Computed Tomography to Cone Beam Computed Tomography Deformable Image Registration for Contour Propagation Using Head and Neck, Patient-Based Computational Phantoms: A Multicenter Study

被引:10
|
作者
Loi, Gianfranco [1 ]
Fusella, Marco [2 ]
Vecchi, Claudio [3 ]
Menna, Sebastiano [4 ]
Rosica, Federica [5 ]
Gino, Eva [6 ]
Maffei, Nicola [7 ,8 ]
Menghi, Enrico [9 ]
Savini, Alessandro [9 ]
Roggio, Antonella [2 ]
Radici, Lorenzo [10 ]
Cagni, Elisabetta [11 ,12 ]
Lucio, Francesco [13 ]
Strigari, Lidia [14 ]
Strolin, Silvia [15 ]
Garibaldi, Cristina [16 ]
Romano, Chiara [16 ]
Piovesan, Marina [17 ]
Franco, Pierfrancesco [18 ]
Fiandra, Christian [18 ,19 ]
机构
[1] Univ Hosp Maggiore della Carita, Dept Med Phys, Novara, Italy
[2] Veneto Inst Oncol IOV IRCCS, Med Phys Dept, Padua, Italy
[3] Tecnol Avanzate, Turin, Italy
[4] Fdn Policlin Univ A Gemelli IRCCS, Dipartimento Diagnost Immagini Radioterapia Oncol, UOC Fis Sanitaria, Rome, Italy
[5] ASL Teramo, UOC Fis Sanitaria, Teramo, Italy
[6] AO Ordine Mauriziano Torino, SC Fis Sanitaria, Turin, Italy
[7] AOU Modena, Dept Med Phys, Modena, Italy
[8] Univ Turin, Post Grad Sch Med Phys, Turin, Italy
[9] IRCCS, Ist Sci Romagnolo Studio & Cura Tumori IRST, Med Phys Dept, Meldola, FC, Italy
[10] Osped Reg Umberto Parini Azienda USL VDA, Fis Sanitaria, Bologna, Italy
[11] Azienda USL IRCCS Reggio Emilia, Med Phys Unit, Reggio Emilia, Italy
[12] Cardiff Univ, Sch Engn, Cardiff, Wales
[13] ASLCN2 Alba & Bra, Alba, Italy
[14] St Orsola Malpighi Hosp, Dept Med Phys, Bologna, Italy
[15] INI Citta Bianca, Radiotherapy Unit, Veroli, FR, Italy
[16] European Inst Oncol IRCCS, Unit Med Phys, IEO, Milan, Italy
[17] UOC Fis Med ULSS 3 Serenissima, Venice, Italy
[18] Univ Turin, Dept Oncol, Turin, Italy
[19] Politecn Torino, Sch Bioengn & Med Surg Sci, Turin, Italy
关键词
ADAPTIVE RADIATION-THERAPY; RADIOTHERAPY; CT; VALIDATION; PERFORMANCE; ALGORITHMS; ACCURACY; MODEL; TOOL; RT;
D O I
10.1016/j.prro.2019.11.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the performance of various algorithms for deformable image registration (DIR) for propagating regions of interest (ROIs) using multiple commercial platforms, from computed tomography to cone beam computed tomography (CBCT) and megavoltage computed tomography. Methods and Materials: Fourteen institutions participated in the study using 5 commercial platforms: RayStation (RaySearch Laboratories, Stockholm, Sweden), MIM (Cleveland, OH), VelocityAI and SmartAdapt (Varian Medical Systems, Palo Alto, CA), and ABAS (Elekta AB, Stockholm, Sweden). Algorithms were tested on synthetic images generated with the ImSimQA (Oncology Systems Limited, Shrewsbury, UK) package by applying 2 specific deformation vector fields (DVF) to real head and neck patient datasets. On-board images from 3 systems were used: megavoltage computed tomography from Tomotherapy and 2 kinds of CBCT from a clinical linear accelerator. Image quality of the system was evaluated. The algorithms' accuracy was assessed by comparing the DIR-mapped ROIs returned by each center with those of the reference, using the Dice similarity coefficient and mean distance to conformity metrics. Statistical inference on the validation results was carried out to identify the prognostic factors of DIR performance. Results: Analyzing 840 DIR-mapped ROIs returned by the centers, it was demonstrated that DVF intensity and image quality were significant prognostic factors of DIR performance. The accuracy of the propagated contours was generally high, and acceptable DIR performance can be obtained with lower-dose CBCT image protocols. Conclusions: The performance of the systems proved to be image quality specific, depending on the DVF type and only partially on the platforms. All systems proved to be robust against image artifacts and noise, except the demon-based software. (C) 2019 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
  • [21] Quantitative evaluation of a cone beam computed tomography (CBCT)-CT deformable image registration method for adaptive radiation therapy
    Lawson, J. D.
