Reliability of cephalometric superimposition for the assessment of craniofacial changes: a systematic review

被引:14
|
作者
Graf, Carmen Camila [1 ]
Dritsas, Konstantinos [1 ]
Ghamri, Mohammed [1 ,2 ]
Gkantidis, Nikolaos [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Orthodont & Dentofacial Orthoped, Bern, Switzerland
[2] Minist Hlth, Directorate Hlth Affairs Jeddah, Riyadh, Saudi Arabia
关键词
CRANIAL BASE; MANDIBULAR SUPERIMPOSITION; GROWTH CHANGES; HEAD POSTURE; IMPLANT; MAXILLARY; CEPHALOGRAMS; DISPLACEMENT; ACCURACY; REPRODUCIBILITY;
D O I
10.1093/ejo/cjab082
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Superimposition of serial cephalometric radiographs enables the assessment of craniofacial changes over time, and therefore, several methods have been suggested in the literature. Objective The aim of the present study is to summarize and critically evaluate the available evidence on the reliability of methods used to superimpose serial cephalometric radiographs. Search methods Electronic searches were performed in MEDLINE, EMBASE, Google Scholar, and Cochrane Databases, without time limit (last update: 1 November 2020). Unpublished literature was searched on the Open Grey and Grey Literature Report databases. Selection criteria Studies that tested the accuracy, precision, or agreement between different cephalometric superimposition techniques, used to evaluate the craniofacial changes due treatment or growth. Data collection and analysis Reference lists of relevant articles were screened and authors were contacted, if needed. All study selection steps, data extraction, and risk of bias (QUADAS-2 tool) assessments were performed independently by two authors on predefined forms. Results There were 27 eligible studies. From these, 17 tested superimpositions methods on the anterior cranial base, 10 on the maxilla and 12 on the mandible. There were three studies that compared superimpositions on the cranial base with those on the maxilla and one that compared the cranial base with the mandibular superimposition. There was high heterogeneity among studies in terms of sample size, growth, radiographic machines, selection criteria, superimposition methods, references, and outcomes measured. Furthermore, almost all studies presented important methodological limitations, with only two studies having unclear risk of bias and the rest 25 presenting high risk. Conclusions Currently, there is no cephalometric superimposition method that has been proved to deliver accurate results. There is an urgent need for further research in this topic, since this is a primary assessment method to assess craniofacial changes over time for several relevant disciplines. Registration PROSPERO (CRD42020200349).
引用
收藏
页码:477 / 490
页数:14
相关论文
共 50 条
  • [41] Feasibility and reliability of frailty assessment in the critically ill: a systematic review
    Pugh, Richard J.
    Ellison, Amy
    Pye, Kate
    Subbe, Christian P.
    Thorpe, Chris M.
    Lone, Nazir I.
    Clegg, Andrew
    CRITICAL CARE, 2018, 22
  • [42] Application of Bayesian networks in reliability assessment: A systematic literature review
    Wang, Qi-Ang
    Chen, Jin
    Ni, Yiqing
    Xiao, Yufeng
    Liu, Ningbo
    Liu, Shukui
    Feng, Wangsheng
    STRUCTURES, 2025, 71
  • [43] Reliability, validity, and responsiveness of pinch strength assessment: a systematic review
    Szekeres, Mike
    Aspinall, Duncan
    Kulick, Jennifer
    Sajid, Asma
    Dabbagh, Armaghan
    MacDermid, Joy
    DISABILITY AND REHABILITATION, 2024,
  • [44] Feasibility and reliability of frailty assessment in the critically ill: a systematic review
    Richard J. Pugh
    Amy Ellison
    Kate Pye
    Christian P. Subbe
    Chris M. Thorpe
    Nazir I. Lone
    Andrew Clegg
    Critical Care, 22
  • [45] Reliability of different three-dimensional cephalometric landmarks in cone-beam computed tomography: A systematic review
    Sam, Alycia
    Currie, Kris
    Oh, Heesoo
    Flores-Mir, Carlos
    Lagravere-Vich, Manuel
    ANGLE ORTHODONTIST, 2019, 89 (02) : 317 - 332
  • [46] Reliability and validity of a modified lateral cephalometric analysis for evaluation of craniofacial morphology and growth in patients with clefts - Discussion
    Salim, A
    Nacamuli, RP
    Longaker, MT
    JOURNAL OF CRANIOFACIAL SURGERY, 2004, 15 (03) : 413 - 414
  • [47] Comparison of the reliability of craniofacial anatomic landmarks based on cephalometric radiographs and three-dimensional CT scans
    Kragskov, J
    Bosch, C
    Gyldensted, C
    SindetPedersen, S
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 1997, 34 (02): : 111 - 116
  • [48] Cephalometric Superimposition on the Occipital Condyles as a Longitudinal Growth Assessment Reference: I-Point and I-Curve
    Standerwick, Richard
    Roberts, Eugene
    Hartsfield, James, Jr.
    Babler, William
    Kanomi, Ryuzo
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2008, 291 (12): : 1603 - 1610
  • [49] Craniofacial identification standards: A review of reliability, reproducibility, and implementation
    Wilkinson, Caroline
    Liu, Ching Yiu Jessica
    Shrimpton, Sarah
    Greenway, Elysia
    FORENSIC SCIENCE INTERNATIONAL, 2024, 359
  • [50] The corrugator supercilii for craniofacial reconstruction: a systematic review
    Mark Watke
    European Journal of Plastic Surgery, 2023, 46 : 327 - 333