DETERMINATION OF BIOACTIVE VOLATILE ORGANIC COMPONENTS OF LIPPIA CITRIODORA USING ULTRASONIC ASSISTED WITH HEADSPACE SOLID PHASE MICROEXTRACTION COUPLED WITH GC-MS

被引:0
|
作者
Meshkatalsadat, Mohammad Hadi [1 ,2 ]
Papzan, Abdoul Hamid [3 ]
Abdollahi, Ali [4 ]
机构
[1] Lorestan Univ, Dept Chem, Fac Sci, Khorramabad, Iran
[2] Qom Univ Technol, Fac Basic Engn Sci, Qom, Iran
[3] Razi Univ Technol, Dept Agron, Fac Agr, Kermanshah, Iran
[4] Univ Sistan & Baluchestan, Dept Med Plants, Fac Agr & Nat Resource, Saravan, Iran
关键词
Lippia citriodora; essential oil; HS-SPME; GC-MS; ESSENTIAL OILS; EXTRACTION; BRITTON;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this study the chemical composition of the essential oil extracted from fresh leaves of Lippia citriodora (Verbenaceae) using ultrasonic assist with headspace solid phase microextraction (UA-HS-SPME) combined with GC and GC-MS determined in full bloom. The highest extraction efficiency was achieved with a 100 mu m polydimethylsiloxane (PDMS) fiber. Different experimental parameters such as fiber's coating type, sonication time, extraction time and temperature, and desorption time were investigated. As a result, 15 constituents, representing 93.07% of the oil, were identified. Comparison of the UA-HS-SPME and the commonly used HD method showed that the UA-HS-SPME method is simpler and require smaller samples and shorter extraction times in addition to the greater ease of trapping and extracting the volatile and thermo-sensitive compounds. Also, GC-MS analysis of essential oils revealed that 1, 8-Cineole l (23.66%), a-curcumene (14.83%), Geranial (13.74%), limonene (13.40%) and caryophyllene oxide (6.60%) were the main components of essential oils of L. citriodora, respectively.
引用
收藏
页码:319 / 323
页数:5
相关论文
共 50 条
  • [41] Using Solid Phase Microextraction (SPME) and Person Portable GC-MS for Trace Level Detection of Selected Volatile Organic Chemicals in Air
    Sadowski, Charles S.
    Brande, Tiffany C.
    Later, Douglas W.
    LC GC NORTH AMERICA, 2013, : 20 - 20
  • [42] Critical comparison of automated purge and trap and solid-phase microextraction for routine determination of volatile organic compounds in drinking waters by GC-MS
    Lara-Gonzalo, Azucena
    Enrique Sanchez-Uria, Jose
    Segovia-Garcia, Eva
    Sanz-Medel, Alfredo
    TALANTA, 2008, 74 (05) : 1455 - 1462
  • [43] Volatiles fingerprint of Artemisia umbelliformis subsp eriantha by headspace-solid phase microextraction GC-MS
    Reale, Samantha
    Pace, Loretta
    D'Archivio, Angelo Antonio
    De Angelis, Francesco
    Marcozzi, Giordana
    NATURAL PRODUCT RESEARCH, 2014, 28 (01) : 61 - 66
  • [44] Analysis of Volatile Compounds in the Pericarp of Zanthoxylum bungeanum Maxim. by Ultrasonic Nebulization Extraction Coupled with Headspace Single-Drop Microextraction and GC-MS
    Wang, Lu
    Wang, Ziming
    Li, Xueyuan
    Zhang, Huihui
    Zhou, Xin
    Zhang, Hanqi
    CHROMATOGRAPHIA, 2010, 71 (5-6) : 455 - 459
  • [45] Headspace Solid-Phase Microextraction Coupled with Gas Chromatography–Mass Spectrometry for the Determination of Volatile Organic Compounds in Urine
    Małgorzata Natalia Drabińska
    Urszula Starowicz
    Journal of Analytical Chemistry, 2020, 75 : 792 - 801
  • [46] Comparison of Simultaneous Distillation and Extraction, Static Headspace and Headspace-Solid Phase Microextraction Coupled with GC/MS to Measure the Flavour Components of Tricholoma matsutake
    Chen, Xuan Qin
    Wang, Qian Qian
    Li, Jun Ming
    Wang, Ya Qin
    Zhang, Xue Zhong
    Li, Kun Zhi
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (11) : 6059 - 6063
  • [47] Analysis of volatile aroma compounds from five types of Fenghuang Dancong tea using headspace-solid phase microextraction combined with GC-MS and GC-olfactometry
    Li, Z. W.
    Wang, J. H.
    INTERNATIONAL FOOD RESEARCH JOURNAL, 2021, 28 (03): : 612 - 626
  • [48] Optimization of headspace sampling using solid-phase microextraction for volatile components in tobacco
    Yang, SS
    Huang, CB
    Smetena, I
    JOURNAL OF CHROMATOGRAPHY A, 2002, 942 (1-2) : 33 - 39
  • [49] Determination of non halogenated solvents in industrial wastewater using solid phase microextraction (SPME) and GC-MS
    López-Grimau, V
    Guadayol, JM
    Griera, JA
    Gutiérrez, MC
    LATIN AMERICAN APPLIED RESEARCH, 2006, 36 (01) : 49 - 55
  • [50] Optimization of solid-phase microextraction methods for GC-MS determination of terpenes in wine
    Peña, RM
    Barciela, J
    Herrero, C
    García-Martín, S
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2005, 85 (07) : 1227 - 1234