Differential Measurement for Cavity Ring-Down Spectroscopy with Dynamic Allan Variance

被引:1
|
作者
Mo, Zeqiang [1 ,2 ,3 ]
Yu, Jin [1 ,2 ]
Wang, Jinduo [1 ,2 ]
He, Jianguo [1 ,2 ,3 ]
Dai, Shoujun [1 ,2 ]
Liu, Yang [1 ,3 ]
机构
[1] Chinese Acad Sci, Aerosp Informat Res Inst, Beijing 100094, Peoples R China
[2] Univ Chinese Acad Sci, Sch Optoelect, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Key Lab Computat Opt Imaging Technol, Beijing 100094, Peoples R China
关键词
SPECTROMETER; ABSORPTION; METHANE;
D O I
10.1155/2020/8398063
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The method of dynamic Allan variance (DAVAR) is used to analyze the time-varying characteristics of a nonstationary signal and is thus incorporated to evaluate the random error in the cavity ring-down spectroscopy (CRDS) experiments. With the numerical simulation of the influence of instabilities of sudden, slow, or periodic changes on the measurement accuracy in the ring-down process, DAVAR is proved to be an effective way to evaluate random error characteristics in an interfering environment. In order to minimize influences of time-varying noises in CRDS, a practical differential measurement method is proposed, in which wavelength modulation is applied to detect the ring-down times at the absorption peak and the nonabsorption peak in a time-division manner. The validity of the differential measurement is proved with its ability to compensate the influence of the environment changes and improves the accuracy from 0.181 ppm to 0.00914 ppm. The differential measurement method can be used to correct the time-varying error in real time and is helpful to improve the environmental adaptability of the CRDS instrument.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Differential cavity ring-down spectroscopy
    Courtois, Jeromie
    Bielska, Katarzyna
    Hodges, Joseph T.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2013, 30 (06) : 1486 - 1495
  • [3] METHYL RADICAL MEASUREMENT BY CAVITY RING-DOWN SPECTROSCOPY
    ZALICKI, P
    MA, Y
    ZARE, RN
    WAHL, EH
    DADAMIO, JR
    OWANO, TG
    KRUGER, CH
    CHEMICAL PHYSICS LETTERS, 1995, 234 (4-6) : 269 - 274
  • [4] Measurement of Atmospheric Ozone by Cavity Ring-down Spectroscopy
    Washenfelder, R. A.
    Wagner, N. L.
    Dube, W. P.
    Brown, S. S.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (07) : 2938 - 2944
  • [5] Cavity ring-down spectroscopy
    Zare, RN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 215 : U83 - U83
  • [6] Cavity ring-down spectroscopy
    Wheeler, MD
    Newman, SM
    Orr-Ewing, AJ
    Ashfold, MNR
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1998, 94 (03): : 337 - 351
  • [7] Frequency-domain measurement of cavity ring-down spectroscopy
    Gao, XM
    Sasada, H
    Anzai, K
    Yoshida, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (03): : 1452 - 1456
  • [8] The theory of hydroxyl radical measurement by cavity ring-down spectroscopy
    Nie Jingsong
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: LASER SENSING AND IMAGING AND BIOLOGICAL AND MEDICAL APPLICATIONS OF PHOTONICS SENSING AND IMAGING, 2011, 8192
  • [9] Fast and Accurate Extraction of Ring-Down Time in Cavity Ring-Down Spectroscopy
    Wang Dan
    Hu Ren-zhi
    Xie Pin-hua
    Qin Min
    Ling Liu-yi
    Duan Jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (10) : 2845 - 2850
  • [10] Study on precise measurement of high reflectivity by cavity ring-down spectroscopy
    Ren, G
    Cai, BW
    Zhang, B
    Xiong, SM
    Huang, W
    Gao, LF
    2ND INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PTS 1 AND 2, 2006, 6150