Preliminary experimental study on the performance of CO2 capture prototype based on temperature swing adsorption (TSA)

被引:22
|
作者
Wu, Kailong [1 ,2 ]
Deng, Shuai [1 ,2 ]
Li, Shuangjun [1 ,2 ]
Zhao, Ruikai [1 ,2 ]
Yuan, Xiangzhou [3 ]
Zhao, Li [1 ]
机构
[1] Tianjin Univ, Minist Educ China, Key Lab Efficient Utilizat Low & Medium Grade Ene, Tianjin 300350, Peoples R China
[2] Int Cooperat Res Ctr Carbon Capture Ultra Low Ene, Tianjin 300350, Peoples R China
[3] Korea Univ, Dept Chem & Biol Engn, 145 Anam Ro, Seoul 02831, South Korea
来源
关键词
Temperature swing adsorption; Carbon capture; Experiment; Prototype-scale; Double-column fixed bed; Performance analysis; FLUE-GAS; PSA PROCESS; SEPARATION; 13X; SIMULATION; CO2/N-2; VACUUM; CONSUMPTION; TECHNOLOGY; PARAMETERS;
D O I
10.1016/j.ccst.2022.100035
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Capturing CO2 from the post-combustion flue gas through temperature swing adsorption (TSA) has been considered as an effective solution to reduce carbon emissions. However, in the fixed bed field, the vast majority of the existing experimental studies are bench-scale. In this study, a fixed bed double-column TSA prototype with treatment capacity of 2.4 m(3)/h flue gas is designed and developed. The influence from parameters, such as desorption duration, adsorption temperature, desorption temperature, CO2 concentration, heat recovery duration and vacuum duration, are analyzed, to the prototype performance, based on the preliminary experiment data. The performance indicators include purity, recovery ratio, productivity, specific energy consumption, coefficient of performance of CO2 capture and exergy efficiency. The prototype performance in single- and double-column modes are compared as well. The results of double-column mode show that decrease of adsorption temperature (from 293 K to 278 K), increase of desorption temperature (from 353 K to 373 K) and CO2 concentration (from 13% to 19%) lead to an improvement of the prototype performance, the maximum purity, recovery and productivity are 98.13%, 81.30% and 25.22 kg/(ton.h), respectively. The maximum coefficient of performance of CO2 capture and exergy efficiency are 2.46 and 17.67%, respectively. Extending the desorption time is conducive to the improvement of the prototype performance, however, a long operation time would be meaningless to improve performance. With the addition of heat recovery, exergy efficiency increases from 12.30% to 12.89%. At the same time, the productivity of double-column is 2.24 times higher than that of single-column.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Amines immobilized on a solid support for postcombustion CO2 capture - A preliminary analysis of the performance in a VSA or TSA process based on the adsorption isotherms and kinetic data
    Pirngruber, Gerhard D.
    Cassiano-Gaspar, Stefania
    Louret, Sylvain
    Chaumonnot, Alexandra
    Delfort, Bruno
    GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01): : 1335 - 1342
  • [32] CO2 Capture by Temperature Swing Adsorption: Use of Hot CO2-Rich Gas for Regeneration
    Ntiamoah, Augustine
    Ling, Jianghua
    Xiao, Penny
    Webley, Paul A.
    Zhai, Yuchun
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (03) : 703 - 713
  • [33] Computational simulation study of the influence of faujasite Si/Al ratio on CO2 capture by temperature swing adsorption
    Prats, Hector
    Bahamon, Daniel
    Gimenez, Xavier
    Gamallo, Pablo
    Sayos, Ramon
    JOURNAL OF CO2 UTILIZATION, 2017, 21 : 261 - 269
  • [34] Optimization of pressure swing adsorption and fractionated vacuum pressure swing adsorption processes for CO2 capture
    Ko, D
    Siriwardane, R
    Biegler, LT
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (21) : 8084 - 8094
  • [35] Temperature Swing Adsorption for Postcombustion CO2 Capture: Single- and Multicolumn Experiments and Simulations
    Marx, Dorian
    Joss, Lisa
    Hefti, Max
    Mazzotti, Marco
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (05) : 1401 - 1412
  • [36] Rational design of temperature swing adsorption cycles for post-combustion CO2 capture
    Joss, Lisa
    Gazzani, Matteo
    Mazzotti, Marco
    CHEMICAL ENGINEERING SCIENCE, 2017, 158 : 381 - 394
  • [37] The effect of nitrogen adsorption on vacuum swing adsorption based post-combustion CO2 capture
    Rajagopalan, Ashwin Kumar
    Rajendran, Arvind
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 78 : 437 - 447
  • [38] The CO2 Capture System with a Swing Temperature Moving Bed
    Kozak-Jagiela, Ewa
    Rerak, Monika
    Zima, Wieslaw
    Cebula, Artur
    Gradziel, Slawomir
    Mondino, Giorgia
    Blom, Richard
    Nord, Lars O.
    Skjervold, Vidar T.
    ACTA MECHANICA ET AUTOMATICA, 2024, 18 (01) : 93 - 100
  • [39] Understanding the Mechanism of Electrochemical CO2 Capture by Supercapacitive Swing Adsorption
    Mapstone, Grace
    Kamsma, Tim M.
    Xu, Zhen
    Jones, Penelope K.
    Lee, Alpha A.
    Temprano, Israel
    Lee, James
    De Volder, Michael F. L.
    Forse, Alexander C.
    ACS NANO, 2025, 19 (04) : 4242 - 4250
  • [40] Investigation of sorbents for warm CO2 capture by pressure swing adsorption
    Liu, Zan
    Green, William H.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245