venugopal, Vengatesan
    Gao, Zhen
    Mueller, Markus
    Moan, Torgeir
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (04) : 744 - 763
  • [30] Parametric AC Loss Study on 7 MW Fully Superconducting Direct-Drive Wind Turbine Generators With Concentrated Stator Winding
    Koester, Robin
    Binder, Andreas
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (03) : 1 - 7