Differential Measurement for Cavity Ring-Down Spectroscopy with Dynamic Allan Variance

被引:1
|
作者
Mo, Zeqiang [1 ,2 ,3 ]
Yu, Jin [1 ,2 ]
Wang, Jinduo [1 ,2 ]
He, Jianguo [1 ,2 ,3 ]
Dai, Shoujun [1 ,2 ]
Liu, Yang [1 ,3 ]
机构
[1] Chinese Acad Sci, Aerosp Informat Res Inst, Beijing 100094, Peoples R China
[2] Univ Chinese Acad Sci, Sch Optoelect, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Key Lab Computat Opt Imaging Technol, Beijing 100094, Peoples R China
关键词
SPECTROMETER; ABSORPTION; METHANE;
D O I
10.1155/2020/8398063
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The method of dynamic Allan variance (DAVAR) is used to analyze the time-varying characteristics of a nonstationary signal and is thus incorporated to evaluate the random error in the cavity ring-down spectroscopy (CRDS) experiments. With the numerical simulation of the influence of instabilities of sudden, slow, or periodic changes on the measurement accuracy in the ring-down process, DAVAR is proved to be an effective way to evaluate random error characteristics in an interfering environment. In order to minimize influences of time-varying noises in CRDS, a practical differential measurement method is proposed, in which wavelength modulation is applied to detect the ring-down times at the absorption peak and the nonabsorption peak in a time-division manner. The validity of the differential measurement is proved with its ability to compensate the influence of the environment changes and improves the accuracy from 0.181 ppm to 0.00914 ppm. The differential measurement method can be used to correct the time-varying error in real time and is helpful to improve the environmental adaptability of the CRDS instrument.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Towards Supercontinuum Cavity Ring-Down Spectroscopy
    Stelmaszczyk, K.
    Fechner, M.
    Rohwetter, P.
    Queisser, M.
    Czyzewski, A.
    Stacewicz, T.
    Woeste, L.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2009, 94 (03): : 369 - 373
  • [22] Cavity ring-down spectroscopy with diode array
    Nikolaev, Igor V.
    Ochkin, Vladimir N.
    Spiridonov, Maxim V.
    Tskhai, Sergei N.
    15TH SYMPOSIUM ON HIGH-RESOLUTION MOLECULAR SPECTROSCOPY, 2006, 6580
  • [23] Measuring pressure with cavity ring-down spectroscopy
    van Zee, RD
    Looney, JP
    Hodges, JT
    ADVANCED SENSORS AND MONITORS FOR PROCESS INDUSTRIES AND THE ENVIRONMENT, 1999, 3535 : 46 - 56
  • [24] Cavity-locked ring-down spectroscopy
    Paldus, BA
    Harb, CC
    Spence, TG
    Wilke, B
    Xie, J
    Harris, JS
    Zare, RN
    JOURNAL OF APPLIED PHYSICS, 1998, 83 (08) : 3991 - 3997
  • [25] Aligning an optical cavity: with reference to cavity ring-down spectroscopy
    Telfah, Hamzeh
    Paul, Anam C.
    Liu, Jinjun
    APPLIED OPTICS, 2020, 59 (30) : 9464 - 9468
  • [26] Measurement of Nitrogen Pentoxide in Nocturnal Atmospheric Based on Cavity Ring-Down Spectroscopy
    Wang D.
    Hu R.
    Xie P.
    Liu X.
    Li Z.
    Liu H.
    Huang X.
    Wang D.
    Zhao G.
    Hu, Renzhi (rzhu@aiofm.ac.cn), 2017, Chinese Optical Society (37):
  • [27] Diode laser cavity ring-down spectroscopy for atmospheric NO2 measurement
    Hu R.
    Wang D.
    Xie P.
    Chen H.
    Ling L.
    Guangxue Xuebao/Acta Optica Sinica, 2016, 36 (02):
  • [28] Integrating cavity ring-down spectroscopy (ICRDS) and the direct measurement of absorption coefficients
    Fry, Edward S.
    Mason, John D.
    PHYSICA SCRIPTA, 2016, 91 (04)
  • [29] Application of pulse cavity ring-down spectroscopy technique for aerosol extinction measurement
    Guo, Jie
    Xiang, Jindong
    Wang, Liming
    Shao, Jie
    Zheng, Qingying
    Zhou, Zhen
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS VI, 2014, 9274
  • [30] Detection of Sulfur Dioxide by Cavity Ring-Down Spectroscopy
    Medina, David S.
    Liu, Yingdi
    Wang, Liming
    Zhang, Jingsong