Parameters impact on the performance of a double-fed induction generator-based wind turbine for subsynchronous resonance control

被引:41
|
作者
Zhu, C. [1 ]
Hu, M. [1 ]
Wu, Z. [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
SYNCHRONOUS SERIES COMPENSATOR; SSR; MITIGATION;
D O I
10.1049/iet-rpg.2010.0138
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With increasing wind power in power systems, impact of subsynchronous resonance (SSR) on wind generator is of interest. This study presents the models of a double-fed induction generator (DFIG)-based wind turbine in a series-compensated network for SSR study. For DFIG (induction machine), the induction generator effect (IGE) is the most important factor of SSR. The control scheme for IGE is proposed in this study and the impact of the control parameters is also studied in detail. Eigenvalue analysis is conducted to study the impact of wind speeds, series compensation levels and control scheme on IGE phenomena. Time-domain simulations are performed in Matlab/Simulink to confirm the analysis.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 50 条
  • [41] Adaptive direct power control for double fed induction generator used in wind turbine
    Mazouz, Farida
    Belkacem, Sebti
    Colak, Ilhami
    Drid, Said
    Harbouche, Youcef
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 114 (114)
  • [42] Artificial Intelligence Control System Applied in Smart Grid Integrated Doubly Fed Induction Generator-Based Wind Turbine: A Review
    Behara, Ramesh Kumar
    Saha, Akshay Kumar
    ENERGIES, 2022, 15 (17)
  • [43] Subsynchronous oscillation and its mitigation of VSC-MTDC with doubly-fed induction generator-based wind farm integration
    Su, Miaohong
    Dong, Haiying
    Liu, Kaiqi
    Zou, Weiwei
    ARCHIVES OF ELECTRICAL ENGINEERING, 2021, 70 (01) : 53 - 72
  • [44] Multi-Area Hydrothermal Interconnected Load Frequency Control with Double-Fed Induction-Generator-Based Wind Turbine via Improved Harmony Algorithm
    Abo-Elyousr, Farag K.
    Youssef, Ali M.
    Abdelaziz, Almoataz Y.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2018, 46 (06) : 615 - 628
  • [45] Sub-Synchronous Range of Operation for a Wind Driven Double-Fed Induction Generator
    Saleh, Mahmoud Abdel Halim
    Eskander, Mona Naguib
    JOURNAL OF POWER ELECTRONICS, 2010, 10 (01) : 72 - 78
  • [46] Fuzzy-logic control system of a variable-speed variable-pitch wind-turbine and a double-fed induction generator
    Amendola, C. A. M.
    Gonzaga, D. P.
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND APPLICATIONS, 2007, : 252 - 257
  • [47] Simulation on frequency control of doubly fed induction generator based wind turbine
    China Electric Power Research Institute, Beijing 100085, China
    不详
    Dianli Xitong Zidonghue, 2007, 7 (61-65): : 61 - 65
  • [48] DIRECT POWER CONTROL OF DOUBLE-FED INDUCTION GENERATOR BASED ON IMPROVED SUPER-TWISTING
    Li, Shengqing
    Wen, Yanxi
    Huang, Yuanpeng
    Zhou, Zhifei
    Chen, Xin
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (10): : 529 - 535
  • [49] Sliding-mode control of a wind turbine-driven double-fed induction generator under non-ideal grid voltages
    Itsaso Martinez, Miren
    Susperregui, Ana
    Tapia, Gerardo
    Xu, Lie
    IET RENEWABLE POWER GENERATION, 2013, 7 (04) : 370 - 379
  • [50] Modeling and control of a Wind Turbine Plant based on Doubly Fed Induction Generator
    Tlijani, Sofien
    Meddeb, Asma
    Chebbi, Souad
    2019 10TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2019,