EKG-gated Low-dose Chest CT Imaging

被引:0
|
作者
Hsieh, Jiang
Londt, John
Dutta, Sandeep
Okerlund, Darin
机构
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Majority of the CT cardiac scans is performed with EKG-gated low-pitch helical. Many of the procedures are accompanied by the examination of the lungs for pulmonary emboli or atypical masses. Because of the EKG-based gating and the half-scan algorithm used in the cardiac reconstruction, the lung portion of the image exhibits low spatial resolution and high level of noise. In this paper, we present a new reconstruction algorithm that takes full advantage of the low-pitch helical and the x-ray tube current modulation to significantly improve the spatial resolution and noise performance.
引用
收藏
页码:1666 / 1669
页数:4
相关论文
共 50 条
  • [21] Low-Dose Chest CT for the Diagnosis of COVID-19
    Schulze-Hagen, Maximilian
    Huebel, Christian
    Meier-Schroers, Michael
    Yueksel, Can
    Sander, Anton
    Saehn, Marwin
    Kleines, Michael
    Isfort, Peter
    Cornelissen, Christian
    Lemmen, Sebastian
    Marx, Nikolaus
    Dreher, Michael
    Brokmann, Joerg
    Kopp, Andreas
    Kuhl, Christiane
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2020, 117 (22-23): : 389 - +
  • [22] Automated aorta segmentation in low-dose chest CT images
    Yiting Xie
    Jennifer Padgett
    Alberto M. Biancardi
    Anthony P. Reeves
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 211 - 219
  • [23] Biological Effects of Low-Dose Chest CT on Chromosomal DNA
    Sakane, Hiroaki
    Ishida, Mari
    Shi, Lin
    Fukumoto, Wataru
    Sakai, Chiemi
    Miyata, Yoshihiro
    Ishida, Takafumi
    Akita, Tomoyuki
    Okada, Morihito
    Awai, Kazuo
    Tashiro, Satoshi
    RADIOLOGY, 2020, 295 (02) : 439 - 445
  • [24] Segmentation of the sternum from low-dose chest CT images
    Liu, Shuang
    Xie, Yiting
    Reeves, Anthony P.
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [25] Automated aorta segmentation in low-dose chest CT images
    Xie, Yiting
    Padgett, Jennifer
    Biancardi, Alberto M.
    Reeves, Anthony P.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (02) : 211 - 219
  • [26] Local noise estimation in low-dose chest CT images
    Padgett, J.
    Biancardi, A. M.
    Henschke, C. I.
    Yankelevitz, D.
    Reeves, A. P.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (02) : 221 - 229
  • [27] Accuracy of low-dose chest CT in intensive care patients
    Börjesson J.
    Latifi A.
    Friman O.
    Beckman M.O.
    Oldner A.
    Labruto F.
    Emergency Radiology, 2011, 18 (1) : 17 - 21
  • [28] Segmentation of Individual Ribs from Low-dose Chest CT
    Lee, Jaesung
    Reeves, Anthony P.
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
  • [29] A prospective evaluation of low-dose spiral chest CT in children
    Rigsby, CK
    Benya, EC
    Saker, MC
    Lin, PP
    Shore, RM
    RADIOLOGY, 2001, 221 : 574 - 574
  • [30] Local noise estimation in low-dose chest CT images
    J. Padgett
    A. M. Biancardi
    C. I. Henschke
    D. Yankelevitz
    A. P. Reeves
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 221 - 229