A 2D/3D US/CT-guided system for percutaneous focal liver thermal ablation

被引:0
|
作者
Xing, Shuwei [1 ,2 ]
Cool, Derek W. [4 ]
Gardi, Lori [1 ]
Bax, Jeffrey [1 ]
Chen, Elvis C. S. [1 ,2 ,4 ,5 ]
Peters, Terry M. [1 ,2 ,3 ,4 ]
Fenster, Aaron [1 ,2 ,3 ,4 ]
机构
[1] Western Univ, Robarts Res Inst, London, ON, Canada
[2] Western Univ, Sch Biomed Engn, London, ON, Canada
[3] Western Univ, Dept Med Biophys, London, ON, Canada
[4] Western Univ, Dept Med Imaging, London, ON, Canada
[5] Lawson Hlth Res Inst, London, ON, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
3D US; percutaneous thermal ablation; calibration; multimodality registration; liver ablation;
D O I
10.1117/12.2612085
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Image-guided percutaneous thermal ablations are promising techniques for the treatment of focal liver tumors. Conventionally, 2D ultrasound (US)-guidance is used extensively to assist liver tumor treatment. Recently, 3D US imaging has attracted much attention as its provided volumetric information can better help physicians interpret and localize liver structures. However, 3D US imaging still has the same limitation as conventional 2D US imaging in visualizing ultrasonically invisible cases. To address this issue, the current mainstream solution is to provide real-time 2D US-CT/MRI registered images by leveraging external tracking systems, such as electromagnetic (EM) or optical approaches. Due to their inevitable constraints, such as the presence of ferromagnetic structures in the case of EM tracking systems, or the line-of-sight limitation for optical systems, whether these solutions can be readily applied to the clinic has been under investigation. In this paper, we aim to investigate the feasibility of a 3D US-based ablation paradigm using our developed 2D/3D US/CT-guided liver ablation system. To achieve this goal and provide accurate guidance for ablation procedures, we proposed a local-and-global calibration method to track our mechatronic guidance arm. We also used a fiducial-based registration method to align 3D US with diagnostic CT images and implemented the re-slicing function to display the CT image corresponding to the US transducer's pose. Results demonstrated the feasibility of our system to visualize the complementary information from multiple image modalities in real time. Our calibration method can provide accurate tracking with an unsigned error of 1.6 mm +/- 0.4 mm. This work is a step towards providing a system to guide the liver ablation procedure, including cases with ultrasonically invisible or poorly visible tumors.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] 3D US-Based Evaluation and Optimization of Tumor Coverage for US-Guided Percutaneous Liver Thermal Ablation
    Xing, Shuwei
    Romero, Joeana Cambranis
    Cool, Derek W.
    Mujoomdar, Amol
    Chen, Elvis C. S.
    Peters, Terry M.
    Fenster, Aaron
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (11) : 3344 - 3356
  • [2] Robotic system for accurate percutaneous puncture guided by 3D–2D ultrasound
    Yanping Lin
    Shihang Chen
    Wangjie Xu
    Xiaoxiao Zhu
    Qixin Cao
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 217 - 225
  • [3] 3D US-CT/MRI registration for percutaneous focal liver tumor ablations
    Xing, Shuwei
    Romero, Joeana Cambranis
    Roy, Priyanka
    Cool, Derek W.
    Tessier, David
    Chen, Elvis C. S.
    Peters, Terry M.
    Fenster, Aaron
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (07) : 1159 - 1166
  • [4] 3D US-CT/MRI registration for percutaneous focal liver tumor ablations
    Shuwei Xing
    Joeana Cambranis Romero
    Priyanka Roy
    Derek W. Cool
    David Tessier
    Elvis C. S. Chen
    Terry M. Peters
    Aaron Fenster
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 1159 - 1166
  • [5] Intra-procedural evaluation of tumor coverage using 3D US images for percutaneous focal liver thermal ablation
    Xing, Shuwei
    Romero, Joeana Cambranis
    Cool, Derek W.
    Mujoomdar, Amol
    Leite, Leandro Cardarelli
    Chen, Elvis C. S.
    Peters, Terry M.
    Fenster, Aaron
    [J]. MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [6] C-arm CT-guided 3D navigation of percutaneous interventions
    Becker, H-C
    Meissner, O.
    Waggershauser, T.
    [J]. RADIOLOGE, 2009, 49 (09): : 852 - 855
  • [7] Tumour Coverage Evaluation for Percutaneous Liver Tumour Ablations: 2D US vs 3D US
    Xing, Shuwei
    Cool, Derek W.
    Chen, Elvis C. S.
    Peters, Terry M.
    Fenster, Aaron
    [J]. MEDICAL PHYSICS, 2022, 49 (08) : 5641 - 5641
  • [8] Development of a 3D Ultrasound-Guided System for Thermal Ablation of Liver Tumors
    Neshata, Hamid R. S.
    Cool, Derek W.
    Barker, Kevin
    Gardi, Lori
    Kakani, Nirmal
    Fenster, Aaron
    [J]. MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [9] Lung Thermal Ablation: Comparison between an Augmented Reality Computed Tomography (CT) 3D Navigation System (SIRIO) and Standard CT-Guided Technique
    Grasso, Rosario Francesco
    Andresciani, Flavio
    Altomare, Carlo
    Pacella, Giuseppina
    Castiello, Gennaro
    Carassiti, Massimiliano
    Quattrocchi, Carlo Cosimo
    Faiella, Eliodoro
    Zobel, Bruno Beomonte
    [J]. BIOLOGY-BASEL, 2021, 10 (07):
  • [10] Augmented reality 3D navigation system for percutaneous CT-guided pulmonary ground-glass opacity biopsies: a comparison with the standard CT-guided technique
    Faiella, Eliodoro
    Messina, Laura
    Castiello, Gennaro
    Bernetti, Caterina
    Pacella, Giuseppina
    Altomare, Carlo
    Andresciani, Flavio
    Sarli, Marina
    Longo, Filippo
    Crucitti, Pierfilippo
    Zobel, Bruno Beomonte
    Grasso, Rosario Francesco
    [J]. JOURNAL OF THORACIC DISEASE, 2022, 14 (02) : 247 - 256