Compensation of Unbalanced Low-Voltage Grids Using a Photovoltaic Generation System with a Dual Four-Leg, Two-Level Inverter

被引:4
|
作者
Fernao Pires, Vitor [1 ,2 ]
Cordeiro, Armando [1 ,2 ,3 ]
Foito, Daniel [1 ,4 ]
Jose Pires, Armando [1 ,4 ]
Hao, Chen [5 ]
Francisco Martins, Joao [4 ,6 ]
Castro, Rui [2 ,7 ]
机构
[1] Polytech Inst Setubal, SustainRD, ESTSetubal, P-2914508 Setubal, Portugal
[2] INESC ID, P-1049001 Lisbon, Portugal
[3] ISEL Inst Politecn Lisboa, P-1959007 Lisbon, Portugal
[4] CTS UNINOVA, P-2829516 Caparica, Portugal
[5] China Univ Min & Technol, Sch Elect & Power Engn, Xuzhou 221116, Jiangsu, Peoples R China
[6] Univ Nova Lisboa, Fac Sci & Technol, P-1049001 Lisbon, Portugal
[7] Univ Lisbon, IST, P-1049001 Lisbon, Portugal
关键词
low-voltage grid; unbalanced load; grid support; dual inverter; multilevel inverter; photovoltaic system (PV); MULTILEVEL INVERTER; PERFORMANCE; CONVERTERS; EFFICIENCY; HARMONICS; STRATEGY; SINGLE; PLANTS; PWM;
D O I
10.3390/electronics11030320
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a grid-connected photovoltaic (PV) generation system is proposed with the purpose of providing support to low-voltage grids, namely through the elimination or attenuation of the grid imbalances. This compensation must consider the load types, which can be either linear or non-linear, and whether the reactive power and current harmonics generated by the non-linear loads need to be compensated in addition to the unbalanced active power. This must be well considered, since the compensation of all aspects requires oversized PV inverters. Thus, the different unbalanced compensation schemes are addressed. Several schemes for the generation of the inverter current references taking into consideration the compensation and load type are presented. For this PV generation system, a dual four-leg, two-level inverter is proposed. It provides full unbalanced compensation owing to the fourth leg of the inverter and also extends the AC voltage, which is important when this compensation is required. To control this inverter, a control scheme for the inverter that considers several compensation factors is proposed. A vector voltage modulator associated with the controller is another aspect that is addressed in the paper. This modulator considers the balance between the DC voltages of the inverters. Several compensation schemes are verified through computational tests. The results validate the effectiveness of the proposed PV generation system.
引用
收藏
页数:25
相关论文
共 41 条
  • [21] Design and Application of a Five-Level Cross-Switched Inverter in Low-Voltage Distribution System Voltage Compensation
    Farhadi-Kangarlu, Mohammad
    Neyshabouri, Yousef
    Sotudeh, Asra
    [J]. 2021 29TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2021, : 274 - 278
  • [22] Study on the Current-Limiting-Capable Control Strategy for Grid-Connected Three-Phase Four-Leg Inverter in Low-Voltage Network
    Li, Botong
    Jia, Jianfei
    Xue, Shimin
    [J]. ENERGIES, 2016, 9 (09)
  • [23] A Three-Phase Four-Leg Inverter-Based Active Power Filter for Unbalanced Current Compensation Using a Petri Probabilistic Fuzzy Neural Network
    Tan, Kuang-Hsiung
    Lin, Faa-Jeng
    Chen, Jun-Hao
    [J]. ENERGIES, 2017, 10 (12)
  • [24] A Grid-Connected PV System with Power Quality Improvement Based on Boost plus Dual-Level Four-Leg Inverter
    Li, Jing
    Zhuo, Fang
    Wang, Xianwei
    Wang, Lin
    Ni, Song
    [J]. 2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1265 - +
  • [25] Enhancement of Line-to-Line Voltage Support During Asymmetrical Microgrid Faults Using a Four-Leg Three-Level Inverter
    Mohapatra, Soumya Ranjan
    Agarwal, Vivek
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2022, 13 (02) : 1298 - 1309
  • [26] Multi-objective Particle Swarm Optimization-Based Placement and Sizing of Distributed Generators Integrated to Unbalanced Low-Voltage Microgrids by Four-Leg Inverters
    Das G.
    Hazarika D.
    [J]. Journal of The Institution of Engineers (India): Series B, 2023, 104 (03) : 731 - 747
  • [27] Multilevel Inverter Based Single-Stage Grid Connected Photovoltaic System using Cascaded Two-Level Inverter
    Shah, Nilesh
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2018,
  • [28] Low-Voltage Ride-Through Techniques for Two-Stage Photovoltaic System under Unbalanced Grid Voltage Sag Conditions
    Lin, Xiangyang
    Han, Yang
    Yang, Ping
    Wang, Congling
    Xiong, Jingqi
    [J]. 2018 IEEE 4TH SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2018,
  • [29] Research on methods of reactive compensation for unbalanced current in three-phase four-wire low-voltage distribution system
    Zhu, Xue-ling
    Cao, Wen-si
    Zhou, Xiao-ming
    [J]. RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 1156 - 1160
  • [30] GaN Four-leg Inverter Implementing Novel Common Mode Elimination using a Hardware-in-the-loop System-Level Controller
    Li, Caleb
    von Jouanne, Annette
    Oriti, Giovanna
    Julian, Alex
    Agamloh, Emmanuel
    Yokochi, Alex
    [J]. 2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,