Permanent Epicardial Pacing in Pediatric Patients: 12-Year Experience at a Single Center

被引:29
|
作者
Kwak, Jae Gun
Kim, Soo-Jin
Song, Jin Young
Choi, Eun Young
Lee, Sang Yoon
Shim, Woo Sup
Lee, Chang-Ha
Lee, Cheul
Park, Chun Soo
机构
[1] Sejong Gen Hosp, Dept Thorac & Cardiovasc Surg, Puchon, South Korea
[2] Konkuk Univ, Dept Pediat, Sch Med, Div Pediat Cardiol, Seoul, South Korea
[3] Sejong Gen Hosp, Dept Pediat, Puchon, South Korea
来源
ANNALS OF THORACIC SURGERY | 2012年 / 93卷 / 02期
关键词
CONGENITAL HEART-DISEASE; PACEMAKER IMPLANTATION; ENDOCARDIAL LEADS; LATE RECOVERY; YOUNG-ADULTS; FOLLOW-UP; CHILDREN; INFANTS; LONGEVITY; THERAPY;
D O I
10.1016/j.athoracsur.2011.09.072
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Permanent cardiac pacing is not often done in children, and when done is usually accomplished through epicardial pacing. We reviewed a 12-year experience with the implantation of epicardial pacemakers by our clinical group. Methods. Fifty-three patients who underwent their first implantation of an epicardial pacemaker before the age of 18 years and between 1997 and 2009 were included in our study. The mean age of the patients at the time of first pacemaker implantation was 5.7 +/- 4.8 years. Indications for pacemaker implantation included postoperative or congenital atrioventricular block and sinus node dysfunction. The patients underwent 105 operations for the replacement of pacemaker pulse generators and 75 operations for the replacement of pacemaker leads. The most commonly used generator mode was the rate-responsive accelerometer-based (DDDR) mode, which was used in 40.9% of the patients. We used more non-steroid-eluting leads (70.1%) than steroid-eluting leads (29.1%). Results. The overall duration of follow-up in the study was 8.0 +/- 4.5 years (range, 2.1 months to approximately 17.0 years). Freedom from the need for generator replacement was 98.0%, 60.7%, and 11.1% at 1, 5, and 8 years, respectively. A tendency toward early generator exhaustion was observed among younger patients (p = 0.058). The generator mode used for pacing did not significantly affect generator longevity. Freedom from the need for lead replacement was 98.3%, 83.8%, and 63.6% at 1, 5, and 10 years, respectively. The mean longevity of the leads used in the study was 10.8 +/- 0.8 years. Neither patient age at the time of lead implantation nor type of lead significantly affected lead longevity. Conclusions. Lead longevity was sufficiently long and did not vary significantly according to type of lead. Generator longevity was not affected by lead type, generator mode, or patient age at the time of pacemaker implantation. (Ann Thorac Surg 2012;93:634-40) (C) 2012 by The Society of Thoracic Surgeons
引用
收藏
页码:634 / 640
页数:7
相关论文
共 50 条
  • [21] Coronary artery fistulas: A 12-year single-center experience
    Torres, Sofia
    Vasconcelos, Mariana
    Silva, Marta Tavares
    Moreira, Jorge
    Silva, Joao Carlos
    Macedo, Filipe
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2022, 41 (10) : 843 - 850
  • [22] Reappraisal of Central Pancreatectomy A 12-Year Single-Center Experience
    Goudard, Yvain
    Gaujoux, Sebastien
    Dockmak, Safi
    Cros, Jerome
    Couvelard, Anne
    Palazzo, Maxime
    Ronot, Maxime
    Vullierme, Marie-Pierre
    Ruszniewski, Philippe
    Belghiti, Jacques
    Sauvanet, Alain
    JAMA SURGERY, 2014, 149 (04) : 356 - 363
  • [23] TRANSPLANTATION OF SINGLE PEDIATRIC KIDNEYS INTO ADULT RECIPIENTS - A 12-YEAR EXPERIENCE
    ABOUNA, G
    KUMAR, MSA
    CHVALA, R
    MCSORLEY, M
    SAMHAN, M
    TRANSPLANTATION PROCEEDINGS, 1995, 27 (05) : 2564 - 2566
  • [24] Clinical and Demographic Features of 195 Pediatric Patients with Henoch-Schonlein Purpura, 12-Year Single Center Experience in Shiraz
    Esmaeilzadeh, Hossein
    Masoudi, Seyed Alireza
    Ebrahimi, Narjes
    Alyasin, Soheyla
    Nabavizadeh, Hesamodin
    ARCHIVES OF PEDIATRIC INFECTIOUS DISEASES, 2020, 8 (04): : 1 - 6
  • [25] Early Versus Late Tracheostomy in Cardiac Surgical Patients: A 12-Year Single Center Experience
    Affronti, Alessandro
    Casali, Francesco
    Eusebi, Paolo
    Todisco, Cristina
    Volpi, Francesca
    Beato, Virginia
    Manini, Emilia Virginia
    Scopetani, Giulia
    Ragni, Temistocle
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (01) : 82 - 90
  • [26] Epicardial pacing wires, a five year, single centre experience
    J Abbas
    K Toombs
    A Zaidi
    JA Hoschtitzky
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [27] Minimally invasive aortic valve replacement: 12-year single center experience
    Gilmanov, Daniyar
    Solinas, Marco
    Farneti, Pier Andrea
    Cerillo, Alfredo Giuseppe
    Kallushi, Enkel
    Santarelli, Filippo
    Glauber, Mattia
    ANNALS OF CARDIOTHORACIC SURGERY, 2015, 4 (02) : 160 - 169
  • [28] Carotid Artery Stenting: Analysis of a 12-Year Single-Center Experience
    Fanelli, Fabrizio
    Boatta, Emanuele
    Cannavale, Alessandro
    Corona, Mario
    Lucatelli, Pierleone
    Wlderk, Andrea
    Cirelli, Carlo
    Salvatori, Filippo M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (06) : 749 - 756
  • [29] Differentiated Thyroid Cancer in Children and Adolescents: 12-year Experience in a Single Center
    Puga, Francisca Marques
    Correia, Laura
    Vieira, Ines
    Caetano, Joana Serra
    Cardoso, Rita
    Dinis, Isabel
    Mirante, Alice
    JOURNAL OF CLINICAL RESEARCH IN PEDIATRIC ENDOCRINOLOGY, 2024, 16 (03) : 314 - 322
  • [30] Chest wall resection for lung cancer: A 12-year experience in a single center
    Ucvet, Ahmet
    Batihan, Guntug
    Yazgan, Serkan
    Ceylan, Kenan Can
    Gursoy, Soner
    Kaya, Seyda Ors
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58