Reduced Graphene Oxide-based Sensor for 17α-ethinylestradiol Voltammetric Determination in Wastewater, Tablets and Synthetic Urine Samples

被引:9
|
作者
Monteiro, Michael Douglas S. [1 ,2 ]
Sant'Anna, Mercia V. S. [1 ,2 ]
Santos, Jose C., Jr. [1 ,2 ]
Macedo, Jose F. [1 ,2 ]
Alves, Anderson A. C. [2 ]
Silva, Jonatas de Oliveira S. [1 ,2 ]
Gimenez, Iara F. [1 ,2 ]
Sussuchi, Eliana Midori [1 ,2 ]
机构
[1] Univ Fed Sergipe, Programa Posgrad Quim, Dept Quim, BR-49100000 Sao Cristovao, SE, Brazil
[2] Univ Fed Sergipe, Grp Pesquisa Sensores Eletroquim & Nano Mat SEnM, Lab Corrosao & Nanotecnol LCNT, Nucleo Competencia Petr & Gas Sergipe NUPEG, BR-49100000 Sao Cristovao, SE, Brazil
关键词
Electrochemical sensor; Emerging pollutant; Hormone; Contraceptive; Estrogen; Endocrine disruptor; ELECTROCHEMICAL DETECTION; MODIFIED ELECTRODES; ETHINYLESTRADIOL; COMPOSITES; REDUCTION; BIOSENSOR;
D O I
10.1002/elan.202100500
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The following study reports the development of modified electrode with reduced graphene oxide (ErGO) for the voltammetric determination of 17 alpha-ethinylestradiol (EE2). The structural and morphological characterizations of the rGO were carried out by FTIR, Raman, UV-Vis, TEM and SEM, and showed the typical formation of the nanomaterial. Electrochemical analyses were performed using Differential Pulse Voltammetry (DPV). Under optimized conditions, an analytical curve was generated for the sensor, which presented a linear dynamic range (LDR) from 0.04 to 8.28 mu mol L-1 (R-2=0.9999), with limit of detection (LOD) of 6.79 nmol L-1 and limit of quantification (LOQ) of 22.60 nmol L-1. The reproducibility and repeatability studies showed relative standard deviations (RSD) of 2.31 % and 5.23 %, respectively. ErGO was used to determine EE2 in wastewater, tablets, and synthetic urine samples with recovery values between 94.8 % and 110.1 %. The results obtained with ErGO show that the developed sensor can be used for the identification and quantification of EE2 in several matrices, due the excellent analytical performance presented.
引用
收藏
页码:1422 / 1430
页数:9
相关论文
共 50 条
  • [21] Enhanced voltammetric sensing platform based on gold nanorods and electrochemically reduced graphene oxide for As(III) determination in seafood samples
    Pichun, Bryan
    Nunez, Claudia
    Arancibia, Veronica
    Marti, Angel A.
    Aguirre, Maria J.
    Pizarro, Jaime
    Segura, Rodrigo
    Flores, Erick
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (07) : 1595 - 1606
  • [22] A graphene oxide-based electrochemical sensor for sensitive determination of 4-nitrophenol
    Li, Junhua
    Kuang, Daizhi
    Feng, Yonglan
    Zhang, Fuxing
    Xu, Zhifeng
    Liu, Mengqin
    JOURNAL OF HAZARDOUS MATERIALS, 2012, 201 : 250 - 259
  • [23] Chemically reduced graphene oxide-based dry electrodes as touch sensor for electrocardiograph measurement
    Das, Partha Sarati
    Hossain, Md Faruk
    Park, Jae Yeong
    MICROELECTRONIC ENGINEERING, 2017, 180 : 45 - 51
  • [24] A simple and efficient voltammetric sensor for dopamine determination based on ZnO nanorods/electro-reduced graphene oxide composite
    Li, Fuzhi
    Ni, Beibo
    Zheng, Yiru
    Huang, Yunxia
    Li, Guangli
    SURFACES AND INTERFACES, 2021, 26
  • [25] Reduced graphene oxide-based gas sensor array for pattern recognition of DMMP vapor
    Alizadeh, Taher
    Soltani, Leyla Hamed
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 234 : 361 - 370
  • [26] A one-step electrochemically reduced graphene oxide based sensor for sensitive voltammetric determination of furfural in milk products
    Wang, Qiuqiu
    Zhang, Juanhua
    Xu, Yanbo
    Wang, Yingyi
    Wu, Liang
    Weng, Xuexiang
    You, Chunping
    Feng, Jiuju
    ANALYTICAL METHODS, 2021, 13 (01) : 56 - 63
  • [27] A voltammetric sensor based on electrochemically reduced graphene modified electrode for sensitive determination of midecamycin
    Xi, Xia
    Ming, Liang
    ANALYTICAL METHODS, 2012, 4 (09) : 3013 - 3018
  • [28] Picomole determination of vanillin in infant formula by molecularly imprinted polypyrrole nanowires/reduced graphene oxide-based electrochemical sensor
    Feng, Yujue
    Guo, Hongyuan
    Zhang, Guojuan
    Zhu, Yingchun
    Wu, Suozhu
    MICROCHEMICAL JOURNAL, 2024, 205
  • [29] Eco-Friendly Elaborated Clay-Supported Reduced Graphene Oxide for the Determination of Antibacterial Ciprofloxacin in Wastewater, Urine, and Drug Samples
    Azriouil, M.
    Chhaibi, B.
    Hrioua, A.
    Laghrib, F.
    Farahi, A.
    Bakasse, M.
    Lahrich, S.
    EL Mhammedi, M. A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (11)
  • [30] Reduced graphene oxide-based chemiresistive NO2 sensor: metal oxide nanoparticles decoration effect
    Bag, Atanu
    Moon, Dong-Bin
    Lee, Nae-Eung
    2023 IEEE SENSORS, 2023,