Totally implantable active middle ear implant: Hearing and safety results in a large series

被引:9
|
作者
Shohet, Jack A. [1 ]
Gende, Deanna M. [1 ]
Tanita, Cheryl S. [1 ]
机构
[1] Shohet Ear Associates, 446 Old Newport Blvd, Newport Beach, CA 92663 USA
来源
LARYNGOSCOPE | 2018年 / 128卷 / 12期
关键词
Middle ear implants; totally implantable hearing aid; sensorineural hearing loss; active middle ear hearing device; SYSTEM; SURGERY; TRIAL; PALSY;
D O I
10.1002/lary.27246
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives To evaluate hearing performance and safety measures in a large group of totally implantable active middle ear implant (AMEI) wearers. Methods Retrospective case review of 172 ears (166 patients) with sensorineural hearing loss undergoing implantation of a totally implantable AMEI. Pure-tone air and bone thresholds, pure-tone average, speech reception threshold (SRT), and word recognition scores (WRS) at phonetically balanced maximum and at 50 dB (WRS50) were assessed at baseline unaided, with a hearing aid (baseline aided [BLA]), with the implant at activation, and for best implant postoperative measurement. Adverse events were reviewed. Results Mean length of follow-up was 35.7 months. Compared to unaided, the implant provided significant gain at all frequencies through 6 kHz. Amount of gain was significantly better with the implant than BLA at 1,500 and 2,000 Hz (P <= .001). Implant SRT was also significantly improved compared to BLA (29.9 dB vs. 38.5 dB, P <= .001). At a 50-dB presentation level, WRS was significantly better with the implant than BLA (65.6% vs. 45.5%, P <= .001). Bone conduction thresholds were not affected by the implant. The most common adverse event was taste disturbance, which occurred in 39.1%. In subjects with preimplant tinnitus, 56.1% experienced resolution of their tinnitus. Revision surgery was required in 15.7%, and 4% were ultimately explanted. Conclusion The implant provided significant hearing benefit compared to unaided and to the subjects' own hearing aids in most test categories, with minimal adverse events. Many subjects experienced complete resolution of their tinnitus after implantation. Level of Evidence 4 Laryngoscope, 128:2872-2878, 2018
引用
收藏
页码:2872 / 2878
页数:7
相关论文
共 50 条
  • [41] A Systematic Review of the Safety and Effectiveness of Fully Implantable Middle Ear Hearing Devices: The Carina and Esteem Systems
    Klein, Kristin
    Nardelli, Alexa
    Stafinski, Tania
    OTOLOGY & NEUROTOLOGY, 2012, 33 (06) : 916 - 921
  • [42] Implantable Bone Conduction and Active Middle Ear Devices
    Pirlich, Markus
    Dietz, Andreas
    Meuret, Sylvia
    Hofer, Mathias
    LARYNGO-RHINO-OTOLOGIE, 2017, 96 (02) : 120 - 128
  • [43] Sheep as a Large Animal Model for Middle and Inner Ear Implantable Hearing Devices: A Feasibility Study in Cadavers
    Schnabl, Johannes
    Glueckert, Rudolf
    Feuchtner, Gudrun
    Recheis, Wolfgang
    Potrusil, Thomas
    Kuhn, Volker
    Wolf-Magele, Astrid
    Riechelmann, Herbert
    Sprinzl, Georg M.
    OTOLOGY & NEUROTOLOGY, 2012, 33 (03) : 481 - 489
  • [44] Design of a transcutaneous infrared remote control for the totally implantable middle ear system
    Yoon, YH
    Jung, ES
    Song, RS
    Lee, SH
    Cho, JH
    IEICE TRANSACTIONS ON ELECTRONICS, 2005, E88C (09): : 1896 - 1899
  • [45] A MICROMINIATURE ELECTROMAGNETIC MIDDLE-EAR IMPLANT HEARING DEVICE
    AFFANE, W
    BIRCH, TS
    SENSORS AND ACTUATORS A-PHYSICAL, 1995, 47 (1-3) : 584 - 587
  • [46] Application of an active middle ear implant in congenital middle ear malformations: A contemporary review
    da Silva, Vagner Antonio Rodrigues
    Pauna, Henrique Furlan
    Guimaraes, Guilherme Correa
    Lavinsky, Joel
    Linder, Thomas E.
    Castilho, Arthur Menino
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2025, 91 (03)
  • [47] Application of Implantable Hearing Aids and Bone Conduction Implant System in patients with bilateral congenital deformation of the external and middle ear
    Lin, Junfeng
    Chen, Suijun
    Zhang, Huasong
    Xiong, Hao
    Zhang, Zhigang
    Liang, Maojin
    Zhang, Xueyuan
    Ye, Haiwen
    Zheng, Yiqing
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2019, 119 : 89 - 95
  • [48] Development of a fully-implantable middle ear hearing device in Korea
    Lee, Jyung Hyun
    Seong, Ki Woong
    Jung, Eui Sung
    Lim, Hyung Gyu
    Kim, Min Woo
    Lee, Jang Woo
    Kim, Dong Wook
    Lee, Myoung Won
    Park, Il Yong
    Lee, Kyu Yup
    Lee, Sang Heun
    Cho, Jin Ho
    HEARING RESEARCH, 2010, 263 (1-2) : 247 - 247
  • [49] Testing a method for quantifying the output of implantable middle ear hearing devices
    Rosowski, J. J.
    Chien, W.
    Ravicz, M. E.
    Merchant, S. N.
    AUDIOLOGY AND NEURO-OTOLOGY, 2007, 12 (04) : 265 - 276
  • [50] Design of a magnetic coupling type implantable middle ear hearing aid
    Song, BS
    Jung, YS
    Yoon, YH
    Bae, SK
    Kim, MN
    Cho, JH
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 3166 - 3169