Preparation of Electrochemical Sensor Based on Magnetic Graphene Nanocomposite for Determination of Dopamine

被引:6
|
作者
Wang, Weiwei [1 ]
Wei, Fan [1 ]
Han, Baiping [1 ]
机构
[1] Xuzhou Univ Technol, Sch Phys & New Energy, Xuzhou 221018, Jiangsu, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Dopamine; Magnetic graphene nanocomposite; Fe-Ni bimetal oxides; Graphene oxide; Amperometry; GLASSY-CARBON ELECTRODE; ASCORBIC-ACID; URIC-ACID; AMPEROMETRIC DETERMINATION; VOLTAMMETRIC DETERMINATION; FUNCTIONALIZED GRAPHENE; SENSITIVE DETECTION; THIN-FILMS; OXIDE; NANOPARTICLES;
D O I
10.20964/2022.02.33
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This work was focused on the preparation of an electrochemical sensor based on magnetic graphene nanocomposite for the determination of dopamine (DA) in human plasma samples. The electrodeposition method was used for the synthesis of magnetic graphene nanocomposite based on Fe-Ni bimetal oxides (Fe2O3-NiO) and graphene oxide (GO) on a glassy carbon electrode (GCE). Fe2O3-NiO@GO/GCE using XRD and SEM confirmed the simultaneous electrodeposition of Fe-Ni bimetal oxide nanoparticles in the spherical-shaped 2D wrinkled stack of ultra-thin GO nanosheets without any aggregation. Electrochemical analyses using DPV and amperometry techniques showed the good electrocatalytic activity, stability, and selectivity of Fe2O3-NiO@GO/GCE towards the oxidation of DA with rapid electron transfer and mass transport. Furthermore, the sensitivity and detection limit of magnetic graphene nanocomposite sensors were obtained at 0.16812 mu A/mu M and 0.005 mu M, respectively, which were compared with the other reported DA electrochemical sensors and the results indicated comparable detection limit values and broader linear range of Fe2O3NiO@GO/GCE for the determination of DA. The practical capability of Fe2O3-NiO@GO/GCE for the determination of DA was investigated in prepared real samples of human blood serum of six patients aged 55 to 70 years who were administered an intropin injection. Results showed that there was good agreement between the amperometry and ELISA measurements, and the obtained RSD ranged from 3.08% to 4.36% illustrated the acceptable accuracy of both techniques, especially Fe2O3NiO@GO/GCE as a reliable and accurate electrochemical DA sensor in clinical and pharmaceutical analyses.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A Novel Electrochemical Sensor Based on Conductive Cu3(HITP)2/electrochemical Reduced Graphene Oxide Nanocomposite for Simultaneous Determination of Dopamine and Acetaminophen
    Li, Shanshan
    Dai, Hongxia
    Chen, Hui
    Zhang, Jian
    Shi, Xiaoning
    Zhang, Haobo
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (12):
  • [22] An electrochemical sensor for simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan based on MWNTs bridged mesocellular graphene foam nanocomposite
    Li, Huixiang
    Wang, Yi
    Ye, Daixin
    Luo, Juan
    Su, Biquan
    Zhang, Song
    Kong, Jilie
    TALANTA, 2014, 127 : 255 - 261
  • [23] Gold-dendrimer Nanocomposite based Electrochemical Sensor for Dopamine
    Sipuka, Dimpo S.
    Arotiba, Omotayo A.
    Sebokolodi, Tsholofelo, I
    Tsekeli, Tebogo R.
    Nkosi, Duduzile
    ELECTROANALYSIS, 2023, 35 (03)
  • [24] Graphene-Au nanoparticles nanocomposite film for selective electrochemical determination of dopamine
    Li, Juan
    Yang, Juan
    Yang, Zhanjun
    Li, Yongfang
    Yu, Suhua
    Xu, Qin
    Hu, Xiaoya
    ANALYTICAL METHODS, 2012, 4 (06) : 1725 - 1728
  • [25] An Electrochemical Sensor with Graphene-Graphene Oxide Nanocomposite and Ammonium Molybdate for Phosphate Determination
    Chang, Yaw-Jen
    Chen, Yi-Chien
    Chien, You-Chivan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (12):
  • [26] An Electrochemical Sensor with Graphene-Graphene Oxide Nanocomposite and Ammonium Molybdate for Phosphate Determination
    Chang, Yaw-Jen
    Chen, Yi-Chien
    Chien, You-Chiua
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (01):
  • [27] Determination of ascorbic acid, dopamine, and uric acid by a novel electrochemical sensor based on pristine graphene
    Qi, Shaopeng
    Zhao, Bo
    Tang, Heqing
    Jiang, Xiaoqing
    ELECTROCHIMICA ACTA, 2015, 161 : 395 - 402
  • [28] A Sensitive Phenol Electrochemical Sensor Based on Magnetic Oxide/Amino-Functional Graphene Nanocomposite
    Meng, Zuchao
    Li, Mao
    Li, Chengxi
    Liu, Xiang
    Lei, Zigang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (03): : 3126 - 3137
  • [29] A new electrochemical sensor based on an Au-Pd/reduced graphene oxide nanocomposite for determination of Parathion
    Jahromi, Mojtaba. N.
    Tayadon, Fariba
    Bagheri, Hasan
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (10) : 1101 - 1117
  • [30] A new electrochemical sensor based on a nitrogen-doped graphene/CuCo2O4 nanocomposite for simultaneous determination of dopamine, melatonin and tryptophan
    Tadayon, F.
    Sepehri, Z.
    RSC ADVANCES, 2015, 5 (80): : 65560 - 65568