Hygroscopic dilators vs balloon catheter ripening of the cervix for induction of labor in nulliparous women at term: Retrospective study

被引:11
|
作者
Shindo, Ryosuke [1 ,5 ]
Aoki, Shigeru [1 ]
Yonemoto, Naohiro [2 ,3 ,6 ,7 ]
Yamamoto, Yuriko [1 ]
Kasai, Junko [1 ]
Kasai, Michi [1 ]
Miyagi, Etsuko [4 ]
机构
[1] Yokohama City Univ, Med Ctr, Perinatal Ctr Matern & Neonate, Yokohama, Kanagawa, Japan
[2] Yokohama City Univ, Grad Sch Med, Dept Biostat & Epidemiol, Yokohama, Kanagawa, Japan
[3] Univ Med Ctr, Yokohama, Kanagawa, Japan
[4] Yokohama City Univ, Sch Med, Dept Obstet & Gynecol, Yokohama, Kanagawa, Japan
[5] Yokosuka Kyosai Hosp, Dept Obstet & Gynecol, Yokosuka, Kanagawa, Japan
[6] Kyoto Univ, Grad Sch Med, Dept Biostat, Kyoto, Japan
[7] Kyoto Univ, Fac Med, Kyoto, Japan
来源
PLOS ONE | 2017年 / 12卷 / 12期
关键词
RANDOMIZED-CONTROLLED-TRIAL; UMBILICAL-CORD PROLAPSE; TRANSCERVICAL FOLEY CATHETER; JAPAN; DINOPROSTONE; METAANALYSIS; RISK; GEL;
D O I
10.1371/journal.pone.0189665
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective To compare the efficacy and safety of hygroscopic dilators and balloon catheters for ripening of the cervix in induction of labor. Study design This retrospective, observational study used data from the Successive Pregnancy Birth Registry System of the Japan Society of Obstetrics and Gynecology from 2012 to 2014. Nulliparous women in whom labor was induced by mechanical methods of cervical ripening at term were enrolled. The eligible women were divided into dilator, balloon <40 mL, balloon. 40 mL, and overlapping groups. Results The groups included 4645, 4100, 6615, and 1992 women, respectively. In the overlapping group, which included the women in whom delivery was most difficult, the vaginal delivery rate was lower and the intrauterine infection and neonatal mortality rates were higher than those in the dilator group. No difference in the vaginal delivery rate was observed among the dilator, balloon <40 mL, and balloon. 40 mL groups (74.6%, 72.3%, and 73.8%, respectively; p>0.05). The vaginal instrumental delivery rate was higher in the two-balloon groups than in the dilator group. The volume of intrapartum hemorrhage was lowest in the dilator group. No significant difference in the frequencies of uterine rupture and intrauterine infection were observed among the dilator and two-balloon groups. With regard to neonatal outcomes, the frequency of a low Apgar score was statistically significantly lower in the dilator group than in the two-balloon groups. Moreover, the frequency of neonatal death tended to be lower in the dilator group than in the two-balloon groups. Conclusion With regard to cervical ripening for labor induction in nulliparous women at term, the vaginal delivery rate on using a dilator and on using a balloon seems to be equivalent. Concerning maternal complications and neonatal outcomes, cervical ripening with hygroscopic dilators in labor induction might be safer.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [1] Synthetic osmotic dilators dilapan-s vs double balloon catheter ripening of the cervix for induction of labour in nulliparous
    Baev, O.
    Babich, D.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2022, 270 : E120 - E121
  • [2] Labor induction in nulliparous women with an unfavorable cervix: double balloon catheter versus dinoprostone
    Suffecool, Katarzyna
    Rosenn, Barak M.
    Kam, Stefanie
    Mushi, Juliet
    Foroutan, Janelle
    Herrera, Kimberly
    JOURNAL OF PERINATAL MEDICINE, 2014, 42 (02) : 213 - 218
  • [3] Balloon catheter for induction of labor in nulliparous women with prelabor rupture of the membranes at term
    Wolff, KS
    Swahn, ML
    Westgren, M
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1998, 46 (01) : 1 - 4
  • [4] Balloon catheter vs oxytocin alone for induction of labor in women with one previous cesarean section and an unfavorable cervix: a multicenter, retrospective study
    Secchi, Deborah
    Alberic, Julia
    Gobillot, Sophie
    Ghenassia, Adrien
    Roustit, Matthieu
    Chauleur, Celine
    Hoffmann, Pascale
    Raia-Barjat, Tiphaine
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2022, 306 (02) : 379 - 387
  • [5] Balloon catheter vs oxytocin alone for induction of labor in women with one previous cesarean section and an unfavorable cervix: a multicenter, retrospective study
    Déborah Secchi
    Julia Albéric
    Sophie Gobillot
    Adrien Ghenassia
    Matthieu Roustit
    Céline Chauleur
    Pascale Hoffmann
    Tiphaine Raia-Barjat
    Archives of Gynecology and Obstetrics, 2022, 306 : 379 - 387
  • [6] The efficacy of early amniotomy after ripening with Foley balloon catheter in nulliparous labor induction
    Battarbee, Ashley
    Palatnik, Anna
    Peress, Danielle
    Grobman, William
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 214 (01) : S268 - S269
  • [7] Effect of Obesity on Outcomes in Nulliparous Women Undergoing Balloon Ripening for Labor Induction
    Saylawala, Maliha A.
    Horton, Amanda
    OBSTETRICS AND GYNECOLOGY, 2014, 123 : 77S - 77S
  • [8] Association of Early Amniotomy After Foley Balloon Catheter Ripening and Duration of Nulliparous Labor Induction
    Battarbee, Ashley N.
    Palatnik, Anna
    Peress, Danielle A.
    Grobman, William A.
    OBSTETRICS AND GYNECOLOGY, 2016, 128 (03): : 592 - 597
  • [9] Pre-cervical ripening and hygroscopic cervical dilators in pre-labor induction
    D'Indinosante, Marco
    Vidiri, Annalisa
    Giorgi, Laura
    Turrini, Irene
    Spano, Amelia
    Perelli, Federica
    Scatena, Elisa
    Mattei, Alberto
    Lanzone, Antonio
    Scambia, Giovanni
    Cavaliere, Annafranca
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2023, 36 (02):
  • [10] The Association between Cervical Exam after Ripening with Foley Balloon Catheter and Outcomes of Nulliparous Labor Induction
    Battarbee, Ashley N.
    Palatnik, Anna
    Peress, Danielle A.
    Grobman, William A.
    AMERICAN JOURNAL OF PERINATOLOGY, 2018, 35 (10) : 1001 - 1005