HPLC-electrochemical detection with graphite-poly(tetrafluoroethylene) electrode - Determination of the fungicides thiram and disulfiram

被引:52
|
作者
Fernandez, C [1 ]
Reviejo, AJ [1 ]
Polo, LM [1 ]
Pingarron, JM [1 ]
机构
[1] UNIV COMPLUTENSE MADRID,FAC CHEM,DEPT ANALYT CHEM,E-28040 MADRID,SPAIN
关键词
composite electrodes; disulfiram; graphite-teflon; HPLC; thiram;
D O I
10.1016/0039-9140(96)01899-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The suitability of composite graphite-poly(tetrafluoroethylene) (Teflon) electrodes as amperometric indicator electrodes in HPLC detection is demonstrated. The determination of the fungicides thiram and disulfiram in the presence of ziram has been chosen as an analytical problem. The optimization of working conditions, such as the choice of the organic solvent used in the mobile phase as well as its percentage, the potential applied to the composite electrode, and the time elapsed between mixing the carbamates and the injection, has been accomplished by using the wall-jet flow-cell configuration. The effect of the acetonitrile percentage used in the mobile phase on the retention of thiram, disulfiram, ziram and phenol was evaluated. Resolution up to the baseline can be achieved with 45% acetonitrile. The sensitivity of the determination of thiram and disulfiram in the presence of a constant concentration of ziram is slightly better when using a wall-jet cell; however, the background current is higher, as well as the baseline noise and the time necessary to achieve stabilization of the baseline before the injection. Lower limits of detection for both fungicides, as well as a better repeatability, were obtained when using a thin-layer flow cell configuration. As an application, the determination of thiram in spiked apple samples, at a level of 0.5 mg thiram kg(-1) apple, has been carried out with a mean recovery of 97 +/- 3% for a significance level of 0.05.
引用
收藏
页码:1341 / 1348
页数:8
相关论文
共 48 条
  • [21] Fabrication of Poly (Evans blue) Modified Graphite Paste Electrode as an Electrochemical Sensor for Sensitive and Instant Riboflavin Detection
    Charithra, M. M.
    Manjunatha, J. G.
    MOROCCAN JOURNAL OF CHEMISTRY, 2021, 9 (01): : 7 - 17
  • [22] Determination of nitric oxide in rats by HPLC with multi-electrode electrochemical coulometric-array detection
    Yoshimura, Y
    Ishii, Y
    Nakazawa, H
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (05) : 799 - 811
  • [23] Poly-5-Amino-1-naphthol modified pencil graphite electrode for the simultaneous electrochemical determination of Pyridoxine and Riboflavin
    Sajeevan B.
    MG G.
    Sreelekshmi
    Wilson A.
    Narayan Pillai A.
    Saraswathyamma B.
    Materials Today: Proceedings, 2023, 80 : 570 - 576
  • [24] Signal-Enhanced Electrochemical Determination of Quercetin with Poly(chromotrope fb)-Modified Pencil Graphite Electrode in Vegetables and Fruits
    Liv, Lokman
    Karakus, Erman
    ACS OMEGA, 2023, 8 (13): : 12522 - 12531
  • [25] Poly(propyleneimine) Dendrimer-Gold Nanoparticle Modified Exfoliated Graphite Electrode for the Electrochemical Detection of o-nitrophenol
    Ndlovu, Thabile
    Arotiba, Omotayo A.
    Mamba, Bhekie B.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 8330 - 8339
  • [26] Determination of resveratrol in grains, hulls and leaves of common and tartary buckwheat by HPLC with electrochemical detection at carbon paste electrode
    Nemcova, Lenka
    Zima, Jiri
    Barek, Jiri
    Janovska, Dagmar
    FOOD CHEMISTRY, 2011, 126 (01) : 374 - 378
  • [27] Electrochemical determination of dinitramine in water samples using a pencil graphite electrode modified with poly-l-cystein-gold nanoparticle
    Amouzad, Fatemeh
    Zarei, Kobra
    CHEMICAL PAPERS, 2021, 75 (02) : 493 - 501
  • [28] Electrochemical determination of dinitramine in water samples using a pencil graphite electrode modified with poly-l-cystein-gold nanoparticle
    Fatemeh Amouzad
    Kobra Zarei
    Chemical Papers, 2021, 75 : 493 - 501
  • [29] HPLC Determination of Aminobiphenyls in Drinking and River Water Using Electrochemical Detection with Boron-Doped Diamond Film Electrode
    Maixnerova, Lucie
    Peckova, Karolina
    Barek, Jiri
    Klimova, Helena
    CHEMICKE LISTY, 2010, 104 (03): : 191 - 196
  • [30] Determination of 1-hydroxypyrene in human urine by HPLC with electrochemical detection at a boron-doped diamond film electrode
    Oksana Yosypchuk
    Jiří Barek
    Vlastimil Vyskočil
    Analytical and Bioanalytical Chemistry, 2012, 404 : 693 - 699