Preliminary experimental study on the performance of CO2 capture prototype based on temperature swing adsorption (TSA)

被引:22
|
作者
Wu, Kailong [1 ,2 ]
Deng, Shuai [1 ,2 ]
Li, Shuangjun [1 ,2 ]
Zhao, Ruikai [1 ,2 ]
Yuan, Xiangzhou [3 ]
Zhao, Li [1 ]
机构
[1] Tianjin Univ, Minist Educ China, Key Lab Efficient Utilizat Low & Medium Grade Ene, Tianjin 300350, Peoples R China
[2] Int Cooperat Res Ctr Carbon Capture Ultra Low Ene, Tianjin 300350, Peoples R China
[3] Korea Univ, Dept Chem & Biol Engn, 145 Anam Ro, Seoul 02831, South Korea
来源
关键词
Temperature swing adsorption; Carbon capture; Experiment; Prototype-scale; Double-column fixed bed; Performance analysis; FLUE-GAS; PSA PROCESS; SEPARATION; 13X; SIMULATION; CO2/N-2; VACUUM; CONSUMPTION; TECHNOLOGY; PARAMETERS;
D O I
10.1016/j.ccst.2022.100035
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Capturing CO2 from the post-combustion flue gas through temperature swing adsorption (TSA) has been considered as an effective solution to reduce carbon emissions. However, in the fixed bed field, the vast majority of the existing experimental studies are bench-scale. In this study, a fixed bed double-column TSA prototype with treatment capacity of 2.4 m(3)/h flue gas is designed and developed. The influence from parameters, such as desorption duration, adsorption temperature, desorption temperature, CO2 concentration, heat recovery duration and vacuum duration, are analyzed, to the prototype performance, based on the preliminary experiment data. The performance indicators include purity, recovery ratio, productivity, specific energy consumption, coefficient of performance of CO2 capture and exergy efficiency. The prototype performance in single- and double-column modes are compared as well. The results of double-column mode show that decrease of adsorption temperature (from 293 K to 278 K), increase of desorption temperature (from 353 K to 373 K) and CO2 concentration (from 13% to 19%) lead to an improvement of the prototype performance, the maximum purity, recovery and productivity are 98.13%, 81.30% and 25.22 kg/(ton.h), respectively. The maximum coefficient of performance of CO2 capture and exergy efficiency are 2.46 and 17.67%, respectively. Extending the desorption time is conducive to the improvement of the prototype performance, however, a long operation time would be meaningless to improve performance. With the addition of heat recovery, exergy efficiency increases from 12.30% to 12.89%. At the same time, the productivity of double-column is 2.24 times higher than that of single-column.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Numerical analysis on CO2 capture process of temperature swing adsorption (TSA): Optimization of reactor geometry
    Lian, Yahui
    Deng, Shuai
    Li, Shuangjun
    Guo, Zhihao
    Zhao, Li
    Yuan, Xiangzhou
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2019, 85 : 187 - 198
  • [2] Experimental investigation on energy-efficiency performance of temperature swing adsorption system for CO2 capture
    Liu B.
    Deng S.
    Li S.
    Zhao L.
    Du Z.
    Chen L.
    Huagong Xuebao/CIESC Journal, 2020, 71 : 382 - 390
  • [3] Experimental investigation on separation and energy-efficiency performance of temperature swing adsorption system for CO2 capture
    Liu, Bowen
    Lian, Yahui
    Li, Shuangjun
    Deng, Shuai
    Zhao, Li
    Chen, Bing
    Wang, Dahai
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 227
  • [4] A comparative study on CO2 capture performance of vacuum-pressure swing adsorption and pressure-temperature swing adsorption based on carbon pump cycle
    Zhao, Ruikai
    Zhao, Li
    Deng, Shuai
    Song, Chunfeng
    He, Junnan
    Shao, Yawei
    Li, Shuangjun
    ENERGY, 2017, 137 : 495 - 509
  • [5] A numerical analysis on energy-efficiency performance of temperature swing adsorption for CO2 capture
    He, Junnan
    Deng, Shuai
    Zhao, Li
    Zhao, Ruikai
    Li, Shuangjun
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 3200 - 3207
  • [6] CO2 Capture by Temperature Swing Adsorption: Working Capacity As Affected by Temperature and CO2 Partial Pressure
    Raganati, Federica
    Chirone, Riccardo
    Ammendola, Paola
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (08) : 3593 - 3605
  • [7] Experimental study of the adsorber performance in a multi-stage fluidized bed system for continuous CO2 capture by means of temperature swing adsorption
    Dietrich, Florian
    Schoeny, Gerhard
    Fuchs, Johannes
    Hofbauer, Hermann
    FUEL PROCESSING TECHNOLOGY, 2018, 173 : 103 - 111
  • [8] Experimental Investigation of Sorbent for Warm CO2 Capture by Pressure Swing Adsorption
    Liu, Zan
    Green, William H.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (28) : 9665 - 9673
  • [9] A fast methodology to rank adsorbents for CO2 capture with temperature swing adsorption
    Gutierrez-Ortega, A.
    Nomen, R.
    Sempere, J.
    Parra, J. B.
    Montes-Moran, M. A.
    Gonzalez-Olmos, R.
    CHEMICAL ENGINEERING JOURNAL, 2022, 435
  • [10] Performance analysis of temperature swing adsorption for CO2 capture using thermodynamic properties of adsorbed phase
    Zhao, Ruikai
    Deng, Shuai
    Zhao, Li
    Li, Shuangjun
    Zhang, Yue
    Liu, Bowen
    APPLIED THERMAL ENGINEERING, 2017, 123 : 205 - 215