Low-dose hypersensitivity in nucleus-irradiated V79 cells studied with synchrotron X-ray microbeam

被引:31
|
作者
Maeda, Munetoshi [1 ]
Usami, Noriko [1 ]
Kobayashi, Katsumi [1 ]
机构
[1] High Energy Accelerator Res Org, Inst Mat Struct Sci, Photon Factory, Tsukuba, Ibaraki 3050801, Japan
关键词
X-ray microbeam; cell survival; low-dose radiation; low-dose hypersensitivity;
D O I
10.1269/jrr.07093
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aims at elucidating the cellular responses induced by energy deposition in the cell nucleus or cytoplasm in the low-dose (< 1 Gy) region. We compared the survival fraction of V79 cells irradiated with X-ray microbeams of different sizes. Entire cells or cell nuclei were targeted with 5.35 keV monochromatic X-ray microbeams using a synchrotron radiation (SR) X-ray microbeam irradiation apparatus. Using a threshold of 30 cells/colony after 60 h of incubation, conditions that had been proven to give results equivalent to those of the conventional method, we determined the survival fraction of the microbeam-irradiated cells. When cell nuclei were irradiated with 10 x 10 pm 2 X-ray beams, the survival fraction was almost the same as that obtained with 50 x 50 mu m(2) beams except in the low-dose region. In the low-dose region irradiated with 10 x 10 mu m(2) beams, hyper-radiosensitivity (HRS) was clearly observed in the nucleus-irradiated cells, and the survival curve exhibited a minimum of about 60% at 0.5 Gy. This may be the most distinct HRS reported thus far when an asynchronous population is used. Difference in observed HRS phenomena is solely due to the irradiated part in the cell. These results suggest that energy deposition in the cytoplasm might suppress the HRS.
引用
收藏
页码:171 / 180
页数:10
相关论文
共 50 条
  • [31] EVALUATION OF A NEW LOW-DOSE DIGITAL X-RAY SYSTEM
    MARTINEZDAVALOS, A
    SPELLER, RD
    HORROCKS, JA
    MILLER, DJ
    BARU, SE
    KHABAKHPASHEV, AG
    PONOMAREV, OA
    SHEKHTMAN, LI
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (10): : 1419 - 1432
  • [32] Simulation of image degradation in low-dose x-ray mammography
    Wanninger, F
    Treiber, O
    Panzer, W
    Regulla, D
    Winkler, G
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1102 - 1102
  • [33] Nonlinear sinogram smoothing for low-dose X-ray CT
    Li, TF
    Li, X
    Wang, J
    Wen, JH
    Lu, HB
    Hsieh, J
    Liang, ZR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2505 - 2513
  • [34] LOW-DOSE X-RAY TREATMENT OF 44 HEMANGIOMAS OF LID
    BAMBERG, M
    SCHERER, E
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1978, 103 (33) : 1293 - 1297
  • [35] Treatment of cutaneous hemangiomas with low-dose soft x-ray
    常宝珠
    顾恒
    钱恒林
    李光中
    柳朋生
    汪惠珍
    曹宁校
    张荣林
    Chinese Medical Journal, 1997, (11)
  • [36] PORTABLE LOW-DOSE X-RAY IMAGING-SYSTEM
    YIN, LI
    SELTZER, SM
    TROMBKA, JI
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1977, 27 (NOV): : 167 - 168
  • [37] Treatment of cutaneous hemangiomas with low-dose soft x-ray
    Chang, BZ
    Gu, H
    Qian, HL
    Li, GZ
    Liu, PS
    Wang, HZ
    Cao, NX
    Zhang, RL
    CHINESE MEDICAL JOURNAL, 1997, 110 (11) : 893 - 894
  • [38] LOW-DOSE X-RAY EFFECTS ON PRECLEAVAGE MAMMALIAN ZYGOTE
    RUGH, R
    WOHLFROM.M
    VARMA, A
    RADIATION RESEARCH, 1969, 37 (02) : 401 - &
  • [39] Treatment of cutaneous hemangiomas with low-dose soft x-ray
    常宝珠
    顾恒
    钱恒林
    李光中
    柳朋生
    汪惠珍
    曹宁校
    张荣林
    中华医学杂志(英文版), 1997, (11) : 77 - 78
  • [40] Characterization of an avalanche detector for low-dose X-ray imaging
    Wronski, M.
    Reznik, A.
    Rowlands, J.
    Zhao, W.
    MEDICAL PHYSICS, 2009, 36 (09) : 4321 - 4321