HPLC-electrochemical detection with graphite-poly(tetrafluoroethylene) electrode - Determination of the fungicides thiram and disulfiram

被引:52
|
作者
Fernandez, C [1 ]
Reviejo, AJ [1 ]
Polo, LM [1 ]
Pingarron, JM [1 ]
机构
[1] UNIV COMPLUTENSE MADRID,FAC CHEM,DEPT ANALYT CHEM,E-28040 MADRID,SPAIN
关键词
composite electrodes; disulfiram; graphite-teflon; HPLC; thiram;
D O I
10.1016/0039-9140(96)01899-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The suitability of composite graphite-poly(tetrafluoroethylene) (Teflon) electrodes as amperometric indicator electrodes in HPLC detection is demonstrated. The determination of the fungicides thiram and disulfiram in the presence of ziram has been chosen as an analytical problem. The optimization of working conditions, such as the choice of the organic solvent used in the mobile phase as well as its percentage, the potential applied to the composite electrode, and the time elapsed between mixing the carbamates and the injection, has been accomplished by using the wall-jet flow-cell configuration. The effect of the acetonitrile percentage used in the mobile phase on the retention of thiram, disulfiram, ziram and phenol was evaluated. Resolution up to the baseline can be achieved with 45% acetonitrile. The sensitivity of the determination of thiram and disulfiram in the presence of a constant concentration of ziram is slightly better when using a wall-jet cell; however, the background current is higher, as well as the baseline noise and the time necessary to achieve stabilization of the baseline before the injection. Lower limits of detection for both fungicides, as well as a better repeatability, were obtained when using a thin-layer flow cell configuration. As an application, the determination of thiram in spiked apple samples, at a level of 0.5 mg thiram kg(-1) apple, has been carried out with a mean recovery of 97 +/- 3% for a significance level of 0.05.
引用
收藏
页码:1341 / 1348
页数:8
相关论文
共 48 条
  • [1] DEVELOPMENT OF GRAPHITE-POLY(TETRAFLUOROETHYLENE) COMPOSITE ELECTRODES - VOLTAMMETRIC DETERMINATION OF THE HERBICIDES THIRAM AND DISULFIRAM
    FERNANDEZ, C
    REVIEJO, AJ
    PINGARRON, JM
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 192 - 199
  • [2] GRAPHITE-POLY(TETRAFLUOROETHYLENE) ELECTRODES AS ELECTROCHEMICAL DETECTORS IN FLOWING SYSTEMS
    FERNANDEZ, C
    REVIEJO, AJ
    PINGARRON, JM
    ANALYTICA CHIMICA ACTA, 1995, 314 (1-2) : 13 - 22
  • [3] A novel electrode material that extends the utility of HPLC-electrochemical detection
    Vivo Valtammetry, ESA Biosciences, Inc., 22 Alpha Rd., Chehnford, MA 01824, United States
    不详
    不详
    Am Lab, 2007, 14 (38-41+10):
  • [4] A novel electrode material that extends the utility of HPLC-electrochemical detection
    Waraska, John
    Acworth, M.
    AMERICAN LABORATORY, 2007, 39 (14) : 38 - +
  • [5] ng/1 level of BPA determination existing in natural water with HPLC-electrochemical detection
    Watabe, Y
    Hosoya, K
    Tanaka, N
    Kondo, T
    Imai, H
    Morita, M
    BUNSEKI KAGAKU, 2003, 52 (12) : 1167 - 1172
  • [6] A novel HPLC-electrochemical detection approach for the determination of D-penicillamine in skin specimens
    Saracino, Maria A.
    Cannistraci, Cristina
    Bugamelli, Francesca
    Morganti, Emanuele
    Neri, Iria
    Balestri, Riccardo
    Patrizi, Annalisa
    Raggi, Maria A.
    TALANTA, 2013, 103 : 355 - 360
  • [7] Elucidation and Characterization of New Chlorinated By-Products after Electrochemical Degradation of Hydrochlorothiazide Using Graphite-Poly Vinyl Chloride Electrode
    Mussa, Zainab Haider
    Al-Qaim, Fouad Fadhil
    Yuzir, Ali
    Hara, Hirofumi
    Azman, Shamila
    Chelliapan, Shreeshivadasan
    CATALYSTS, 2018, 8 (11):
  • [8] Integration of a graphite/poly(methylmethacrylate) composite electrode into a poly(methylmethacrylate) substrate for electrochemical detection in microchips
    Regel, Anne
    Lunte, Susan
    ELECTROPHORESIS, 2013, 34 (14) : 2101 - 2106
  • [9] Electrochemical Determination of Mesalazine by Modified Graphite Paste Electrode with Poly (Benzoquinone) Chromium(III) Complex
    Nouri, Arezo
    Noroozifar, Meissam
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2018, 5 (02): : 343 - 352
  • [10] 6 CHANNEL ELECTROCHEMICAL HPLC DETECTOR USING GRAPHITE REINFORCEMENT CARBON ELECTRODE FOR DETERMINATION OF CATECHOLAMINE METABOLITES
    KUSU, F
    TAKAGI, H
    YUASA, K
    TAKAMURA, K
    BUNSEKI KAGAKU, 1992, 41 (10) : 497 - 502