Comparison of hydroxyapatite-coated and uncoated pins for transfixation casting in horses

被引:5
|
作者
Lescun, Timothy B. [1 ]
Baird, Debra K. [1 ]
Oliver, Laurinda J. [1 ]
Adams, Stephen B. [1 ]
Hawkins, Jan F. [1 ]
Moore, George E. [1 ]
机构
[1] Purdue Univ, Coll Vet Med, Dept Vet Clin Sci, W Lafayette, IN 47907 USA
关键词
EXTERNAL-FIXATION PINS; 3RD METACARPAL BONE; SKELETAL FIXATION; FRACTURE FIXATION; TRACT INFECTION; STRENGTH; INTERFACE; TOPOGRAPHY; PROSTHESES; FRICTION;
D O I
10.2460/ajvr.73.5.724
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To determine the extent to which a hydroxyapatite coating promotes pin stability in the third metacarpal bone during transfixation casting in horses. Animals-14 adult horses. Procedures-7 horses each were assigned to either an uncoated or hydroxyapatite-coated pin group. Three transcortical pins were placed in the third metacarpal bone of each horse and incorporated into a cast for 8 weeks. Insertion and extraction torque were measured, and torque reduction was calculated. Radiography was performed at 0, 4, and 8 weeks. Lameness evaluation was performed at 2, 4, 6, and 8 weeks. Bacteriologic culture of pins and pin holes was performed at pin removal. Results-All horses used casts without major complication throughout the study. Insertion torque was higher in uncoated pins. There was no effect of group on extraction torque. Hydroxyapatite-coated pins had lower torque reduction. Five of 15 hydroxyapatite-coated pins maintained or increased stability, whereas all uncoated pins loosened. Pin hole radiolucency, lameness grades, and positive bacteriologic culture rates were not different between groups. Conclusions and Clinical Relevance-Hydroxyapatite coating increased pin stability within the third metacarpal bone of horses during 8 weeks of transfixation casting but did not improve pin performance on clinical assessments. Clinical use of hydroxyapatite-coated transfixation pins may result in greater pin stability; however, further research is necessary to improve the consistency of pin osteointegration and elucidate whether clinical benefits will ultimately result from this approach in horses. (Am J Vet Res 2012;73:724-734)
引用
收藏
页码:724 / 734
页数:11
相关论文
共 50 条
  • [21] X-ray diffraction of bone at the interface with hydroxyapatite-coated versus uncoated metal implants
    Savarino, L
    Stea, S
    Granchi, D
    Donati, ME
    Cervellati, M
    Moroni, A
    Paganetto, G
    Pizzoferrato, A
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (02) : 109 - 115
  • [22] X-ray diffraction of bone at the interface with hydroxyapatite-coated versus uncoated metal implants
    L SAVARINO
    S STEA
    D GRANCHI
    M. E DONATI
    M CERVELLATI
    A MORONI
    G PAGANETTO
    A PIZZOFERRATO
    Journal of Materials Science: Materials in Medicine, 1998, 9 : 109 - 115
  • [23] Improving fixation strength in osteoporotic wrist fracture patients with hydroxyapatite-coated external fixation pins
    Moroni, A
    Faldini, C
    Marchetti, S
    Manca, M
    Consoli, V
    Giannini, S
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S13 - S13
  • [24] Hydroxyapatite-coated Schanz pins inexternal fixators used for distraction osteogenesis -: A randomized, controlled trial
    Pommer, A
    Muhr, G
    Dávid, A
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (07): : 1162 - 1166
  • [25] Fixation strength of tapered versus bicylindrical hydroxyapatite-coated external fixation pins: An animal study
    Moroni, A
    Faldini, C
    Pegreffi, F
    Giannini, S
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (01): : 61 - 64
  • [26] Comparison of hydroxyapatite-coated non-hydroxyapatite-coated noncemented total hip arthroplasty in same patients
    Lee, Joong-Myung
    Lee, Churl-Woo
    JOURNAL OF ARTHROPLASTY, 2007, 22 (07): : 1019 - 1023
  • [27] BONE INGROWTH ANALYSIS AND INTERFACE EVALUATION OF HYDROXYAPATITE-COATED VERSUS UNCOATED TITANIUM POROUS BONE IMPLANTS
    MORONI, A
    CAJA, VL
    SABATO, C
    EGGER, EL
    GOTTSAUNERWOLF, F
    CHAO, EYS
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (6-7) : 411 - 416
  • [28] Morphological analysis of hydroxyapatite-coated external fixation pins removed from osteoporotic trochanteric fracture patients
    Pegreffi, F
    Maltarello, MC
    Mosca, M
    Romagnoli, M
    Moroni, A
    Giannini, S
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S25 - S25
  • [29] Longitudinal comparison between hydroxyapatite-coated and pure titanium implants.
    Imbronito, AV
    Todescan, FF
    Tortamano, P
    Lotufo, RFM
    Pustiglioni, FE
    Todescan, JH
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1191 - 1191
  • [30] Biomechanical analysis of hydroxyapatite-coated external fixation pins removed from osteoporotic trochanteric fracture patients
    Pegreffi, F
    Romagnoli, M
    Moroni, A
    Giannini, S
    BIOCERAMICS 16, 2004, 254-2 : 651 - 653