Magnetic resonance imaging of the brain in patients with cardiac pace makers.: In-vitro- and in-vivo-evaluation at 1.5 Tesla

被引:31
|
作者
Schmiedel, A
Hackenbroch, M
Yang, A
Nähle, CP
Skowasch, D
Meyer, C
Schimpf, R
Schild, H
Sommer, T
机构
[1] Univ Bonn, Radiol Klin, D-53105 Bonn, Germany
[2] Univ Bonn, Med Klin & Poliklin 2, D-53105 Bonn, Germany
关键词
magnetic resonance imaging; cardiac pacemakers; metal implants;
D O I
10.1055/s-2005-858110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In-vitro and In-vivo evaluation of feasibility and safety of MRI of the brain at 1.5 T in patients with implanted pacemakers (PM). Materials and Methods: 24 PM models and 45 PM electrodes were tested In-vitro with respect to translational forces, heating of PM leads, behaviour of reed switch (activated vs. deactivated) and function at a 1.5 T MRI-system (actively shielded, maximum field gradient: 30mT/m; rise time: 150 T/ m/s). Based on these results, 63 MRI examinations in 45 patients with implanted PM were performed. Prior to MRI the PM were re-programmed in an asynchronous mode. The maximum SAR of MRI-sequences was limited to 1.2 W/kg. Continuous monitoring of ECG and pulse oximetry was performed during MRI. PM inquiry was performed prior to MRI, immediately after MRI and to assess long-term damages - three months after the MRI exams, including determination of stimulation thresholds to assess potential thermal myocardial injuries at the lead tips. Results: Translational forces (F-max <= 560 mN) and temperature increase (Delta T-max <= 2.98 degrees C) were in a range which does not represent a safety concern from a biophysical point of view. No changes to the programmed parameters of the PM or damage of PM components were observed neither In-vitro (n = 0/24) nor In-vivo (n = 01 63). Despite the strong magnetic field, the reed switch remained deactivated in 54 % (13/24) of the cases during In-vitro simulated MRI exams of the brain. All patient studies (n = 63/63) could be completed without any complications. Atrial and ventricular stimulation thresholds (expressed as pulse duration at 2-fold rheobase) did not change significantly immediately post-MRI nor in the 3 months follow-up (pre-MRI: 0.17 ms +/- 0.13 ms, post-MRI: 0.18 ms +/- 0.14 ms, 3 months follow-up: 0.17 ms +/- 0.12 ms). Conclusion: MRI of the brain at 1.5 Tesla can be safely performed in carefully selected clinical circumstances when appropriate strategies are used (re-programming the PM to an asynchronous mode, continuous monitoring of ECG and pulse oximetry, limiting the SAR value of the MRI sequences, cardiological stand-by). Based on these studies, implanted PM should not longer be regarded as an absolute contrainclication for MRI at 1.5 T.
引用
收藏
页码:731 / 744
页数:14
相关论文
共 50 条
  • [41] Clinical Utility of Magnetic Resonance Imaging of Patients with Permanent Pacemakers and Implantable-Cardioverter Defibrillators at 1.5 Tesla
    Nazarian, Semen
    Hansford, Rozann
    Roguin, Ariel
    Zviman, Menekhem M.
    Lardo, Albert C.
    Calkins, Hugh
    Berger, Ronald D.
    Bluemke, David A.
    Halperin, Henry R.
    CIRCULATION, 2008, 118 (18) : S777 - S778
  • [42] DETERMINING THE RISKS OF MAGNETIC RESONANCE IMAGING AT 1.5 TESLA FOR PATIENTS WITH PACEMAKERS AND IMPLANTABLE CARDIOVERTER DEFIBRILLATORS: THE MAGNASAFE REGISTRY
    Russo, Robert J.
    Costa, Heather
    Kabra, Ashish
    Doud, Debra
    Uretsky, Seth
    Wolff, Steven
    Martin, Edward
    Machado, Christian
    Higgins, Steven
    Tominaga, Gail
    Florin, Todd
    Bloomgarden, Daniel
    Birgersdotter-Green, Ulrika
    Ponce, George
    Schaerf, Raymond
    Lampert, Rachel
    Shah, Dipan
    Arshad, Aysha
    Anderson, Jeffrey
    Tonkin, Allison
    Rivard, Andrew
    Fyke, Frazier
    Biederman, Robert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E810 - E810
  • [43] Determining the Risks of Magnetic Resonance Imaging at 1.5 Tesla for Patients With Pacemakers and Implantable Cardioverter Defibrillators (the MagnaSafe Registry)
    Russo, Robert
    Costa, Heather
    Kabra, Ashish
    Uretsky, Seth
    Wolff, Steven D.
