Magnetic resonance imaging of the brain in patients with cardiac pace makers.: In-vitro- and in-vivo-evaluation at 1.5 Tesla

被引:31
|
作者
Schmiedel, A
Hackenbroch, M
Yang, A
Nähle, CP
Skowasch, D
Meyer, C
Schimpf, R
Schild, H
Sommer, T
机构
[1] Univ Bonn, Radiol Klin, D-53105 Bonn, Germany
[2] Univ Bonn, Med Klin & Poliklin 2, D-53105 Bonn, Germany
关键词
magnetic resonance imaging; cardiac pacemakers; metal implants;
D O I
10.1055/s-2005-858110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In-vitro and In-vivo evaluation of feasibility and safety of MRI of the brain at 1.5 T in patients with implanted pacemakers (PM). Materials and Methods: 24 PM models and 45 PM electrodes were tested In-vitro with respect to translational forces, heating of PM leads, behaviour of reed switch (activated vs. deactivated) and function at a 1.5 T MRI-system (actively shielded, maximum field gradient: 30mT/m; rise time: 150 T/ m/s). Based on these results, 63 MRI examinations in 45 patients with implanted PM were performed. Prior to MRI the PM were re-programmed in an asynchronous mode. The maximum SAR of MRI-sequences was limited to 1.2 W/kg. Continuous monitoring of ECG and pulse oximetry was performed during MRI. PM inquiry was performed prior to MRI, immediately after MRI and to assess long-term damages - three months after the MRI exams, including determination of stimulation thresholds to assess potential thermal myocardial injuries at the lead tips. Results: Translational forces (F-max <= 560 mN) and temperature increase (Delta T-max <= 2.98 degrees C) were in a range which does not represent a safety concern from a biophysical point of view. No changes to the programmed parameters of the PM or damage of PM components were observed neither In-vitro (n = 0/24) nor In-vivo (n = 01 63). Despite the strong magnetic field, the reed switch remained deactivated in 54 % (13/24) of the cases during In-vitro simulated MRI exams of the brain. All patient studies (n = 63/63) could be completed without any complications. Atrial and ventricular stimulation thresholds (expressed as pulse duration at 2-fold rheobase) did not change significantly immediately post-MRI nor in the 3 months follow-up (pre-MRI: 0.17 ms +/- 0.13 ms, post-MRI: 0.18 ms +/- 0.14 ms, 3 months follow-up: 0.17 ms +/- 0.12 ms). Conclusion: MRI of the brain at 1.5 Tesla can be safely performed in carefully selected clinical circumstances when appropriate strategies are used (re-programming the PM to an asynchronous mode, continuous monitoring of ECG and pulse oximetry, limiting the SAR value of the MRI sequences, cardiological stand-by). Based on these studies, implanted PM should not longer be regarded as an absolute contrainclication for MRI at 1.5 T.
引用
收藏
页码:731 / 744
页数:14
相关论文
共 50 条
  • [1] Magnetic resonance imaging in patients with cardiac pacemakers: In vitro and in vivo evaluation at 0.5 Tesla.
    Sommer, T
    Lauck, G
    Schimpf, R
    von Smekal, A
    Wolke, S
    Block, W
    Gieseke, J
    Schneider, C
    Funke, HD
    Schild, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (01): : 36 - 43
  • [2] Cardiac pacemakers and implantable cardioverter defibrillators:: In vitro magnetic resonance imaging evaluation at 1.5-Tesla
    Shellock, Frank G.
    Fischer, Laura
    Fieno, David S.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (01) : 21 - 31
  • [3] Artefacts in 1.5 Tesla and 3 Tesla cardiac magnetic resonance imaging in patients with leadless cardiac pacemakers
    Kiblboeck, D.
    Reiter, C.
    Kammler, J.
    Schmit, P.
    Blessberger, H.
    Kellermair, J.
    Lukas, T.
    Kypta, A.
    Fellner, F.
    Steinwender, C.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 113 - 113
  • [4] Artefacts in 1.5 Tesla and 3 Tesla cardiovascular magnetic resonance imaging in patients with leadless cardiac pacemakers
    Daniel Kiblboeck
    Christian Reiter
    Juergen Kammler
    Pierre Schmit
    Hermann Blessberger
    Joerg Kellermair
    Franz Fellner
    Clemens Steinwender
    Journal of Cardiovascular Magnetic Resonance, 20
  • [5] Artefacts in 1.5 Tesla and 3 Tesla cardiovascular magnetic resonance imaging in patients with leadless cardiac pacemakers
    Kiblboeck, Daniel
    Reiter, Christian
    Kammler, Juergen
    Schmit, Pierre
    Blessberger, Hermann
    Kellermair, Joerg
    Fellner, Franz
    Steinwender, Clemens
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [6] Magnetic Resonance Imaging at 1.5 Tesla in Patients with Cardiac Pacemakers: A prospective study in 388 patients
    Becker, Alexander
    Muehling, Olaf
    Gleixner, Julia
    Morhard, Dominik
    Wakili, Reza
    Brueckmann, Hartmut
    Knez, Andreas
    CIRCULATION, 2010, 122 (21)
  • [7] Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla
    Rezai, AR
    Finelli, D
    Nyenhuis, JA
    Hrdlicka, G
    Tkach, J
    Sharan, A
    Rugieri, P
    Stypulkowski, PH
    Shellock, FG
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (03) : 241 - 250
  • [8] Implantable cardiac defibrillator interactions with magnetic resonance imaging at 1.5 Tesla
    Coman, JA
    Martin, ET
    Sandler, DA
    Thomas, JR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 138A - 138A
  • [9] Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla
    Martin, ET
    Coman, JA
    Shellock, FG
    Pulling, CC
    Fair, R
    Jenkins, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) : 1315 - 1324
  • [10] Preliminary findings on the safety of 1.5 and 3 Tesla magnetic resonance imaging in cardiac pacemaker patients
    van Dijk, Vincent F.
    Delnoy, Peter Paul H. M.
    Smit, Jaap Jan J.
    Misier, R. Anand Ramdat
    Elvan, Arif
    van Es, H. Wouter
    Rensing, Benno J. W. M.
    Raciti, Giovanni
    Boersma, Lucas V. A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (07) : 806 - 810