Qualitative and quantitative strain and shear wave elastography paradigm in differentiation of breast lesions

被引:3
|
作者
Shehata, Roaa M. A. [1 ]
El-Sharkawy, Mostafa A. M. [2 ]
Mahmoud, Omar M. [1 ]
Kamel, Hosam M. [1 ]
机构
[1] Assiut Univ, Assiut Univ Hosp, South Egypt Canc Inst, Dept Diagnost Radiol, Asyut 71515, Egypt
[2] Assiut Univ, Fac Med, Asyut, Egypt
来源
关键词
Elastography; Strain ratio; Elasticity score; Shear wave; Breast; Benign; Malignant; DIAGNOSIS; BENIGN; MASSES; CLASSIFICATION; ULTRASOUND; RATIO;
D O I
10.1186/s43055-022-00697-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Breast cancer is the most common life-threatening cancer in women worldwide. A high number of women are going through biopsy procedures for characterization of breast masses every day and yet 75% of the pathological results prove these masses to be benign. Ultrasound (US) elastography is a non-invasive technique that measures tissue stiffness. It is convenient for differentiating benign from malignant breast tumors. Our study aims to evaluate the role of qualitative ultrasound elastography scoring (ES), quantitative mass strain ratio (SR), and shear wave elasticity ratio (SWER) in differentiation between benign and malignant breast lesions. Results: Among 51 female patients with 77 histopathologically proved breast lesions, 57 breast masses were malignant and 20 were benign. All patients were examined by B-mode ultrasound then strain and shear wave elastographic examinations using ultrasound machine (Logiq E9, GE Medical Systems) with 8.5-12 MHz high-frequency probes. Our study showed that ES best cut-off point >3 with sensitivity, specificity, PPV, NPP, accuracy was 94.7%, 85%, 94.7%, 85%, 90.9%, respectively, and AUC= 0.926 at P< 0.001, mass SR the best cut-off point >4.6 with sensitivity, specificity, PPV, NPP, accuracy was 96.5%, 80%, 93.2%, 88.9%, 92.2%, respectively, and AUC= 0.860 at P< 0.001, SWER the best cut-off value >4.9 with sensitivity, specificity, PPV, NPP and accuracy was 91.2%, 80%, 92.9%, 76.2%, 93.5%, respectively, and AUC= 0.890 at P< 0.001. The mean mass strain ratio for malignant lesions is 10.1 +/- 3.7 SD and for solid benign lesions 4.7 +/- 4.3 SD (p value 0.001). The mean shear wave elasticity ratio for malignant lesions is 10.6 +/- 5.4 SD and for benign (solid and cystic) lesions 3.6 +/- 4.2 SD. Using ROC curve and Youden index, the difference in diagnostic performance between ES, SR and SWER was not significant in differentiation between benign and malignant breast lesions and also was non-significant difference when comparing them with conventional US alone. Conclusion: ES, SR, and SWER have a high diagnostic performance in differentiating malignant from benign breast lesions with no statistically significant difference between them.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Morphological analysis of breast cystic lesions in shear wave elastography
    Rzymski, Pawel
    Opala, Tomasz
    WSPOLCZESNA ONKOLOGIA-CONTEMPORARY ONCOLOGY, 2011, 15 (04): : 208 - 212
  • [22] QUANTITATIVE ELASTOGRAPHY OF RECTAL LESIONS: THE VALUE OF SHEAR WAVE ELASTOGRAPHY IN IDENTIFYING BENIGN AND MALIGNANT RECTAL LESIONS
    Li, Tingting
    Lu, Man
    Li, Yuan
    Li, Juan
    Hu, Ziyue
    Li, Xu
    Cheng, Xueqing
    Jiang, Jingzhen
    Tan, Bo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (01): : 85 - 92
  • [23] Three-dimensional shear wave elastography for differentiation of breast lesions: An initial study with quantitative analysis using three orthogonal planes
    Wang, Qiao
    Li, Xiao-Long
    He, Ya-Ping
    Alizad, Azra
    Chen, Shigao
    Zhao, Chong-Ke
    Guo, Le-Hang
    Bo, Xiao-Wan
    Ren, Wei-Wei
    Zhou, Bang-Guo
    Xu, Hui-Xiong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2019, 71 (03) : 311 - 324
  • [24] The role of Shear-Wave elastography in the differentiation of benign and malign non-mass lesions of the breast
    Aslan, Hulya
    Pourbagher, Aysin
    Ozen, Merve
    ANNALI ITALIANI DI CHIRURGIA, 2018, 89 (05) : 385 - 391
  • [25] REDUCING UNNECESSARY BIOPSY OF BREAST LESIONS: PRELIMINARY RESULTS WITH COMBINATION OF STRAIN AND SHEAR-WAVE ELASTOGRAPHY
    Han, Jing
    Li, Fei
    Peng, Chuan
    Huang, Yini
    Lin, Qingguang
    Liu, Yubo
    Cao, Longhui
    Zhou, Jianhua
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (09): : 2317 - 2327
  • [26] Shear wave versus strain elastography of breast lesions-The value of incorporating boundary tissue assessment
    Tay, Ian Wei Ming
    Sim, Llewellyn Shao-jen
    Moey, Tammy Hui Lin
    Tan, Karen Pei Pei
    San Lai, Lily Mei
    Leong, Lester Chee Hao
    CLINICAL IMAGING, 2022, 82 : 228 - 233
  • [27] Comparison of qualitative and semiquantitative strain elastography in breast lesions for diagnostic accuracy
    Timothy Musila Mutala
    Purity Ndaiga
    Angeline Aywak
    Cancer Imaging, 16
  • [28] Evaluation of Different Types of Breast Lesions With Apparent Diffusion Coefficient and Shear Wave Elastography Values: Comparison of Shear Wave Elastography and Apparent Diffusion Coefficient in Breast Lesions
    Aybar, M. Devran
    Turna, Onder
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2022, 38 (05) : 420 - 428
  • [29] Comparison of qualitative and semiquantitative strain elastography in breast lesions for diagnostic accuracy
    Mutala, Timothy Musila
    Ndaiga, Purity
    Aywak, Angeline
    CANCER IMAGING, 2016, 16
  • [30] Shear-Wave Elastography of the Breast: Value of a Quality Measure and Comparison with Strain Elastography
    Barr, Richard G.
    Zhang, Zheng
    RADIOLOGY, 2015, 275 (01) : 45 - 53