    Martin, Edward T.
    Higgins, Steven
    Tominaga, Gail
    Machado, Christian
    Florin, Todd
    Bloomgarden, Daniel C.
    Birgersdotter-Green, Ulrika
    Ponce, George
    Schaerf, Raymond
    Lampert, Rachel
    Shah, Dipan
    Arshad, Aysha
    Tonkin, Allison
    Anderson, Jeffrey
    Rivard, Andrew
    Wolfe, Douglas A.
    Biederman, Robert
    Rubenstein, Jason
    Tomassoni, Gery
    Boyle, Noel G.
    CIRCULATION, 2013, 128 (22)
  • [44] Determining the Risks of Magnetic Resonance Imaging at 1.5 Tesla for Patients with Pacemakers and Implantable Cardioverter Defibrillators (The MagnaSafe Registry)
    Russo, Robert J.
    Costal, Heather S.
    Doud, Debra
    Uretsky, Seth
    Wolff, Steven D.
    Martin, Edward T.
    Higgins, Steven
    Tominaga, Gail
    Machado, Christian
    Florin, Todd
    Bloomgarden, Daniel C.
    Birgersdotter-Green, Ulrika
    Ponce, George
    Schaerf, Raymond
    Lampert, Rachel
    Chilson, Donald
    Shah, Dipan J.
    Arshad, Aysha
    Tonkin, Alison
    Anderson, Jeffrey
    CIRCULATION, 2012, 126 (21)
  • [45] Influence of Magnetic Field Strength on Magnetic Resonance Imaging Radiomics Features in Brain Imaging, an In Vitro and In Vivo Study
    Ammari, Samy
    Pitre-Champagnat, Stephanie
    Dercle, Laurent
    Chouzenoux, Emilie
    Moalla, Salma
    Reuze, Sylvain
    Talbot, Hugues
    Mokoyoko, Tite
    Hadchiti, Joya
    Diffetocq, Sebastien
    Volk, Andreas
    El Haik, Mickeal
    Lakiss, Sara
    Balleyguier, Corinne
    Lassau, Nathalie
    Bidault, Francois
    FRONTIERS IN ONCOLOGY, 2021, 10
  • [46] Assessment of Nicotinamide Adenine Dinucleotide in Human Tissues by In Vivo Phosphorus-31 Magnetic Resonance Spectroscopic Imaging at 1.5 Tesla
    Arias-Mendoza, Fernando
    Nath, Kavindra
    Xu, He N.
    Gupta, Pradeep K.
    Li, Lin Z.
    OXYGEN TRANSPORT TO TISSUE XLIII, 2022, 1395 : 323 - 328
  • [47] Magnetic resonance imaging at 1.5T with immunospecific contrast agent in vitro and in vivo in a xenotransplant model
    Baio, G.
    Fabbi, M.
    de Totero, D.
    Ferrini, S.
    Cilli, M.
    Derchi, L. E.
    Neumaier, C. E.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (06) : 313 - 320
  • [48] In vivo evaluation of brain iron in Alzheimer disease using magnetic resonance imaging
    Bartzokis, G
    Sultzer, D
    Cummings, J
    Holt, LE
    Hance, DB
    Henderson, VW
    Mintz, J
    ARCHIVES OF GENERAL PSYCHIATRY, 2000, 57 (01) : 47 - 53
  • [49] Cardiovascular magnetic resonance imaging produces highly reproducible rodent cardiac volumetric and functional data using a 1.5 Tesla scanner
    Gayathri Kumarasinghe
    Chung Yao Yu
    Michael Chang
    Kirsten Moffat
    Rene M Botnar
    James Otton
    Cameron Holloway
    Jane McCrohon
    Peter Macdonald
    Andrew Jabbour
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [50] In vitro demonstration using 19F magnetic resonance to augment molecular imaging with paramagnetic perfluorocarbon nanoparticles at 1.5 Tesla
    Caruthers, SD
    Neubauer, AM
    Hockett, FD
    Lamerichs, R
    Winter, PM
    Scott, MJ
    Gaffney, PJ
    Wickline, SA
    Lanza, GM
    INVESTIGATIVE RADIOLOGY, 2006, 41 (03) : 305 - 312