Comparison of Direct and Indirect Laser Ablation of Metallized Paper for Inexpensive Paper-Based Sensors

被引:25
|
作者
Rahimi, Rahim [1 ,2 ,3 ]
Ochoa, Manuel [1 ,2 ]
Ziaie, Babak [1 ,2 ]
机构
[1] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Birck Nanotechnol Ctr, W Lafayette, IN 47907 USA
[3] Purdue Univ, Sch Mat Engn, W Lafayette, IN 47907 USA
关键词
laser processing; paper-based sensor; low-cost sensors; metallized paper; humidity sensor; MICROFLUIDICS; FABRICATION; MECHANISM; ELECTRODE; NANOTUBE; DEVICES; PH;
D O I
10.1021/acsami.8b09598
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this work, we present a systematic study of laser processing of metallized papers (MPs) as a simple and scalable alternative to conventional photolithography-based processes and printing technologies. Two laser-processing methods are examined in terms of selectivity for the removal of the conductive aluminum film (25 nm) of an MP substrate; these processes, namely direct and indirect laser ablation (DLA and ILA), operate at wavelengths of 1.06 mu m (neodymium-doped yttrium aluminum garnet) and 10.6 mu m (CO2), respectively. The required threshold energy for each laser processing method was systematically measured using electrical, optical, and mechanical characterization techniques. The results of these investigations show that the removal of the metal coating using ILA is only achieved through partial etching of the paper substrate. The ILA process shows a narrow effective set of laser settings capable of removing the metal film while not completely burning through the paper substrate. By contrast, DLA shows a more defined and selective removal of the aluminum layer without damaging the mechanical and natural fibular structure of the paper substrate. Finally, as a proof of concept, interdigitated capacitive moisture sensors were fabricated by means of DLA and ILA onto the MP substrate, and their performance was assessed in the humidity range of 2-85%. The humidity sensitivity results show that the DLA sensors have a superior humidity sensing performance compared to the ILA sensors. The observed behavior is attributed to the higher water molecule absorption and induced capillary condensation within the intact cellulose network resulting from the DLA process (compared to the damaged one from the ILA process). The DLA process of MP should enable scalable production of low-cost, paper-based physical and chemical sensing systems for potential use in point-of-care diagnostics and food packaging.
引用
收藏
页码:36332 / 36341
页数:10
相关论文
共 50 条
  • [11] The Effect of Paper on the Detection Limit of Paper-Based Potentiometric Chloride Sensors
    Herrero, Eliza J.
    Troudt, Blair K.
    Buhlmann, Philippe
    ANALYTICAL CHEMISTRY, 2022, 94 (43) : 14898 - 14905
  • [12] Progress in patterned paper sizing for fabrication of paper-based microfluidic sensors
    Xu Li
    Junfei Tian
    Wei Shen
    Cellulose, 2010, 17 : 649 - 659
  • [13] Progress in patterned paper sizing for fabrication of paper-based microfluidic sensors
    Li, Xu
    Tian, Junfei
    Shen, Wei
    CELLULOSE, 2010, 17 (03) : 649 - 659
  • [14] Paper-Based Sensors: Emerging Themes and Applications
    Singh, Amrita Tribhuwan
    Lantigua, Darlin
    Meka, Akhil
    Taing, Shainlee
    Pandher, Manjot
    Camci-Unal, Gulden
    SENSORS, 2018, 18 (09)
  • [15] Fabrication of paper-based microfluidic sensors by printing
    Li, Xu
    Tian, Junfei
    Garnier, Gil
    Shen, Wei
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 76 (02) : 564 - 570
  • [16] Green paper-based piezoelectronics for sensors and actuators
    Lemaire, E.
    Moser, R.
    Borsa, C. J.
    Briand, D.
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 244 : 285 - 291
  • [17] Engineering Paper-Based Sensors for Zika Virus
    Meagher, Robert J.
    Negrete, Oscar A.
    Van Rompay, Koen K.
    TRENDS IN MOLECULAR MEDICINE, 2016, 22 (07) : 529 - 530
  • [18] PAPER-BASED PIEZORESISTIVE MEMS FORCE SENSORS
    Liu, X. Y.
    O'Brien, M.
    Mwangi, M.
    Li, X. J.
    Whitesides, G. M.
    2011 IEEE 24TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2011, : 133 - 136
  • [19] Laser direct-writing to enable filtration in paper-based devices
    Galanis, Panagiotis P.
    He, Peijun J. W.
    Katis, Ioannis N.
    Thomas, Michael R.
    Xianyu, Yunlei
    Stevens, Molly M.
    Eason, Robert W.
    Sones, Collin L.
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS XVII, 2019, 10875
  • [20] Direct Electrode Modification of Paper-based Microfluidic Sensors through Electrodeposition and Electropolymerization
    Ghanbari, Mohammad Hossein
    Etzold, Bastian J. M.
    2023 IEEE SENSORS, 2023,