Development of a bioactive surface on a Co-Cr-Mo alloy during investment casting or heat treatment

被引:1
|
作者
Ortiz-Cuellar, J. C. [1 ]
Cortes-Hernandez, D. A. [1 ]
Escobedo-Bocardo, J. C. [1 ]
Robles, J. M. Almanza [1 ]
机构
[1] CINVESTAV, Unidad Saltillo, Carr Saltillo Mty Km 13,Apdo Postal 663, Saltillo 25000, Coahuila, Mexico
来源
BIOCERAMICS, VOL 20, PTS 1 AND 2 | 2008年 / 361-363卷
关键词
cobalt base alloys; coatings; bioactivity; apatite layer; SBF;
D O I
10.4028/www.scientific.net/KEM.361-363.653
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Two different techniques were used to promote a bioactive surface on a cobalt base alloy: i) the cobalt alloy melt was cast into wollastonite-coated cavities of an investment mold, or ii) wollasonite-encapsulated as-cast samples were heat treated at 1220 degrees C for 1 h, this is the typical treatment performed to this alloy for improving its mechanical behavior. In vitro bioactivity was assessed by immersing samples in a simulated body fluid for 21 days. Potentially bioactive layers were obtained in both of the cases. A thicker apatite layer was formed oil the samples obtained by investment casting. However, since the heat treatment needs to be performed, the heat treatment method is also a promising technique for promoting the bone-bonding ability of this Co alloy.
引用
收藏
页码:653 / +
页数:2
相关论文
共 50 条
  • [41] An effective method of edge deburring for laser surface texturing of Co-Cr-Mo alloy
    Guo, Junde
    Li, Yue
    Lu, Hailin
    Qin, Liguo
    Li, Yu
    Dong, Guangneng
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2018, 94 (1-4): : 1491 - 1503
  • [42] Investigation of laser surface texturing parameters of biomedical grade Co-Cr-Mo alloy
    Şefika Kasman
    İbrahim Can Uçar
    Sertan Ozan
    The International Journal of Advanced Manufacturing Technology, 2023, 125 : 4271 - 4291
  • [43] Development of microstructure and mechanical properties during annealing of a cold-swaged Co-Cr-Mo alloy rod
    Mori, Manami
    Sato, Nanae
    Yamanaka, Kenta
    Yoshida, Kazuo
    Kuramoto, Koji
    Chiba, Akihiko
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 64 : 187 - 198
  • [44] The advanced characterization of a new alloy by Co-Cr-Mo system
    Minciuna, M. G.
    Vizureanu, P.
    Achitei, D. C.
    Sandu, A. V.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2016, 18 (7-8): : 717 - 722
  • [45] A dispersion strengthened Co-Cr-Mo alloy for medical implants
    Wang, KK
    Berlin, RM
    Gustavson, LJ
    COBALT-BASE ALLOYS FOR BIOMEDICAL APPLICATIONS, 1999, 1365 : 89 - 97
  • [46] Passivation and mechanical property improvement of Co-Cr-Mo alloy
    Guo, Feifei
    Dong, Guangneng
    Dong, Guangneng, 1600, Science Press (34): : 1197 - 1201
  • [47] CUTTING CHARACTERISTICS OF CO-CR-MO ALLOY BIOCOMPATIBLE MATERIALS
    Hagino, Masahiro
    Su, Xin
    Inoue, Takashi
    PROGRESS OF MACHINING TECHNOLOGY, 2012, : 19 - 22
  • [48] Effect of the Remelting on Transformations in Co-Cr-Mo Prosthetics Alloy
    Kacprzyk, B.
    Szymczak, T.
    Gumienny, G.
    Klimek, L.
    ARCHIVES OF FOUNDRY ENGINEERING, 2013, 13 (03) : 47 - 50
  • [49] Study of passivation of Co-Cr-Mo alloy in physiologic serum
    Ramires, I.
    Rocha, L.
    Codaro, E.N.
    Guastaldi, A.C.
    Informacion Tecnologica, 1999, 10 (05): : 61 - 65
  • [50] CORROSION RESISTANCE OF Co-Cr-Mo ALLOY USED IN DENTISTRY
    Lukaszczyk, A.
    Augustyn-Pieniazek, J.
    ARCHIVES OF METALLURGY AND MATERIALS, 2015, 60 (01) : 523 - 528