Design and adaptability of photovoltaic air conditioning system based on office buildings

被引:24
|
作者
Chen, Yingya [1 ,2 ]
Liu, Yanfeng [1 ]
Liu, Jingrui [1 ,2 ]
Luo, Xi [1 ,2 ]
Wang, Dengjia [1 ,2 ]
Wang, Yingying [1 ,2 ]
Liu, Jiaping [1 ,2 ]
机构
[1] Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, 13 Yanta Rd, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, 13 Yanta Rd, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Photovoltaic air conditioning; Office buildings; Design of parameters; Energy saving; Emission reduction; ENERGY-CONSUMPTION; SOLAR-RADIATION; HOT SUMMER; PERFORMANCE; EFFICIENCY; BENEFITS; IMPACTS;
D O I
10.1016/j.solener.2020.03.055
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Photovoltaic (PV) air conditioning (AC) is an effective way to solve the problems of energy consumption of office buildings. In this study, a set of parameters were designed for PV AC, including PV capacity, AC parameter, and inverter parameter. Then, the parameters were applied to a 20-m(2) office building, and a PV AC system test platform was built. The test lasted for one year; the corresponding data including typical daily data and annual data were collected and analyzed. The results show that the PV AC system quickly decreases or increases the room temperature by similar to 9.5% and 17% in 1 h of cooling and heating periods, respectively, thus maintaining the room temperature within the set temperature range of +/- 0.9 degrees C. The data also show that by proper design of parameters, a PV AC system can satisfy the electricity demand of AC. In the cooling period, heating period, and annual operation conditions, the PV system provided 114%, 73%, and 188% of the energy for the AC system, respectively. Next, economic calculations show that PV AC is suitable for office buildings. The local payback period is only 7.5 years; both the energy saving and emission reduction are significant.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [31] A renewable energy based air conditioning system for buildings with high comfort requirements
    Schuck, M.
    Speerforck, A.
    Niemann, P.
    Grabe, J.
    Schmitz, G.
    BAUINGENIEUR, 2016, 91 : 288 - 296
  • [32] A New Through-Wall Air Conditioning System with Improved Performance for High-Rise Office Buildings
    Tsukami, Shiro
    Kubo, Hirotaka
    Icinose, Masayuki
    Kato, Takaya
    SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2019 TOKYO (SBE19TOKYO) - BUILT ENVIRONMENT IN AN ERA OF CLIMATE CHANGE: HOW CAN CITIES AND BUILDINGS ADAPT?, 2019, 294
  • [33] Study on energy saving possibility of digital variable multiple air conditioning system in three office buildings in Shanghai
    Zhang, Dongliang
    Zhang, Xu
    Cai, Ning
    ENERGY AND BUILDINGS, 2014, 75 : 23 - 28
  • [34] Modeling of an air-conditioning system in smart buildings
    Khabthani, Abir
    Chaabane, Leila
    2015 7th International Conference on Modelling, Identification and Control (ICMIC), 2014, : 34 - 37
  • [35] Effects of outdoor air conditions on hybrid air conditioning based on task/ambient strategy with natural and mechanical ventilation in office buildings
    Chang, HJ
    Kato, S
    Chikamoto, T
    BUILDING AND ENVIRONMENT, 2004, 39 (02) : 153 - 164
  • [36] Design of a renewable energy based air-conditioning system
    Prasartkaew, Boonrit
    Kumar, S.
    ENERGY AND BUILDINGS, 2014, 68 : 156 - 164
  • [37] Home energy management system for smart buildings with inverter-based air conditioning system
    Nezhad, Ali Esmaeel
    Rahimnejad, Abolfazl
    Gadsden, S. Andrew
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 133
  • [38] Design of the multizone air conditioning system and layout of office towers in Beijing East Gate Plaza
    Yang, Weicheng
    Nuantong Kongtiao/HV & AC, 2000, 30 (02): : 54 - 57
  • [39] Simulation Analysis of System Partition in Office Building Air Conditioning System
    Yu, Yu
    Li, Hui
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3686 - 3691
  • [40] Energy audit and air-conditioning system renovation analysis on office buildings using air-source heat pump in Shanghai
    Han, Xing
    Chen, Jianbo
    Huang, Chen
    Weng, Wenbing
    Wang, Lihui
    Niu, Runping
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2014, 35 (04): : 376 - 392