Portable Pulse Meter with Simple Design

被引:0
|
作者
Lan, Tian-Syung [1 ,2 ]
Jiao, Yan [1 ]
Dai, Xuan-Jun [1 ]
Chen, Ho-Sheng [3 ]
Yang, Zhingqing [4 ]
机构
[1] Guilin Univ Technol, Coll Mech & Control Engn, Guilin 541004, Guangxi, Peoples R China
[2] Yu Da Univ Sci & Technol, Dept Informat Management, Miaoli 36143, Taiwan
[3] Guangdong Univ Petrochem Technol, Coll Mech & Elect Engn, Maoming 525000, Guangdong, Peoples R China
[4] Nanning Coll Technol, Nanning 541006, Guangxi, Peoples R China
关键词
MCU; LCD; infrared sensor; pulse signal;
D O I
10.18494/SAM.2021.3537
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We aim to propose a simple design of a pulse meter. Pulse measurement is primarily based on a single-chip microcontroller unit (MCU) that receives the signal of a fingertip pulse and converts it into electrical signals using an infrared sensor. The signals are amplified and filtered by the proposed circuit and software. The pulse meter displays the measured value on a liquid crystal display ( LCD) 1602 screen. The result with the prototype pulse meter with the proposed circuit design and software shows an accuracy of 98.9-102.5% and a relative standard deviation of 0.82-0.90%. The proposed design provides the basis for developing further improved pulse meters that are appropriate for mobile devices.
引用
收藏
页码:4077 / 4085
页数:9
相关论文
共 50 条
  • [21] PORTABLE SUSCEPTIBILITY SURVEY METER
    SAHASRAB.PW
    PURE AND APPLIED GEOPHYSICS, 1971, 87 (04) : 161 - &
  • [22] A PORTABLE SKY LUMINANCE METER
    MURDOCH, JB
    LEVIN, RE
    ENERGY AND BUILDINGS, 1984, 6 (03) : 241 - 246
  • [23] Portable laser exposure meter
    不详
    OPTICS AND LASER TECHNOLOGY, 1999, 31 (01): : IV - IV
  • [24] A PORTABLE OXYGEN ELECTRODE METER
    HOOTS, KC
    PACKER, L
    AMERICAN BIOLOGY TEACHER, 1969, 31 (09): : 575 - &
  • [25] PORTABLE WATER VELOCITY METER
    EDINGTON, JM
    MOLYNEUX, L
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1960, 37 (12): : 455 - 457
  • [26] A PORTABLE TD-METER
    BERTRAND, G
    CAROSSI, JC
    FOUILHE, C
    SIGUIER, J
    VIEUXMAI.C
    BULLETIN D INFORMATIONS SCIENTIFIQUES ET TECHNIQUES, 1969, (138S): : 27 - &
  • [27] A PORTABLE MOUTH PRESSURE METER
    SMITH, PEM
    ROYALL, RA
    ANAESTHESIA, 1992, 47 (02) : 144 - 145
  • [28] Portable Chlorophyll Content Meter
    不详
    AGRO FOOD INDUSTRY HI-TECH, 2001, 12 (05): : 71 - 71
  • [29] Portable pulse oximetry - A simple and useful outpatient screen for lung disease
    Lloyd, M.
    Ho, T.
    Burton, S.
    RHEUMATOLOGY, 2007, 46 : I140 - I140
  • [30] Design of Multi Nozzles for a Portable Air Flow Meter using Numerical Simulation
    Oh, Sang Taek
    Park, Jong Jun
    Kim, Young Il
    Kim, Sean Hay
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 1, 2019, 125 : 298 - 306