Lightning Protection System on Overhead Distribution Line Using Multi Chamber Arrester

被引:0
|
作者
Perdana, Erlangga [1 ]
Hidayat, Syarif [1 ]
Zoro, Reynaldo [1 ]
机构
[1] Bandung Inst Technol, Lightning Res Ctr, Sch Elect Engn & Informat, Bandung, Indonesia
关键词
Multi Chamber Arrester; 20 kV overhead line; line fault of feeder Ruko;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
New innovation on arrester technology has been made by appearance of Multi Chamber Arrester (MCA). This kind of arrester has basic principle similar to previous technology which use air gap and air pressure in chamber as its technology. MCA has a function to protect overhead line from lightning. For instance, 20 kV medium voltage overhead line. Field testing has been set up to get analysis on MCA. Field testing has been done on 20 kV medium voltage overhead line of feeder Ruko of PLN Serpong. After a certain period of installation, line fault pattern of feeder Ruko is then captured to get the analysis. The analysis is used to get conclusions whether MCA is appropriate for lightning protection system on 20 kV overhead lines.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 50 条
  • [1] Influence of the lightning arrester position on protection of the 220KV Overhead transmission line
    Boumous, Samira
    Boumous, Zouhir
    Latreche, Samia
    Nouri, Hamou
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (05): : 13 - 17
  • [2] Multi-Chamber Arrester Study at Tropical Area for 20 kV Lines Lightning Protection System
    Zoro, Reynaldo
    Leo, Tulus
    [J]. 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS 2015, 2015, : 197 - 201
  • [3] Mathematical Simulation of Processes in Discharge Chamber of Multi-Chamber System for Lightning Protection at Overhead Power Lines
    Frolov, Vladimir
    Ivanov, Dmitriy
    Murashov, Iurii
    Sivaev, Alexandr
    [J]. PROCEEDINGS OF THE 2016 IEEE NORTH WEST RUSSIA SECTION YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING CONFERENCE (ELCONRUSNW), 2016, : 562 - 565
  • [4] Research on lightning protection of distribution network overhead insulated line
    Liu, Pai
    Shen, Zhen
    Xu, Wei
    Dong, Yijie
    Li, Yi
    Yang, Yong
    [J]. 2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [5] Lightning arrester protection of distribution transformers - Revisited
    Darveniza, Mat
    [J]. Journal of Electrical and Electronics Engineering, Australia, 2002, 22 (02): : 141 - 146
  • [6] Revision of lightning protection map for overhead contact line system
    Nakayama, Masahiro
    Furuyama, Yukio
    Aoyagi, Haruki
    Katou, Hiroshi
    Nakamura, Takehiko
    Iino, Yuuki
    Yamazaki, Takeshi
    Hayashiya, Hitoshi
    Tsuchizawa, Dan
    [J]. 2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [7] Technical and economical optimisation of overhead power distribution line lightning protection
    Katic, NA
    Savic, MS
    [J]. IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1998, 145 (03) : 239 - 244
  • [8] Lightning Protection With a Differentiated Arrester Configuration for Distribution Networks Using a Multi-Objective Optimization Procedure
    Cao, Jsinxin
    Du, Yaping
    Ding, Yuxuan
    Lyu, Jiahua
    Qi, Ruihan
    Chen, Mingli
    Andreotti, Amedeo
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (03) : 2149 - 2159
  • [9] Lightning overvoltage analysis according to interval of arrester and overhead grounding wire in DC distribution system
    [J]. Lee, J.-B. (ipower@wku.ac.kr), 1600, Korean Institute of Electrical Engineers (62):
  • [10] Overhead Lines Lightning Protection by Multi-Chamber Arresters and Insulator-Arresters
    Podporkin, Georgij V.
    Enkin, Evgeniy Yu
    Kalakutsky, Evgeniy S.
    Pilshikov, Vladimir E.
    Sivaev, Alexander D.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (01) : 234 - 241