Test-Retest Reliability of Volume and Local Tissue Water Measurements in Lower Limbs of Healthy Women and Men

被引:14
|
作者
Jonsson, Charlotta [1 ,2 ]
Bjurberg, Maria [2 ,3 ]
Brogardh, Christina [1 ]
Johansson, Karin [1 ]
机构
[1] Lund Univ, Dept Hlth Sci, Lund, Sweden
[2] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Lasarettsgatan 23A, S-22185 Lund, Sweden
[3] Lund Univ, Dept Clin Sci, Lund, Sweden
关键词
lower extremity; anthropometry; instrumentation; reproducibility of results; healthy volunteers; DIELECTRIC-CONSTANT; LYMPHEDEMA; AGREEMENT; VALIDATION;
D O I
10.1089/lrb.2019.0044
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Measurements of lower limb (LL) volume and local tissue water by tissue dielectric constant (TDC) are common in lymphedema management. Knowledge of normal variability in health subjects is important and can serve as a base for early lymphedema diagnosis but is currently lacking. The aim of this study was to evaluate test-retest reliability of LL volume and TDC values in healthy women and men. Methods and Results: Thirty-three women and 28 men were measured twice, 2 weeks apart. Volume was calculated from circumferential measurements every 4 cm and TDC in 14 points. Test-retest reliability was evaluated using intraclass correlation coefficient (ICC), changes in the mean, standard error of measurement in percentage (SEM%), and smallest real difference in percentage (SRD%). For volume, reliability was high (ICC 0.99) and measurement errors were low in both women and men (SEM%: 1.1%-1.3%; SRD%: 3.1%-3.6%). For TDC, reliability was fair to excellent in women (ICC 0.63-0.93) and poor to excellent in men (ICC 0.21-0.89). Measurement errors were acceptable in all points in women (SEM%: 3.9%-10.2%; SRD% 10.8%-28.2%), but only in 11 points in men (SEM%: 3.9%-14.5%; SRD%: 10.9%-40.1%). The points close to bone and tendons in men had lower reliability and higher measurement errors. Conclusion: Measurements of LL volume and TDC are reliable in healthy women and men; both methods can be recommended. However, TDC points close to bone and tendons in men should be used with caution.
引用
收藏
页码:261 / 269
页数:9
相关论文
共 50 条
  • [21] Test-Retest Reliability of the Acoustic Stapedial Reflex Test in Healthy Neonates
    Mazlan, Rafidah
    Kei, Joseph
    Hickson, Louise
    EAR AND HEARING, 2009, 30 (03): : 295 - 301
  • [22] A multicenter study of the test-retest reliability of the lower extremity functional test
    Tabor, MA
    Davies, GJ
    Kernozek, TW
    Negrete, RJ
    Hudson, V
    JOURNAL OF SPORT REHABILITATION, 2002, 11 (03) : 190 - 201
  • [23] Test-retest reliability of vestibular autorotation testing in healthy subjects
    Guyot, JP
    Psillas, G
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1997, 117 (06) : 704 - 707
  • [24] Test-Retest and Interrater Reliability of the Functional Lower Extremity Evaluation
    Haitz, Karyn
    Shultz, Rebecca
    Hodgins, Melissa
    Matheson, Gordon O.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2014, 44 (12): : 947 - 954
  • [25] Test-retest reliability of lower extremity functional instability measures
    Birmingham, TB
    CLINICAL JOURNAL OF SPORT MEDICINE, 2000, 10 (04): : 264 - 268
  • [26] Test-retest reliability of Patrick's hip range of motion test in healthy college-aged men
    Ross, MD
    Nordeen, MH
    Barido, M
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2003, 17 (01) : 156 - 161
  • [27] Test-retest reliability in isokinetic muscle strength measurements of the shoulder
    van Meeteren, J
    Roebroeck, ME
    Stam, HJ
    JOURNAL OF REHABILITATION MEDICINE, 2002, 34 (02) : 91 - 95
  • [28] Test-retest Reliability of GPS derived Measurements in Patients with Claudication
    Gernigon, M.
    Fouasson-Chailloux, A.
    Colas-Ribas, C.
    Noury-Desvaux, B.
    Le Faucheur, A.
    Abraham, P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (05) : 623 - 629
  • [29] Test-retest reliability of posture measurements in adolescents with idiopathic scoliosis
    Heitz, Pierre-Henri
    Aubin-Fournier, Jean-Francois
    Parent, Eric
    Fortin, Carole
    SPINE JOURNAL, 2018, 18 (12): : 2247 - 2258
  • [30] Test-Retest Reliability Of Rectus-Femoris Ultrasound Measurements
    Heredia-Vintimilla, D. J.
    Maddipati, V.
    Khan, N.
    Aguilera, J.
    Collins, E. G.
    McBurney, C.
    Fares, S.
    Jubran, A.
    Tobin, M. J.
    Laghi, F.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191