Early Outcomes of Revision Surgery for Taper Corrosion of Dual Taper Total Hip Arthroplasty in 187 Patients

被引:32
|
作者
Dimitriou, Dimitris [1 ]
Liow, Ming Han Lincoln [1 ]
Tsai, Tsung-Yuan [1 ]
Leone, William A. [2 ]
Li, Guoan [1 ]
Kwon, Young-Min [1 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Orthopaed Surg, 55 Fruit St, Boston, MA 02114 USA
[2] Holy Cross Hosp, Orthoped Ctr, Dept Orthopaed Surg, Ft Lauderdale, FL USA
来源
JOURNAL OF ARTHROPLASTY | 2016年 / 31卷 / 07期
关键词
revision total hip arthroplasty; taper corrosion; clinical outcomes; modular femoral neck stem; dual taper; systematic evaluation; LOCAL TISSUE REACTION; MODULAR-NECK; FEMORAL IMPLANTS; FOLLOW-UP; METAL; PSEUDOTUMOR; RESURFACINGS; REPLACEMENT; STEMS;
D O I
10.1016/j.arth.2016.01.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Modular dual taper femoral neck designs have been associated with taper corrosion requiring revision surgery. However, outcomes after revision dual taper total hip arthroplasty in patients with symptomatic adverse local tissue reaction due to taper corrosion remain largely unknown. Methods: A total of 198 revision surgeries in 187 patients with dual taper femoral stem total hip arthroplasty with minimum 12-month follow-up were evaluated. Results: At mean follow-up of 18 months, at least 1 complication had occurred in 39 patients (20%) of 198 revisions. Single episode of dislocation, treated with close reduction, occurred in 16, whereas 2 patients required rerevision due to multiple dislocations. Infection requiring rerevision occurred in 3 patients. Adverse local tissue reaction recurrence requiring reoperation occurred in 6 patients. Implant survivorship for revision for any cause was 86% at 30 months. The reoperation rate of revised dual taper was 8% (16 out of 198 hips). The median serum levels of cobalt, chromium, and cobalt/chromium ratio decreased (P < .01) from 5.3 mu g/L (range: 2.3-48.5 mu g/L), 2.6 mu g/L (range: 0.2-64 mu g/L), and 4.7 (range: 2.1-35) prerevision to 1.4 mu g/L (range: 0.2-8.8 mu g/L), 0.7 mu g/L (range: 0.1-3.9 mu g/L), and 2.2 (range: 0.4-8.8) postrevision, respectively. Conclusion: This pilot study demonstrates that intraoperative tissue necrosis was associated with a high rate of early complications (20%) and revisions (8%), suggesting the importance of a systematic evaluation of these patients including metal ion levels and metal artifact reduction sequence magnetic resonance imaging in optimizing revision outcome, as early diagnosis will facilitate the initiation of appropriate treatment before significant adverse tissue necrosis. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1549 / 1554
页数:6
相关论文
共 50 条
  • [31] REVISION SURGERY IN TOTAL HIP-ARTHROPLASTY
    GALANTE, JO
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1983, (177) : 304 - 304
  • [32] Revision total hip arthroplasty - Indications and outcomes
    Mahomed, N
    Katz, JN
    ARTHRITIS AND RHEUMATISM, 1996, 39 (12): : 1939 - 1950
  • [33] Dual mobility for total hip arthroplasty revision surgery: A systematic review and metanalysis
    Giacomo, Placella
    Giulia, Bettinelli
    Valerio, Pace
    Vincenzo, Salini
    Pierluigi, Antinolfi
    SICOT-J, 2021, 7
  • [34] Dual Mobility for Total Hip Arthroplasty Revision Surgery: A Systematic Review and Metanalysis
    Antinolfi, P.
    Pace, V.
    Placella, G.
    Bettinelli, G.
    Salini, V.
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [35] Outcomes of Modular Dual Mobility Acetabular Components in Revision Total Hip Arthroplasty
    Sutter, E. Grant
    McClellan, Taylor R.
    Attarian, David E.
    Bolognesi, Michael P.
    Lachiewicz, Paul F.
    Wellman, Samuel S.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (09): : S220 - S224
  • [36] Letter to the Editor: In Response to "Modular Taper Junction Corrosion and Failure: How to Approach a Recalled Total Hip Arthroplasty Implant"
    Davies, Joseph F.
    Leone, William A.
    Nessler, Joseph P.
    Perona, Paul G.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 449 - 450
  • [37] Clinically significant corrosion at the head-neck taper interface in total hip arthroplasty: a systematic review and case series
    Carli, Alberto
    Politis, Angelos
    Zukor, David
    Huk, Olga
    Antoniou, John
    HIP INTERNATIONAL, 2015, 25 (01) : 7 - 14
  • [38] Volumetric material loss in metal-on-metal total hip arthroplasty: Bearing surface wear versus taper corrosion
    Hexter, A.
    Matthies, A.
    Bills, P.
    Skinner, J.
    Hart, A.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 42 - 42
  • [39] Validating a Simplified Method for Assessing Total Hip Arthroplasty Taper Corrosion Susceptibility with a 15-Year Retrieval Database
    Aldinger, Patrick
    Cartner, Jacob
    Jones, Bob
    MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 : 113 - 131
  • [40] How to Proceed with Asymptomatic Modular Dual Taper Hip Stems in the Case of Acetabular Revision
    Grupp, Thomas M.
    Baxmann, Marc
    Jansson, Volkmar
    Windhagen, Henning
    Heller, Karl-Dieter
    Morlock, Michael M.
    Knaebel, Hanns-Peter
    MATERIALS, 2020, 13 (05)