Hydrologic and Pollutant Removal Performance of Media Layers in Bioretention

被引:14
|
作者
Yang, Feikai [1 ,2 ]
Fu, Dafang [1 ,2 ]
Liu, Shuang [1 ,2 ]
Zevenbergen, Chris [3 ]
Singh, Rajendra Prasad [1 ,2 ]
机构
[1] Southeast Univ, Sch Civil Engn, Nanjing 210096, Peoples R China
[2] Southeast Univ Monash Univ Joint Res Ctr Future C, Nanjing 210096, Peoples R China
[3] IHE Delft, Inst Water Educ, Delft 2611 DA, Netherlands
关键词
bioretention; filter layers; filter media; stormwater; peak flow; pollutants; URBAN PARTICLE CAPTURE;
D O I
10.3390/w12030921
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The current study was aimed to investigate the filler layer structure in modified bioretention systems. Three different structural layers in bioretention were proposed to evaluate their hydrologic performance and pollutant removal efficiency under different rainfall intensities. These layers were as follows: all three layers (filter, transition, and drainage layers), without transition layer, and without drainage layer. Synthetic stormwater was used for experimental purpose in current work. Results revealed that compared with "all three layers", runoff control rate of "without transition layer" and "without drainage layer" was reduced by 0 to 7.4%, 0 to 10.1%, and outflow start time was advanced by 6 to 8 min and 1.5 to 4.5 min, respectively. Moreover, CODcr (chemical oxygen demand), NH4+-N (ammonium nitrogen), TN (total nitrogen) and TP (total phosphorus) removal rates were 86.0%, 85.4%, 71.8%, and 68.0%, respectively. Particle size distribution of the fillers revealed that during operation, particle moved downward were mainly within 0.16-0.63 mm size. Findings showed that transition and drainage layer played an important role in runoff control, and total height of the filler layer should not be less than 800 mm. Filter layer effectively reduce runoff pollution but the thickness of the filter layer should not be less than 500 mm. Whereas, transition layer has the function of preventing the filler loss of the filter layer; therefore, proper measures must be taken into consideration during structural optimization.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Hydraulic and pollutant removal performance of fine media stormwater filtration systems
    Hatt, Belinda E.
    Fletcher, Tim D.
    Deletic, Ana
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (07) : 2535 - 2541
  • [32] Pollutant removal and peak flow mitigation by a bioretention cell in urban Charlotte, NC
    Hunt, W. F.
    Smith, J. T.
    Jadlocki, S. J.
    Hathaway, J. M.
    Eubanks, P. R.
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2008, 134 (05): : 403 - 408
  • [33] Impact of wood-derived biochar on the hydrologic performance of bioretention media: Effects on aggregation, root growth, and water retention
    Akpinar, Derya
    Tian, Jing
    Shepherd, Elizabeth
    Imhoff, Paul T.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2023, 339
  • [34] Global analysis of sensitivity of bioretention cell design elements to hydrologic performance
    Sun, Yan-Wei
    Wei, Xiao-Mei
    Pomeroy, Christine A.
    WATER SCIENCE AND ENGINEERING, 2011, 4 (03) : 246 - 257
  • [35] Analysis of the Hydrologic Performance in a Lined Bioretention Basin and Implications for Monitoring and Design
    Adhikari, Bishwodeep
    Mcphillips, Lauren
    JOURNAL OF SUSTAINABLE WATER IN THE BUILT ENVIRONMENT, 2025, 11 (01):
  • [36] Field Assessment of the Hydrologic Mitigation Performance of Three Aging Bioretention Cells
    Johnson, Jeffrey P.
    Hunt, William F.
    JOURNAL OF SUSTAINABLE WATER IN THE BUILT ENVIRONMENT, 2020, 6 (04)
  • [37] Pollutant removal in an experimental bioretention cell situated in a northern Chinese sponge City
    Shi, Chunyan
    Feng, Xia
    Sun, Weining
    Qiu, Hong
    Liu, Gen
    Li, Siwen
    Xie, Jing
    Wang, Pengxuan
    Lin, Yingzi
    Wei, Xindong
    Xu, Tongyu
    Gao, Weijun
    WATER SCIENCE AND TECHNOLOGY, 2024, 89 (08) : 2164 - 2176
  • [38] Hydrologic response of engineered media in living roofs and bioretention to large rainfalls: experiments and modeling
    Liu, Ruifen
    Fassman-Beck, Elizabeth
    HYDROLOGICAL PROCESSES, 2017, 31 (03) : 556 - 572
  • [39] A Modeling Framework for Bioretention Analysis: Assessing the Hydrologic Performance under System Uncertainty
    Gomes Jr, Marcus Nobrega
    Giacomoni, Marcio Hofheinz
    de Macedo, Marina Batalini
    do Lago, Cesar Ambrogi Ferreira
    Brasil, Jose Artur Teixeira
    de Oliveira, Thalita Raquel Pereira
    Mendiondo, Eduardo Mario
    JOURNAL OF HYDROLOGIC ENGINEERING, 2023, 28 (09)
  • [40] Experimental Investigation on Hydrologic Performance of LID with Rainfall-Watershed-Bioretention System
    Gulbaz, Sezar
    Kazezyilmaz-Alhan, Cevza Melek
    JOURNAL OF HYDROLOGIC ENGINEERING, 2017, 22 (01)