    Schreibmann, E.
    Jani, A. B.
    Fox, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S709 - S709
  • [22] Evaluation of 4-dimensional Computed Tomography to 4-dimensional Cone-Beam Computed Tomography Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy
    Balik, Salim
    Weiss, Elisabeth
    Jan, Nuzhat
    Roman, Nicholas
    Sleeman, William C.
    Fatyga, Mirek
    Christensen, Gary E.
    Zhang, Cheng
    Murphy, Martin J.
    Lu, Jun
    Keall, Paul
    Williamson, Jeffrey F.
    Hugo, Geoffrey D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (02): : 372 - 379
  • [23] Cone Beam Computed Tomography to assess pitch, roll and rotation in Head and Neck Radiotherapy
    Thornberry, D.
    McLauchlan, R.
    Gujral, D. M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S1061 - S1061
  • [24] Metal Artifact Reduction in Cone-Beam Computed Tomography for Head and Neck Radiotherapy
    Korpics, Mark
    Johnson, Paul
    Patel, Rakesh
    Surucu, Murat
    Choi, Mehee
    Emami, Bahman
    Roeske, John C.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : NP88 - NP94
  • [25] Image-guided radiotherapy for liver cancer using respiratorycorrelated computed tomography and cone-beam computed tomography
    Guckenberger, Matthias
    Sweeney, Reinhart A.
    Wilbert, Juergen
    Krieger, Thomas
    Richter, Anne
    Baier, Kurt
    Mueller, Gerd
    Sauer, Otto
    Flentje, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : 297 - 304
  • [26] Student learning of head and neck anatomy using cone beam computed tomography and immersive virtual reality
    Kim-Berman, Hera
    Bui, Duy
    Lee, Katelyn
    Mitchell, Vanessa
    Bonine, Brandon
    Benavides, Erika
    Soki, Fabiana
    Ramaswamy, Vidya
    JOURNAL OF DENTAL EDUCATION, 2023, 87 (08) : 1180 - 1187
  • [27] Virtual surgical planning and cone beam computed tomography in reconstruction of head and neck tumors - pilot study
    Krakowczyk, Lukasz
    Piotrowska-Seweryn, Agnieszka
    Szymczyk, Cezary
    Wierzgon, Janusz
    Oles, Krzysztof
    Ulczok, Rafal
    Donocik, Karolina
    Dowgierd, Krzysztof
    Maciejewski, Adam
    POLISH JOURNAL OF OTOLARYNGOLOGY, 2021, 75 (02): : 28 - 32
  • [28] Prevalence of soft tissue calcifications in the head and neck region: A cone-beam computed tomography study
    Yalcin, E. D.
    Ararat, E.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2020, 23 (06) : 759 - 763
  • [29] The effect of registration volumes on residual errors assessed using cone-beam computed tomography in radiation treatment of head and neck cancer
    Lohnson, L.
    Waldron, J.
    Dawson, L.
    Bayley, A.
    Cummings, B.
    Kim, J.
    O'Sullivan, B.
    Ringash, J.
    Pintilie, M.
    Breen, S. L.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S65 - S66
  • [30] Evaluation of the Interchangeability of Cone Beam Computed Tomography and Catalyst for Patient Positioning in Radiotherapy for Head and Neck Cancer Patients
    Hewala, Taha I.
    Fahmy, Mohamed A.
    Elbenhawy, Sanaa A.
    Ammar, Hany M.
    MIDDLE EAST JOURNAL OF CANCER, 2024, 15 (02) : 128 - 135