The feasibility of long-term operation of SOFC is demonstrated with a short-stack with 2 anode supported cells at 700 degrees C at constant current density of 0.5 A/cm(2) over 30,000 hours resulting in a degradation rate in the order of 8 mV/kh on average. Reduction of the degradation rate to about 4 mV/kh is shown to be possible by selecting alternative manufacturing methods, as for instance atmospheric plasma spraying for the protective coating on interconnect steel.
引用
收藏
页码:187 / 194
页数:8
相关论文
共 50 条
  • [21] Thermo-mechanical and electrochemistry modeling of planar SOFC stacks
    Khaleel, MA
    Recknagle, KP
    Lin, Z
    Deibler, JE
    Chick, LA
    Stevenson, JW
    SOLID OXIDE FUEL CELLS VII (SOFC VII), 2001, 2001 (16): : 1032 - 1041
  • [22] MODELING OF ON-CELL REFORMING REACTION FOR PLANAR SOFC STACKS
    Yang, Choongmo
    Lim, Hyung-Tae
    Hwang, Soon Cheol
    Kim, Dohyung
    Lai, Kevin
    Koeppel, Brian J.
    Recknagle, Kurtis P.
    Khaleel, Moe A.
    PROCEEDINGS OF THE ASME 9TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY 2011, 2012, : 355 - 363
  • [23] Investigation of Impactors on Cell Degradation Inside Planar SOFC Stacks
    Guan, W. B.
    Jin, L.
    Ma, X.
    Wang, W. G.
    FUEL CELLS, 2012, 12 (06) : 1085 - 1094
  • [24] Efficient, long-term operation
    Leunig, Thomas
    Engineered Systems, 2013, 30 (11): : 10 - 13
  • [25] Long-term tests of DK-SOFC cells
    Barfod, R
    Koch, S
    Liu, YL
    Larsen, PH
    Hendriksen, PV
    SOLID OXIDE FUEL CELLS VIII (SOFC VIII), 2003, 2003 (07): : 1158 - 1166
  • [26] Influence of Sulfur on the long-term durability of SOFC cathode
    Liu, Run-ru
    Wang, De-jun
    Jing, Leng
    SENSORS, MECHATRONICS AND AUTOMATION, 2014, 511-512 : 81 - +
  • [27] DEVELOPMENT OF kW CLASS PLANAR TYPE SOFC STACKS AND A 5kW CLASS COGENERATION SYSTEM
    Lee, Taehee
    Choi, Jin Hyeok
    Choi, Mi-hwa
    Yoo, Young-Sung
    PROCEEDINGS OF THE ASME 8TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY 2010, VOL 1, 2010, : 333 - 336
  • [28] SOFC Long Term Operation in Pure Methane by Gradual Internal Reforming
    Georges, S.
    Bailly, N.
    Steil, M. C.
    Bultel, Y.
    Hadjar, A.
    Viricelle, J. P.
    Rieu, M.
    SOLID OXIDE FUEL CELLS 13 (SOFC-XIII), 2013, 57 (01): : 3023 - 3030
  • [29] Durability Tests of Flatten Tubular Segmented-in-Series Type SOFC Stacks for Intermediate Temperature Operation
    Horiuchi, K.
    Nakamura, K.
    Matsuzaki, M.
    Yamashita, S.
    Horita, T.
    Kishimoto, H.
    Yamaji, K.
    Yokokawa, H.
    SOLID OXIDE FUEL CELLS 12 (SOFC XII), 2011, 35 (01): : 217 - 223
  • [30] Glass sealing in planar SOFC stacks and chemcal stability of seal interfaces
    Yang, Z
    Xia, G
    Meinhardt, KD
    Weil, KS
    Stevenson, JW
    SURFACES, INTERFACES, AND THE SCIENCE OF CERAMIC JOINING, 2005, 158 : 135 - 146